VIAIR 45043 450p Automatic Portable Compressor User Manual
- June 13, 2024
- VIAIR
Table of Contents
- VIAIR 45043 450p Automatic Portable Compressor
- IMPORTANT SAFETY INSTRUCTIONS
- OPERATING INSTRUCTIONS
- SAFETY PRECAUTIONS
- MAINTENANCE & REPAIRS
- INLET AIR FILTER INSTALLATION INSTRUCTION
- TROUBLESHOOTING GUIDE
- SPECIFICATIONS
- LIMITED WARRANTY
- CONTACT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VIAIR 45043 450p Automatic Portable Compressor
IMPORTANT SAFETY INSTRUCTIONS
CAUTION: To reduce risk of electrical shock or electrocution:
- Do not disassemble. Do not attempt repairs or modifications.
- Refer to qualified service agencies for all service and repairs.
- Do not use this product in or area where it can fall or be pulled into water or other liquids.
- Do not reach for this product if it has fallen into liquid.
- Use this compressor with 12-Volt DC systems only.
- This product should never be left unattended during use.
WARNING: To prevent injury:
- Never allow children to operate this compressor.
- Close supervision is necessary when this compressor is being used near children.
- This compressor will become very HOT during and immediately after use.
- Do not touch any part of this compressor with bare hands, other than the ON/OFF switch during and immediately after use.
- Do not use this product near flames or explosive materials or where aerosol products are being used.
- Do not operate this product where oxygen is being administered.
- Do not pump anything other than atmospheric air.
- Never use this product while sleepy or drowsy.
- Do not use any tools or attachments without first determining maximum air pressure for that tool or attachment.
- Never point any air nozzle or air sprayer toward another person or any part of the body.
- This air compressor is equipped with an Automatic Reset Thermal Protector, and can automatically restart after the thermal protector resets. Always cut off power source when thermal protector becomes activated.
- Wear safety glasses or goggles when operating this product.
- Use only in well ventilated areas.
- After usage, always release excess pressure from the coil hose by turning On/Off switch to the Off position, disconnect hose from compressor, with the tire inflation gun still connected to the other end of the coil hose, pull trigger on the tire inflation gun to release excess pressure.
OPERATING INSTRUCTIONS
Please read and follow the operating instructions carefully to assure that you will enjoy the convenience and best use out of your air compressor.
- Always operate the compressor AT OR BELOW THE MAXIMUM PRESSURE RATING of the compressor. Refer to Specifications section of this manual.
- Always OBSERVE THE MAXIMUM DUTY CYCLE of the air compressor. Refer to Specifications section of this manual for details. Operations exceeding maximum pressure ratings and or duty cycle will result in damage to air compressor.
- Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR. This feature is designed to protect the air compressor from over-heating and causing permanent damage to your air compressor. The thermal overload protector will automatically cut off power to air compressor should internal operating temperature of the air compressor rise above safe levels during excessive use.
- Should your compressor shut off suddenly after extended use, do not attempt to restart air compressor. Turn ON/OFF switch of air compressor to the OFF position. The automatic thermal overload protector will automatically reset when internal temperature of the air compressor drops below safe level. After allowing air compressor to cool off for about 30 minutes, you can safely resume use of the air compressor by turning on the air compressor.
- For your convenience, and to protect the air compressor from over-pressure operation that can cause permanent damage to the unit – this compressor is equipped with built-in pressure switch with a factory set cut-on pressure of 130 PSI (± 5%) and a factory set cut-off pressure of 155 PSI (± 5%). During inflation of tire pressures between 130 PSI to 155 PSI, if you stop inflation, the compressor may not restart. This is completely normal, since inline pressure is greater than cut-on pressure of the pressure switch and less than cut-off pressure of the pressure switch. To restart compressor, deflate tire pressure to below 130 PSI, reconnect tire chuck to tire valve stem and resume tire inflation. 6. Please note that you may experience a slight delay of the compressor’s motor starting when the ON/OFF switch is turned on while compressor is pressurized (when there is pressure in the line that the compressor is connected to). This is a normal delayed reaction, not a Compressor ON/OFF switch malfunction.
- It is strongly recommended that you keep the vehicle’s engine running while using the air compressor to prevent discharge of your vehicle’s battery.
- ONLY OPERATE THE AIR COMPRESSOR IN WELL VENTILATED AREAS. Compressor performance is enhanced when operating compressor with vehicle engine running.
IMPORTANT: Engine must be running while using this compressor.
Before attaching air compressor power clamps to your vehicle’s battery
terminals, check to make sure that the ON\/OFF switch of your compressor is in
the OFF position. Attach the Positive (+) battery clamp (Red) to the Positive
terminal of the battery and the Negative (-) battery clamp (Black) to the
Negative terminal of the battery. Always keep your vehicle’s engine running
while operating compressor to avoid draining your vehicle’s battery.
CAUTION: Your Portable Air Compressor is Moisture and Dust Resistant, but
NOT WATER OR DUST PROOF. Never place compressor in soft sand while running the
compressor. Vibration from the compressor will cause the compressor to settle
into soft sand, resulting in compressor drawing in foreign particles. Never
expose compressor to water while running the compressor.
This air compressor comes with 1/4″ quick connect stud. An extension coil hose and a tire inflation gun are also included with your compressor. Each end of the extension coil hose is equipped with a 1/4″ quick connect coupler. The tire inflation gun comes with a 1/4″ quick connect stud, pressure gauge, rubber hose, bleeder valve and tire chuck. Attach one end of the extension coil hose to the stud on your compressor and the other end to the stud on the tire gun kit. The tire gun kit can be used for both airing up and airing down. Please familiarize yourself with the following functions of this versatile air tool:
TIRE INFLATION
- Attach one end of the extension coil hose to the compressor and the other end to the tire gun kit.
- Push the tire chuck, with the lever in the upright position, down over the tire valve stem and then push the lever down to the horizontal position to lock in place.
- Turn compressor switch on and hold down the trigger on the tire gun kit to begin inflation.
- When desired pressure is reached, release the trigger and turn power switch on compressor off.
NOTE: To release excess pressure, turn off compressor and disconnect hose
from compressor. With the tire inflation gun still connected to the other end
of the coil hose, pull trigger on the tire inflation gun to release excess
pressure.
CAUTION: To avoid over inflation, never exceed recommended pressure on
articles to be inflated. Bursting can cause serious injury.
NOTE: Your air compressor is equipped with a pressure switch (cut in at
130 PSI, cut out at 155 PSI). This feature is designed to protect the air
compressor from over-pressure causing permanent damage to your air compressor.
The pressure switch automatically turns off the motor when the internal
pressure of the air compressor reaches the factory set “cut-out” pressure (155
PSI) and restarts when the internal pressure drops below 130 PSI.
TIRE DEFLATION
- Push the tire chuck (with the lever in the upright position) down over the tire valve stem and then push the lever down to the horizontal position to lock in place.
- Press the bleeder valve button on the tire gun kit to decrease tire pressure.
- When desired pressure is reached, release the bleeder valve button to halt deflation.
IMPORTANT: Make sure compressor sits upright while operating compressor.
Do not operate compressor in any other position. Avoid tugging at compressor
to move it. Instead, move compressor to the same side of vehicle as tires that
are being aired up.
Always make sure the Portable Compressor’s power cord is uncoiled and fully
extended when using your air compressor to avoid overheating the power cord.
INLINE PRESSURE GAUGE
- The pressure gauge on the inflation gun provides convenient tire pressure monitoring when airing up or down (not airflow of the compressor). This eliminates switching back and forth between a tire chuck and a tire pressure gauge.
- Please note that during inflation and deflation, due to air velocity, pressure gauge cannot provide accurate pressure readings. Release lever on the tire inflation gun during inflation to check tire air pressure.
NOTE: To release excess pressure, turn off compressor and disconnect hose from compressor. With the tire inflation gun still connected to the other end of the coil hose, pull trigger on the tire inflation gun to release excess pressure.
SAFETY PRECAUTIONS
- Always inflate tires to manufacturer’s recommended tire pressures. Exercise extreme caution when driving with aired-down tires. Reinflate tires before high-speed roadway travel.
- Never exceed 20 M.P.H. when driving with partially inflated tires.
- Never make sharp turns while driving with reduced tire pressure.
- Re-inflate tires before high speed traveling onto roadways.
- Use heat-resistant, minimum 200 PSI rated working pressure extension hose. Do not use aftermarket hoses with less than 200 PSI working pressure. Some aftermarket hoses may not be suitable for use with this air compressor due to heat and pressure typically generated by this type of air compressors.
CAUTION: Never touch the air compressor or fittings connected to the air compressor other than the ON/OFF switch with bare hands during or immediately after use. The extension hose and fittings connected extension hose will become very HOT during and after use. If necessary, wear heat resistant gloves to remove hose from the compressor quick connect stud.
MAINTENANCE & REPAIRS
- Your air compressor is equipped with permanently lubricated, maintenance-free motor.
- Never try to lubricate the compressor. Regularly clean dust and dirt from compressor cooling fins and motor housing. All repairs should be performed by Manufacturer or Manufacturer authorized service agencies only.
INLET AIR FILTER INSTALLATION INSTRUCTION
- Check to make sure air filter element is properly installed in your Inlet Air Filter Assembly
- Remove the temporary protective red plug from compressor’s air inlet port.
- Install inlet air filter onto compressor’s air inlet port. (Thread tape Not Recommended).
- Hand tighten inlet air filter.
IMPORTANT: For optimal compressor performance, replace filter element periodically. Clogged filter will drastically reduce compressor flow rate and performance.
TROUBLESHOOTING GUIDE
PROBLEM: POSSIBLE CAUSE(S) CORRECTIVE ACTION
Compressor will not run| 1. No power, or power switch in OFF position
2. Blown fuse
3. Motor overheats
| 1. Make sure compressor switch is ON
2. Disconnect compressor from power source, replace fuse. (Refer to Specifications section for correct fuse amperage)
3. Let compressor cool off for about 30 minutes to allow thermal overload switch to reset.
---|---|---
Thermal overload protector cuts out repeatedly| 1. Lack of proper ventilation
or ambient temperature is too high
2. Compressor valves failed
| 1. Move compressor to well ventilated area, or area with lower ambient temperature
2. Service or replace compressor
Excessive knocking or rattling| 1. Worn bearing on eccentric or motor shaft
2. Cylinder or piston ring is worn
| 1. Service or replace compressor
Compressor air flow lower than normal, or cannot pump to higher pressures| 1.
Worn piston ring or inlet valve| 1. Service or replace compressor
SPECIFICATIONS
MODEL 450P AUTOMATIC SPECIFICATIONS
- Part No.: 45043 / 450P Automatic (CE Certified)
- Part No.: 45044 / 450P Automatic – Stealth Black (CE Certified)
- Motor Voltage: 12-Volt
- Motor Type: Permanent Magnetic
- Max. Working Pressure: 150 PSI*
- Max. Duty Cycle: 100% (Continuous)
- (Min. On/Off @ 72ºF & 100 PSI)
- Continuous Use @ 72ºF & 30 PSI: Continuous
- Max. Current Consumption: 23-Amps
- Fuse: 30-Amps
- In-line Pressure Gauge: 160 PSI *Tolerance: ± 3%
- Built-in Pressure Switch: 130 PSI On, 155 PSI Off
- Auto. Reset Thermal Protection: Yes
- Ingress Protection Rating: IP54
Do not exceed compressor’s max working pressure to prevent damage to the compressor.
LIMITED WARRANTY
- VIAIR® Corporation warrants this product, when properly installed and under normal conditions of use, to be free from defects in workmanship and materials for a period of one year from its original date of purchase. To receive warranty service or repair, please contact VIAIR® Corporation.
- Returns should be made within one year of the date of purchase, after a Return Goods Authorization (RGA) number has been assigned by VIAIR® Corporation. To obtain RGA, fax a copy of your receipt to 949-585-0188. For complete warranty details, please visit: www.viaircorp.com/warranty.
PLEASE NOTE
THIS WARRANTY COVERS PRODUCT DEFECTS ONLY; IT DOES NOT COVER INCIDENTAL OR
CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE.
This Manual is proprietary to VIAIR® Corporation and no ownership rights are
hereby transferred. No part of the Manual shall be used, reproduced,
translated, converted, adapted, stored in a retrieval system, communicated or
transmitted by any means, for any commercial purpose, including without
limitation, sale, resale, license, rental or lease, without the prior express
written consent of VIAIR. VIAIR® does not make any representations, warranties
or guarantees, express or implied, as to the accuracy or completeness of the
Manual. Users must be aware that updates and amendments will be made from time
to time to the Manual. It is the user’s responsibility to determine whether
there have been any such updates or amendments. Neither VIAIR® nor any of its
directors, officers, employees or agents shall be liable in contract, tort or
in any other manner whatsoever to any person for any loss, damage, injury,
liability, cost or expense of any nature, including without limitation
incidental, special, direct or consequential damages arising out of or in
connection with the use of the Manual.
CONTACT
- 15 EDELMAN
- IRVINE, CA 92618
- TEL: 949-585-0011
- FAX: 949-585-0188
- www.viaircorp.com
Read User Manual Online (PDF format)