DELTA DORE RF 6420 Main Control Receiver For Boiler and Heat Exchanger Instruction Manual
- June 10, 2024
- DELTA DORE
Table of Contents
DELTA DORE RF 6420 Main Control Receiver For Boiler and Heat Exchanger
Product Information
The RE2020 is a product that allows for the installation of heating and air conditioning systems with or without Tywell Pro. The product comes in two options – RF 6420 and RF 6450. The maximum power of the radio is less than 10mW and the receiver category is 2. The product has a change-over feature and a thermostat input. The dimensions of the product are 54 x 102 x 25 mm. The product requires a 230V~ power supply at 50/60Hz with a maximum power of 1.8VA (RF 6420) and 2.6VA (RF 6450). The product can control up to 16 receivers with a maximum of 5A at 230V~.
Product Usage Instructions
- Select the heating or air conditioning mode on each Tywell Control in the installation.
- Use the Tydom application to select heating or cooling mode.
- Check that the generator is set to the desired mode.
- To pair the RF6000/RF6050 receiver with the RF6420/RF6450 receiver, press the button of each receiver for 3 seconds until its LED flashes and then release. Once the LED of both receivers stop flashing, they are paired.
- To unpair the RF6000/RF6050 receiver from the RF6420/RF6450 receiver, press the button of each receiver for 3 seconds until its LED flashes and then release. Once the LED of both receivers stop flashing, they are no longer paired.
Installations
Testing of installations equipped with a Change-Over.
Installations without Tywell Pro
- Select the heating or air conditioning mode on each Tywell Control in the installation
Installations with Tywell Pro
Use the Tydom application to select heating or cooling mode
Check that the generator is set to the desired mode.
- Hold down the receiver button for about 10 seconds:
- slow flashing for 3 seconds,
- fast flashing for 7 seconds. Release.
- Check that the receiver LED is no longer flashing.
The products are no longer associated.
Overview
Mounting
Connection
**Thermostat input
**
How to use
-
Switch on the installation.
Press the button of each RF6000 / RF6050 receiver for 3 seconds until its LED flashes. Release. -
Press the button of the RF6420 or RF6450 receiver for 3 seconds until its LED flashes.
Release. -
Check that the RF6000 / RF6050 LED is no longer flashing, as well as the LED of the RF6420 or 6450 receivers. The products are associated.