DELTA DORE TYXAL Floor Magnetic Contact Installation Guide
- June 1, 2024
- DELTA DORE
Table of Contents
DELTA DORE TYXAL Floor Magnetic Contact
Specifications:
- Model: LS 14250
- Voltage: 3.6 V
- Capacity: 1.2 Ah
- Battery Type: Lithium
- Dimensions: 33 x 102 x 32 mm
- Radio Power: < 10 mW
- IP Rating: IP 30
- IK Rating: IK 02
- Compliance: EN 50131-3, RTC 50131-3, EN 50131-6, RTC 50131-6, EN 50131-1 Grade 2
- Environmental Class: II
Product Usage Instructions
Important Product Information:
This product is a battery model LS 14250 with a voltage of 3.6 V and a capacity of 1.2 Ah. It is a lithium battery suitable for various applications.
Installation:
Refer to the system installation guide for detailed instructions on how to install the battery properly. Ensure to follow the guidelines provided to maximize the battery’s lifespan.
Activation:
- Switch SWA: ON
- Switch SWB: ON
- For operation with an alarm system, refer to the system installation guide for further instructions.
Maintenance:
Ensure to regularly check the battery status and replace it when necessary. Follow proper disposal guidelines for lithium batteries.
FAQ
- Q: What is the expected lifespan of the LS 14250 battery?
- A: The battery can last up to 10 years under specified usage conditions mentioned in the installation instructions and General Conditions of Sale.
- Q: What are the dimensions of the battery?
- A: The battery has dimensions of 33 x 102 x 32 mm.
- Q: What is the radio power output of the battery?
- A: The battery has a maximum radio power output of less than 10 mW.
More info
Specification
EN 50131-3 / RTC 50131-3 / EN 50131-6 / RTC 50131-6 / EN 50131-1 Grade 2 Environmental class II
- Important product information
- Up to 10 years valid under the conditions of use specified in the installation instructions and the General Conditions of Sale
Contents
Presentation
- The detector must be associated with a DELTA DORE wireless X3D alarm system
Location
- The floor contact door magnetic contact detector must be installed indoors and mounted on a garage door
Triggering distances (ferrous or non-ferrous mounts).
Tolerance for operating distances: +0% / -50%
- X: Magnet displacement left or right
- Y: Magnet displacement upwards or downwards
- Z: Magnet displacement forwards or backwards
Mounting
- Open the unit.
- Mark and drill holes D1 and D2.
- Attach the transmitter base with the V1 and V2 screws.
- Mount the sensor À) on the concrete floor and the magnetic part (Á) on the garage door
Activation
- Connect the white wire to AL, the yellow and brown wires to Com and the blue wire to AP.
- Insert the battery and close the unit
Switches
Switch B2 is used to select the triggering mode (ON: delayed, OFF: immediate).
- The other switches are not applicable (SWA1, SWA2 and SWB1).
- If your alarm system has a CLT 8000 touch-sensitive keypad, switch B2 will be ignored as this configuration is done on the keypad.
Operation with an alarm system
Changing the batteries
- Low batteries are indicated on the installation’s CLT 8000 touchscreen keypad.
- Before opening the unit, the alarm control unit must be in Maintenance mode (refer to the system installation guide).
- Once the low battery has been removed, wait a minute prior to inserting the new battery.