Description: 4’ LED Lensed Module

  • Simple and easy installation
  • Long life with high efficacy
  • Diffuser lens provides broad, even light distribution
  • Integrated heat sink for cool operation
  • Class 2 rating simplifies wiring

Lumen Performance:

Catalog Number

| Nominal|

CRI

Current

(Amps)

| Initial

Lumens (1)

| Vf (2)

(Volts)

| Power

(Watts)

|

Lm/W

LRL14-30L840-750C

| 0.525| 2,435| 35| 18| 133| >82
0.700| 3,150| 36| 25| 125
1.050| 4,500| 38| 40| 113

  1. MID Flux Bin Values are shown for CCT of 4000K. Tolerance of ±6.5% at 25°C
  2. Vf is at Tc of 25°C with max tolerance of +/‐ 5%.

General Performance Specifications

  • Lumen Maintenance : L85 > 60Khrs (reported)
    L70 > 140Khrs (calculated)
    @ I= 1050mA, tamb=40°C

  • Color Consistency:
    <3 SDCM (3500K, 4000K)
    <4 SDCM (5000K)

Mechanical Dimensions

• Length: 42.46”
• Width 0.8”
• Height: 1.24”
• Weight: 1.4lbs
• Lead Length: Red & Blue 24”

Ordering Information

Part Number CCT Lumen Multiplier
LRL14-30L835-750C10C 3500K 97.%
LRL14-30L840-750C10C 4000K 100.%
LRL14-30L850-750C10C 5000K 104.%

Application:

• Min. Ambient Operating Temp.: ‐22°F, ‐30°C
• Max. Ambient Operating Temp.: 140°F 60°C
• Maximum Current rating of 1.05 Amps

Carton Quantity: 10

Regulatory

  • UL8750
  • CSA250.13‐14
  • RoHS Compliant

Notes:

  • Performance data were taken at Tamb = 25°C
  • Power consumption and photometric performance are typical values
  • Lumen maintenance value is based on LM80 testing and TM‐21 calculation projections.

universal douglas LRL14-30L840-750C 4’ LED Lensed Module - Figure
1

Installation & Assembly Guidelines

  • This module is to be mounted using mounting slots and fasteners. The aluminum frame should be grounded or mounted to a grounded metal surface.
  • Modules may be connected in parallel to split current from the LED driver.

Dimensions

24” 20AWG
Stranded
Copper Leads

universal douglas LRL14-30L840-750C 4’ LED Lensed Module - Figure
3

Application and operation performance specification information is subject to change without notification.

Application Notes:

  1. The standard base model version of this module without Conformal Coating is designed for indoor fixtures in dry applications. Damage caused by corrosion due to moisture, condensation, and other harmful elements, is not covered by the warranty.

Conditions of Acceptability

  1. The LED modules are intended for connection to a Class 2, constant current source of supply.
    The connection of the LED arrays to a source of supply other than class 2, the suitability must be determined in the end-use product investigation.

  2. The LED modules shall be installed in compliance with the mounting, spacing, casualty, and the segregation requirements applicable to the ultimate application.

  3. The LED modules were subjected to the Normal Temperature Test in a 40°C Ambient.
    | Maximum Input
    Current| Location
    Center of the PCB| Measured °C| Limit °C
    ---|---|---|---|---
    •LRL14-30Lyzz-aaaC| 1200 mA| Between 48’h and
    49th LED| 69.| 105
    Center – Bottom
    Heat Sink| 64.| —

  4. The LED Array modules are suitable for “DRY” locations. The use in other than dry locations shall be evaluated to the end-use application.

  5. The array modules may be marked with any voltage and current rating that does not exceed the maximum ratings specified in the ELECTRICAL RATINGS.

  6. Suitability of input connections to the LED module to be determined in the end-use product.

Application and operation performance specification information is subject to change without notification.