ROBUS RUL07X4-01 Ultimate 7W IP65 Fire Rated Downlight Instructions
- June 6, 2024
- ROBUS
Table of Contents
RUL07X4-01 Ultimate 7W IP65 Fire Rated Downlight
Instructions
PLEASE READ THE INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN THEM
FOR FUTURE REFERENCES.
! Electrical products can cause death or injury, or damage to property. If in
any doubt about the installation or use of this product, consult a competent
electrician
Note:
Product technical information and specification may change over time without
prior notification. For the latest technical information please visit our web
site www.robus.com or
robusdirect.com
-20°C < Ta < +40°C, 220-240V ~ 50/60Hz, Class I, IP65
Suitable for mounting on a normally flammable surface.
See website for compatible dimmer list: www.robus.com
Installation
-
Ensure mains supply is switched off before commencing work.
-
It is possible to change the trims to a different color
-
Before cutting, ensure that the hole does not impinge on joists, pipework, cables or other building services.
-
This luminaire requires a round hole of Ø72mm to be cut into the ceiling for correct installation.
-
Connect supply: L – Brown, N –Blue and Yellow/Green – Earth
-
Rotate to remove front trim. Move the switch to select color temperature: 2700K, 3000K, 4000Kor 6000K.
WARNING: DO NOT CHANGE CCT WHEN THE FITTING IS ON!! -
Hold retention spring vertically against the heat sink, push fitting through the cut-out until the springs come down on the upper side of the plasterboard. Ensure that the fitting is secure and the bezel is tight against the ceiling.
The luminaire may be covered with mineral wool thermal insulation of the type
described in EN 13162:2015. If the installer wishes to use loose insulation or
foam spray over insulation, they must use a bell-shaped insulation cover over
the luminaire. Although the fitting may be safely covered with insulation
material, we recommend that the luminaire be abutted to but not covered with
insulation material in order to maximize the lifetime of the luminaire.
Luminaire lifetime can be maximized by maintaining as low an operating
temperature as possible.
Trims accessories: RULSTRIM-03: Chrome; RULSTRIM-10: Matt Black;
RULSTRIM-13: Brushed Chrome.
Downlights listed are tested in 30, 60, and 90-minute ceiling types using EN
1365-2.2014 test method. For a list of tested ceiling types please contact
Robus Technical
Department. Minimum spacing of 500mm between downlights must be maintained or
no more than 2 downlights within a 1m² area.
Market Surveillance: LS Code of energy efficiency Class G. RUL07X4-SL
Use a flat head screwdriver to prise open driver housing. Remove screws and
remove the driver (SCG). Expose LED section(LS)
Information for the Product user:
- Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked with crossed-out wheelie bin symbol).
- Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection center for waste electrical equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.
- This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly. It is important that it is separated from normal household waste and recycled in the WEEE chain
- The “crossed out wheelie bin symbol” on a product indicates this equipment must not be disposed of in normal household waste, but should be disposed of according to local WEEE regulations
The Installation must be carried out by a qualified electrician
L.E.D lighting & Electrical Distribution Group UC
IRE: Nangor Road, Dublin 12, D12 E7VP, Ireland
UK: Bracknell Enterprise & Innovation Hub, Ocean
House, 12th Floor, The Ring, Bracknell,
Berkshire RG12 1AX, UK
Tel: +353 1 7099000
Fax: +353 1 7099060
Email: info@robus.com
Website: www.robus.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>