universal douglas LRA4P-347V-1 LED Strip Fixture Retrofit Owner’s Manual

October 30, 2023
universal douglas

universal douglas LRA4P-347V-1 LED Strip Fixture Retrofit

universal-douglas-LRA4P-347V-1-LED-Strip-Fixture-Retrofit-
PRODUCT

Product Information

Mechanical:

The LRA4P-347V LED Retrofit Kit Assembly is a 4 or 8-foot retrofit kit that can be easily installed in existing fluorescent fixtures. It comes with a driver and LED strips that can be mounted on the existing fixture.

Optical:
The LRA4P-347V LED Retrofit Kit Assembly is available in 3500K, 4000K, and 5000K color temperatures with a Color Rendering Index (CRI) of 82. It has a nominal lumen output ranging from 5100 to 11500 lumens, depending on the model.

Electrical:
The LRA4P-347V LED Retrofit Kit Assembly requires an input voltage of 347V and comes with a driver set current ranging from 750mA to 1050mA, depending on the model. It has an input power ranging from 24W to 53W and has a power factor of >0.98 at max driver current.

Certifications:
The LRA4P-347V LED Retrofit Kit Assembly is FCC Title 47 CFR, Part 15, Class A certified.

Kit Includes:
The LRA4P-347V LED Retrofit Kit Assembly includes LED strips, a driver, and mounting hardware.

Ordering Guide:
The LRA4P-347V LED Retrofit Kit Assembly ordering code ID consists of:

  • LRA4P: Product Identifier
  • 14 or 28: Length of the retrofit kit in feet
  • HL8xx or ML8xx: LED type
  • 347: Input voltage
  • xx: Color temperature (35, 40, or 50 for 3500K, 4000K, or 5000K)
  • xxLC: Nominal lumens (30LC, 42LC, 50LC, 60LC, 70LC, or 85LC)

Product Usage Instructions

To use the LRA4P-347V LED Retrofit Kit Assembly, follow these steps:

  1. Turn off the power to the existing fluorescent fixture.
  2. Remove the existing fluorescent tubes and ballast from the fixture.
  3. Mount the LED strips on the fixture using the included mounting hardware.
  4. Connect the driver to the fixture’s electrical supply.
  5. Attach the LED strips to the driver.
  6. Turn on the power to the fixture and test the LED retrofit kit assembly.

Note: Please consult the factory for photometry information. The LRA4P- 347V LED Retrofit Kit Assembly’s lumen and LPW tolerance is +/-10%. The application and performance information is subject to change without notification.

INTRODUCTION

MECHANICAL

  • Retrofits 4ft or 8ft fluorescent strip fixtures to

LED

  • Fast and easy installation
  • No design or revised layout needed

OPTICAL

  • Diffuser provides broad, even light distribution
  • Three CCT options with CRI of 82

ELECTRICAL

  • 347VAC, 60 HZ
  • Equipped with 0-10V dimmable LED Driver
  • LED System efficacies exceeding 115 LPW

CERTIFICATIONS

  • UL Classified UL1598C (US & Canada)
  • Suitable for Dry or Damp locations

KIT INCLUDES

  • (1) or (2) LED lightbars pre-mounted
  • (1) LED Driver (0-10V) pre-mounted
  • (1) or (2) 4’ strip fixture panels
  • Wiring, mounting hardware, installation instructions

WARRANTY

Five (5) year limited warranty

ORDERING

 | Ordering Code ID| Catalog Number| Nominal

Lumens

| Input

Power (W)

| LPW| CRI| CCT| Input

Voltage

---|---|---|---|---|---|---|---|---
4-Foot| LRA4P14-HL8xx-347-70LC| LRA4P14-HL8xx-347| 7000| 53| 132| 82| 3500K, 4000K,

5000K

| 347V
LRA4P14-HL8xx-347-60LC| 6000| 44| 136
LRA4P14-ML8xx-347-42LC| LRA4P14-ML8xx-347| 4200| 34| 124| 82| 3500K, 4000K,

5000K

| 347V
LRA4P14-ML8xx-347-30LC| 3000| 24| 125
8-Foot| LRA4P28-HL8xx-347-12KC|

LRA4P28-HL8xx-347

| 11500| 85| 135|

82

|

3500K, 4000K,

5000K

|

347V

---|---|---|---|---|---|---|---|---
LRA4P28-HL8xx-347-10KC| 10000| 71| 141
LRA4P28-HL8xx-347-85LC| 8500| 60| 142
LRA4P28-HL8xx-347-70LC| 7000| 48| 146
LRA4P28-ML8xx-347-65LC| LRA4P28-HL8xx-347| 6400| 48| 133| 82| 3500K, 4000K,

5000K

| 347V
LRA4P28-ML8xx-347-50LC| 5100| 38| 134
Driver Set

Current (mA)


900
750
1050
750
1500

1240
1065
855
1500
1250

EXAMPLE : LRA4P28-HL840-347-85LC

ORDERING NOTES

  • xx = 35, 40, 50 for 3500K, 4000K, 5000K
  • Consult factory for photometry.
  • Application and performance information is subject to change without notification.
  • Lumen and LPW Tolerance of +/- 10%.

OPERATING DATA

L85 Lumen Maintenance: >60,000 hrs. at 40°C
Min. Starting Temp.: -30°C (-22°F)
Sound Rating: Class A
EMI/RFI FCC Title 47 CFR, Part 15, Class A
Power Factor: >0.98 at max driver current
THD: <20%
Input Power Frequency: 50/60 Hz

COMPONENTS

Catalog Number| LED Light Bar| Driver| Driver Programmable

Output Range

---|---|---|---
LRA4P14-ML8xx-347| LRL14-50L8xx-900CCL| D10CC30347PW-C| 1050mA to 750mA
LRA4P28-ML8xx-347| LRL14-50L8xx-900CCL| D15CC55347PW-C| 1500mA to 1250mA
LRA4P14-HL8xx-347| LRL14-70L8xx-900CCL| D15CC55347PW-C| 900mA to 625mA
LRA4P28-HL8xx-347| LRL14-70L8xx-900CCL| D21CC80347PW-C| 1500mA to 500mA

APPLICATION NOTES:

  • All LED Lensed Modules must be connected for proper operation.
  • Not for use with phase cut dimmers.
  • Suitable for 4′ or 8′ strip light: non-lensed, minimum wiring compartment dimensions 2.5″ depth and 2″ width

DIMENSIONS

LRA PANEL ASSEMBLY (1 OR 2 PER KIT)universal-douglas-LRA4P-347V-1-LED-
Strip-Fixture-Retrofit-FIG- \(2\)universal-douglas-LRA4P-347V-1-LED-Strip-Fixture-
Retrofit-FIG- \(3\)

Adjustable brackets (if needed)universal-douglas-LRA4P-347V-1-LED-Strip-
Fixture-Retrofit-FIG- \(4\)

Installation Notes:

Installers can choose to use the existing socket bars if they line up with the LRA4P panel.
Adjustable brackets can be used in lieu of the existing socket bars. These wrap around the ends of the strip housing and are attached with screws. The LRA panel mounts to these brackets with a ¼ turn thumb screw.

www.universaldouglas.com
Rev. 7/22/2022
Universal Lighting Technologiesuniversal-douglas-LRA4P-347V-1-LED-Strip-
Fixture-Retrofit-FIG- \(1\)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

universal douglas User Manuals

Related Manuals