universal douglas LVLBP34-90 LED Linear Pendant Light Installation Guide
- June 3, 2024
- universal douglas
Table of Contents
LVLBP34-90 LED Linear Pendant Light
Installation Guide
LED LINEAR PENDANTLIGHT
IMPORTANT SAFETY INSTRUCATION
Read this installation guide prior to attempting installation.Always turn OFF
the main power before starting your installation. Consult a qualified
electrician before installation. Installation should be carried out by a
qualified eletrician.
During installation, basic safety precautions should always be followed,
including the following listed.
- Do not install the lighting system in a wet location.
- Ensure the appropriate connectors match the luminaire fixture
- Do not install any part of the luminaire less than 5 feet above the floor.
- Do not install any luminaire assembly closer than 5 inches from any window treatments,i.e.,curtain, blinds or any similar combustible type material.
- Do not attempt to energize anything other than the luminaire fixtures.
- To reduce the risk of fire and electric shock,do not attempt to connect to power tools, extension cords, appliances, or the like, to the track.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires construction and any hazards involved. regular fixture maintenance programs are recommended.
- Do not exceed the nominal supply voltage or amperage ratings.
- Turn the power OFF at the fuse or circuit breaker box before doing any installation or maintenance activities.
- Wear rubber soled shoes and work on a sturdy wooden or non-conductive ladder.
- The lighting product must be mounted in locations and at heights in compliance with the National Electrical Code and with local building codes. Installing contrary to instruction may cause unsafe conditions.
- To avoid hazards to children, take accountability for all parts and dispose all packing materials properly.
- It may be necessary to clan the refractor / lens.Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to the user. Refractor / lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor / lens and clean in above manner, replacing damaged gaskets as necessary.
- Call the Technical Support department about any installation questions.
- Do not install a damaged product. This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm.Any part damaged or broken during or after assembly should be replaced.
- These instructions do no purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation or maintenance.Should further information be desired or particular problems arise,not covered sufficiently for the purchaser’s or owner’s purposes, please contact the Technical Team.
LVLBP34-90 LED Linear Pendant Light
CATION
This equipmen is intended to be installed only by qualified personnel.
The installation must be made in accordance with the current edition of the
National Electrical Code (NEC) and all applicable state and local building
codes. The final installation must be approved by the appropriate, qualified
electrical / building inspector(s). Improper installation may result in a fire
or electrical hazard. Ensure the electrical power to the circuit has been
disconnected before installing the electrical system
WARNING
- Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°
- Consult a qualified electrician before installation.
- Properly ground electrical enclosure.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet meal or other sharp objects.
- Use only UL approved wire input/output connections.Minimum size 18 AWG or 14AWG if there are any continuous runs.
- If the fixtures are connected in a continuous run, do not exceed allowable number of fixtures in series/power in continuous runs.
- Inrush currents must be taken in account by the electricians to account for proper circuit design.
TOOL
A1) Rope Suspension Installation
Drill a hole of 5.0mm in diameter at the location required for installation. Then install the plastic anchor to the hole with hammer.
No. | Size | A(in) | B(in) |
---|---|---|---|
1 | 2FT | 22.21 | / |
2 | 4FT | 45.83 | / |
3 | 6FT | 69.45 | / |
4 | 8FT | 46.54 | 46.5 |
Insert PA430 Screws into the screw holder and then drill into the plastic anchor.Lock the steel wire rope pedestal to the ends plates with PM48 screws.Press down the inner hole of the steel wire rope pedestal, let the steel wire rope go through the hole.
Connect L,N,GND,DIM+ and DIM- of AC input wire to L,N,GND, DIM+and DIM- respectively of AC terminal.Press the to pend of the steel wire rope pedestal to adjust the steel wire rope,and then finish the installation.
A2) Canopy Suspension Installation
Drill a hole of 5.0mm in diameter as shown in the figure at the location required for installation. Then hammer the plastic anchor into the hole.
N0. 1 | Size | A(in) | B(in) | C(in) | D(in) | E(in) |
---|---|---|---|---|---|---|
1 | 2ft | 3.346 | 18.9 | 3.35 | / | / |
2 | 4ft | 3.346 | 42.5 | 3.35 | / | / |
3 | 6ft | 3.346 | 66.1 | 3.35 | / | / |
4 | 8ft | 3.346 | 43.2 | 3.35 | 43.2 | 3.35 |
Insert PA4*30 screws into the M type mounting bracket and then drill into the plastic anchor.
Lock the steel wire rope pedestal to the ends plates with PM4*8 Screws.
Press down the inner hole of the steel wire rope pedestal, let the steel wire rope go through the hole.The thread locker passes through the canopy and is fixed with a screw nut, and the waterproof connector passes through the gasket and the canopy, and is fixed with a screw nutPress the steel wire rope holder as shown in the figure, and then insert the stainless steel wire into the inner hole of the steel wire rope holder; The mounting height of the lamp could be adjusted by this steel wire rope holder.Pass the AC into the waterproof connector, fix the AC wire with a screw cap, connect the L pole to the black wire, the N pole to the white wire, the GND to the green wire, the DIM+ pole to the purple wire, and the DIM- pole to the pink wire
Adjust the length of the AC input cable, align the side hole of the canopy and the M mounting bracket as shown in the figure, then tighten the screw.
B.Linkable Instruction
Note:Only available for Linkable Products.
Measure the ceiling , make down the position for lineae1, install the first Linear Light to the ceiling as instruction of A Rope Suspension Installation.
No. | Size | A(in) | B(in) | C(in) | D(in) | Remark |
---|---|---|---|---|---|---|
1 | 2FT | 22.920 | 23.630 | 22.920 | / | 3pcs linkable diagrammatic drawing |
2 | 4FT | 46.540 | 47.250 | 46.540 | / | 3pcs linkable diagrammatic drawing |
3 | 6FT | 70.160 | 70.870 | 70.160 | / | 3pcs linkable diagrammatic drawing |
4 | 8FT | 46.540 | 47.250 | 47.250 | 46.540 | 2pcs linkable diagrammatic drawing |
Install Linear 1, then connect AC line; remove one end cap as show on (2-b)
Lift up the up-light module as the picture shows.Insert the linkable bracket into the Linear1,connect with buckle inside the Linear1,take out the inside linkable wire. ( Five color)Insert the Linear Light as Step 2 and adjust the steel wire rope in the same height. Then Move out two end caps of Linear2,lift up the up light module, disconnect the AC wire. keep the female plug to the side endsConnect the male plug of Linear 1 and female plug of Linear2, insert the bracket to the Linear 2 make them seamless linkable together.Check the status after linked make sure no any gap between two linears.
Make sure the male and female plugs have been connected well,press down the uplight module, put it back to the top of Linear1 and Linear2
Install the Linear Light 3,4,5,6 and7 as above method,keep one main input cord on one side for wiring andg rounding Adjust the steel wrie rope inthe same height. Then finish the installation.
NOTE:LED LINEAR CAN BE GAPLESS LINKABLE TOGETHER AS NEEDED, ( if you order to use 18# cord,More Links can be Customized.)
Max. linkable Quantity (Unit:PC) Linkable fixtures Qty need t o meet the below
two conditions:
1)N<7pcs
2) Input voltage = 120V , NP<420W
Input voltage =347V , NP<960W
Note: N = Qty of linkable fixtures,
P = Wattage per fixture
C. Wall Mount
Installation Kits
1 | C Wall-mount Bracket | 1PC |
---|---|---|
2 | Square Decorative | 1 PC |
3 | L support | 2PCS |
4 | Plastic Anchor | 4PCS |
5 | Cross head tapping | 4PCS |
6 | Hand screw | 4PCS |
7 | Screw | 1PC |
8 | End cap | 2PCS |
9 | Linkable braket | 1 PC |
Drill Hole on the wall based on the Length of the Fixture, Fix the plastic anchor in the hole and fix the Wall Mount Bracket on the Wall.
Push the L support bracket into the wall mount bracket as followed.
Connect L, N, GND, DIM+ and DIM-
of AC input wire to L, N, GND, DIM+ and DIM- respectively of AC wire.
Get the linear light install into the wall mount bracket as followed picture.
Using the hand screw to secure the linear light.
Connect the quick connector between the linear light and connector from the AC power wire. After then, put it into the linear body.
Linkable fixtures Qty need to meet the below two conditions:
1)N<7pcs.
2)Input voltage = 120V , NP<420W
Input voltage = 347V , NP<960W
Note: N = Qty of linkable fixtures,
P= Wattage per fixture.
Linkable braket insert into one fixture , connect the male and female connector, the other part of linkable braket insert into the other fixuture. Then the fixture fixed on the wall mounted kit.
Install the end caps, the connector wire must get through the correct place on the end caps as followed picture.
Turn on the light.
D. Install MAS & Sensor
- Insert the purple cable into 1# hole, pink cable for “-“, red cable for “+”;
- Connect the male terminals to female from the lighting fixture;
- Connect the red cable to red cable from lighting fixture with nipple connector;
- Fix the sensor to MAS, and then fix the MAS to the lighting fixture by screws.
- Fix the pedestal with Aircraft ropes to the lighting fixture by M4*8mm Screws;
- Adjust the length of the suspending ropes, make balance of the lighting fixture.
- Connect the AC Input power cable to the lighting fixture: 3-wiring terminals, male to female.
- Fix the AC input power cable to the stuckable hole on the lighting fixture.
- Put the Upper Lighting modular back, and fix it to the lighting fixture.