Delta Dore DU Tyxal Universal Radio Installation Guide
- June 15, 2024
- DELTA DORE
Table of Contents
DU Tyxal Universal Radio
Installation Guide
DU TYXAL +
www.deltadore.com
DU Tyxal Universal Radio
| LS 14250 – 3,6 V – 1,2 Ah – Lithium
---|---
|
| Consumption stand-by : 3,5 pA
Consumption : 14,2 mA max.
| X3D alarme : [868 – 868.6] MHz et [868.7 – 869.2] MHz 100 m , 300m Maximum
radio power < 10 mW, receiver category: 2
| -10°C / +70°C
| +5°C / +40°C
IP| IP 30 – IK 02
| 75%
| 33x 102 x 32 mm59 gr.
Environmental class I
Tam-per alarm on opening or removal of unit.
Important product information (0 0)
***** Up to 10 years valid under the conditions of use specifi ed in the installation instructions and the General Conditions of Sale
Contents
Presentation
The detector must be associated with a DELTA DORE wireless X3D alarm system.
Location
- The universal detector operates with a hard-wired sensor. Install the transmitter close to the sensor (cable length must not exceed 2 m).
- The universal detector must be installed indoors.
- Refer to the guide for the location and mounting of the sensor.
Fixation
- Open the unit.
- Mark and drill holes D1 and D2.
- Attach the transmitter base with the V1 and V2 screws.
Activation
-
Intruder: connect the intruder alarm wires to the AL and Com terminals, and the tamper alarm wires to the AP and Com terminals.
Other: connect the 2 wires of a sensor of your choice to the universal detector AL and Com terminals.
The AP terminal is not connected. -
Insert the battery and close the unit.
Switches
Switches SWA and SWB are used to configure the product.
| SWA 1 = ON
Technischer Alarm| SWA 1 = OFF
Intruder detection
---|---|---
__
__
__
SWA 2
| ON| OFF| ON| OFF
Normally closed| Normally open| Normally closed| Normally open
__
__
__
SWB
1
| | ON| OFF
Tamper alarm inactive| Tamper alarm active
__
__
__
SWB 2
| | ON| OFF
Delayed| Immediate
If your alarm system has a CLT 8000 touch sensitive keypad, switch SWB2 will be ignored as this configuration is done on the keypad.
Operation with an alarm system
- Association with an alarm system
- Selection of triggering mode
- Test
- Restoring factory settings
Refer to system installation guide
Changing the batteries
Low batteries are indicated on the installation’s CLT 8000 touchscreen keypad.
Before opening the unit, the alarm control unit must be in Maintenance mode
(refer to system installation guide).
Once the low battery has been removed, wait a minute prior to inserting the
new battery.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>