universal douglas LR14T8-18L8xx-10DU-X LED T8 Tube and Driver Retrofit Instruction Manual
- October 27, 2023
- universal douglas
Table of Contents
INSTALLATION INSTRUCTIONS
LED T8 TUBE & DRIVER RETROFIT
14049200
SUITABLE FOR DRY OR DAMP LOCATIONS.
SAFETY WARNINGS
IMPORTANT SAFETY INFORMATION
DANER Risk of shock. Disconnect power before installation.
WARNiNG Risk of fire or electric shock. LED Retrofit Assembly
installation requires knowledge of luminaires electrical systems. If not
qualified, do not attempt installation. Product must be installed in
accordance with NEC or your local electrical code. If you are not familiar
with these codes and requirements, contact a qualified electrician.
WARNiNG Risk of fire or electric shock. To prevent wiring damage or
abrasion, do not expose wires to the edge of sheet metal or any other sharp
objects.
WARNiNG Risk of fire or electric shock. Check the existing wiring for
damage before Installing upgrade assembly. Do not install if existing wires
are damaged.
WARNlNG Risk of fire or electric shock. Luminaire wiring and electrical
parts may be damaged when drilling for installation of the LED upgrade
assembly.
Check for enclosed wiring and components.
Risk of fire or electric shock. Install this assembly only in luminaires that
WARNING have the construction features and dimensions shown in the
photographs and/or drawings.
Do not make or alter any open holes in an enclosure of wiring or electrical
components during kit installation.
NOTE. THE RETROFIT ASSEMBLY IS ACCEPTED AS A CON- PONENT OF A LUMINAIRE
WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES
HAVING JURISDICTION.
LED DRIVER COMPATIBILITY REQUIREMENTS
Qty of
Lamps| Kit Part Number| Driver| Rating| Input
Voltage| Drivers Catalog#
---|---|---|---|---|---
Current| Voltage
1| LR14T8-18L8xx-10DU-X| 290mA| 42V min| 120-277V| D700C2OUNVPWX12-C
LR14T8-18L8xx-10DU-XCT
| LR24T8-36L8xx-10DU-X| 590mA| 42V min| 120-277V| D10CC3OUNVPWX12-C
LR24T8-36L8xx-10DU-XCT
3| LR34T8-54L8xx-10DU-X| 890mA| 42V min| 120-277V| D15CC55UNVPWX12-C
LR34T8-54L8xx-10DU-XCT
3| LR44T8-72L8xx-10DU-X| 1190mA| 42V min| 120-277V| D15CC55UNVPWX12-C
LR44T8-72L8xx-10DU-XCT
xx: 35/3500K, 40/4000K, 50/5000K
Module p/n: LRT8M22L/8xxA
Bluetooth Control:
Included with models having the CT suffix Catalog #: BT-LRT-A Models without
the CT suffix have 12V auxiliary power but no control included.
INSTALLATION
For installation in lensed or parabolic 2’ x 2’ or 2’x4’ troffers. Type IC
(Insulated Ceiling) or type Non-IC, 40°C max ambient. Requires minimum 3”
depth.
For installation in 4ft or 8ft Vaportight: Lensed, minimum 5” depth and 6.75”
width, 40°C max ambient.
One retrofit kit per luminaire.
Step 1: Disconnect the power to the fixture.
Step 2: Remove existing lamps, ballast cover plate, and ballast. Leave
existing wire in place and as long as possible. Replace lamp holders if
necessary.
Step 3: Verify that the luminaire is connected to the ground wire from the AC
supply.
Step 4: Secure the Universal Douglas driver into the fixture. Use a self-
tapping screw (not provided) if necessary.
Step 5: Connect existing leads to the driver as shown. The lamps are connected
and operated in parallel for both ends of the lamps. Wires should be 18AWG
solid conductor with %” strip length.
Step 6: Connect the BT-LRT-A controller and mount it adjacent to the LED
tubes, outside of the ballast wiring channel in recessed troffers.
Step 7: Insert the line and neutral wires into their connectors.
Step 8: Replace the ballast cover plate, take care not to pinch wires.
Step 9: Insert the lamps with the label side facing the back of the fixture.
Step 10: Place relamp label at a visible location in the fixture. Close or
replace lens and secure latches or other fastening means.
Step 11: Restore power and confirm lamps are operating properly.
BT-LRT-A INSTALLATION
The sensor has a magnet which allows for it to be mounted to the metal tray or
panel of the luminaire. The BT-LRT-A be mounted within the ballast channel
where it is completely enclosed in metal. The leads of the BT-LRT-A are to be
connected to the driver as shown in the wiring diagram.
For installation outside of the wiring channel of the fixture the leads should
be routed away from the input power leads and not come in contact with the
power leads. Leads should exit the end of the channel and the sensor be
placed between lamps.
CONNECTION DIAGRAMS
www.universaldouglas.com Rev. 3/15/22
Universal Lighting Technologies
Documents / Resources
|
universal douglas LR14T8-18L8xx-10DU-X LED T8 Tube and Driver
Retrofit
[pdf] Instruction Manual
LR14T8-18L8xx-10DU-X, LED T8 Tube and Driver Retrofit, LR14T8-18L8xx-10DU-X
LED T8 Tube and Driver Retrofit, T8 Tube and Driver Retrofit, Tube and Driver
Retrofit, Driver Retrofit
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>