SLV 1000339 Ceiling Light Instruction Manual

June 10, 2024
SLV

SLV 1000339 Ceiling Light

Product Information

This product is a ceiling light with model number 1000339. It is rated IP44 for outdoor use and has a maximum diameter of 7.5cm. It requires an approved electrician for installation and should only be installed in accordance with local and national regulations. The product should be operated with intact protection glass and should be taken out of service when suspecting a defect or malfunction.
The product uses GX53 light sources with a maximum wattage of 11W.

Product Usage Instructions

Safety Advices:

  • Read the manual carefully and keep it for further use.
  • Any works on the electrical connection should only be done by an approved electrician.
  • Do not alter or modify the product, fasten anything on it, or cover it.
  • Operate the product only with intact protection glass.
  • Take measures to ensure that children are not harmed by the product.

Lamp Replacement:

  1. Disconnect the luminaire from mains and let it cool down.
  2. Use only suitable light sources with a maximum wattage of 11W.
  3. Clean the gasket if it becomes dirty.

Care and Storage:

  • Disconnect the product from mains and let it cool down before cleaning.
  • Clean external surfaces regularly with a slightly moistened (water) cloth. Do not clean with a pressure washer.
  • Keep openings for aeration or drainage free.
  • Avoid exposing the product to acidic surroundings, high salt content in the air, cleaning agents, fertilizer, thawing salt, or chemicals.
  • Store the product in a dry and clean place.

Installation

  1. Switch off mains/fixed connection cable.
  2. Use only described accessories and suitable fastening materials.
  3. Install according to declared IP type and as shown in the figure.
  4. Direct the fixed wiring with its complete insulation at least 15mm into the housing.
  5. Equip flexible wire ends with suitable wire ferrules.
  6. Check for secure fixation and proper function.

Packing

INSTRUCTION MANUAL PART A

Ceiling Light

The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!

Disposal (European Union)
Do not dispose the product with the regular household waste! Products marked with this sign must be disposed according to the directive (WEEE) on electrical and electronic devices at local collection points for such devices!
Waste batteries and accumulators, which are not enclosed by the waste equipment, and lamps, which are removable nondestructive from the waste equipment are to be separated nondestructive from the waste equipment before turning to a local collection point.
Distributors are, according to particular legislation, obligated to take back waste equipment from the final holder.
It lies in the personal responsibility of the final holder to delete personal data before the disposal.
For disposal the waste equipment may be send to the following address:

Operating Manual PART B

Ceiling Light
1000339

Read manual carefully and keep for further use!

Safety advices for installation and operation.
Disregard may lead to danger of life, burning or fire!
Any works on the electrical connection only by electrician.
Do not alter or modify the product.
Do not fasten anything on the product.
Do not cover the product.
Operate only with intact protection glass.
Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
Take measures that children get not harmed by the product.
Additional safety advices =

Use as directed

  • Safety class I (1) – Connection with protective conductor.
  • Operate only firmly fixed on an even surface.
  • Operate only on normal or not inflammable surfaces.
  • Do not strain mechanically or expose to strong dirt contamination.
  • IP44: Protection against foreign objects > Ø 1,0mm – Protection against splashing water from all directions.

Care / Storage
Disconnect product from mains and let it cool down.
Clean external surfaces regularly with a slightly moistened (water) cloth.
Do not clean with pressure washer.
Openings providing aeration or drainage must be kept free.
The following influences may have unwanted effects on the product: acidic surrounding, high salt content in the air, cleaning agents, fertilizer, thawing salt, chemicals.
Store dry and clean.

Installation

Switch off mains / fixed connection cable!
Use only described accessories.
Use only suitable fastening materials.
Only suited for ceiling surface mounting.
Follow local regulations for outdoor installations.
Do not seal the product yourself (e.g. with silicone).
Install according to declared IP type.
Install as shown in the figure.

Electrical connection

Direct the fixed wiring with its complete insulation at least 15 mm into the housing.
Equip flexible wire ends with suitable wire ferrules!
Live conductor Terminal L
Neutral conductor Terminal N
Protective conductor Earth terminal

Check secure fixation and proper function!

SLV UK
Unit E Chiltern Park
Boscombe Road, Bedfordshire
LU5 4LT

© 04.05.2022 SLV GmbH, Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany, Tel. +49 (0)2451 4833-0. Made in China.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals