DELTA DORE TYXIA 4801 Wireless Micro Module Receiver Installation Guide

June 16, 2024
DELTA DORE

DELTA DORE TYXIA 4801 Wireless Micro Module Receiver

DELTA-DORE-TYXIA-4801-Wireless-Micro-Module-Receiver-
product

Product Information

Specifications

  • Model: TYXIA 4801 / 4811
  • Website: www.deltadore.com
  • TYXIA 4811: 230 V~, 50 Hz – 2 VA
  • TYXIA 4801: Class II
  • Maximum radio power: < 10 mW
  • Receiver category: 2
  • IP: IP40
  • Dimensions: 50 x 47 x 33mm
  • Power supply: 230 V~, 50/60 Hz
  • LED: LED

Product Usage Instructions

Operation / Operation / Funktionsweise / Funzionamento / Funcionamiento / Dzialanie / Werking

Local wired control / Local hard-wired control / Lokaler Schaltereingang / Comando filare locale / Mando filar local / Lokalne sterowanie kablowe / Lokale bedrade bediening

FAQs

  1. What is the maximum power of TYXIA 4811?
  2. What is the IP rating of the product?
  3. Can the local control wires be extended?

Specification And Features

8 light bulbs max.

DELTA-DORE-TYXIA-4801-Wireless-Micro-Module-Receiver-
fig-3....

  1. 230 V halogen or 230 V incandescent bulbs
  2. 230V energy-saving compact fluorescent bulbs
  3. LED-Lampe 230 V
  4. Very low voltage 12V halogen or LED bulbs with AC or DC electronic transformer
  5. Very low voltage 12V halogen bulbs with ferromagnetic or toroidal transformer

Location

Behind the existing switch

Operation

ON / OFF

  • Timed operation
  • Manual override
  • Warning that lighting is about to go off

DELTA-DORE-TYXIA-4801-Wireless-Micro-Module-Receiver-
fig-5 DELTA-DORE-TYXIA-4801-Wireless-
Micro-Module-Receiver-fig-7

  1. Timed operation initiated when ON is actuated.
  2. Timed operation initiated at end of detection.
  3. Phase Presence -> ON. The timed operation runs when the live is no longer present.
  4. Lights go out for 30’’, then 20’’ before they go out completely.
  5. Detection will be active only if it lasts more than 80 sec.

Connection

DELTA-DORE-TYXIA-4801-Wireless-Micro-Module-Receiver-
fig-8

  • A  Any unconnected wire must be insulated (connecting block).
  • B IMPORTANT, the control wires are not mains-isolated. Any equipment recorded must be marked CE and comply with the requirements of low-voltage devices as well as assembly recommendations. Local control wires can be extended up to 10m (insulate from 230 V).

Association

DELTA-DORE-TYXIA-4801-Wireless-Micro-Module-Receiver-
fig-9

  1. Switch the installation on. Press the receiver key for 3 seconds until the LED blinks. Release the key.
  2. Send the association command to the transmitter (refer to the user guide).
  3. Check that the receiver LED is no longer blinking. The product association is now complete.

Remove an association

DELTA-DORE-TYXIA-4801-Wireless-Micro-Module-
Receiver-fig-10

  1. Press and hold for 10 seconds:
    • after 3 seconds, the LED flashes slowly.
    • after 7 seconds, the LED flashes quickly. Release.
  2. Confirm on the transmitter (refer to the user guide).
  3. Make sure that the receiver LED has stopped flashing. The products are no longer associated.

Remove all associationsDELTA-DORE-TYXIA-4801-Wireless-Micro-Module-
Receiver-fig-11

  1. Hold down the receiver button for 20 seconds:
    • after 3 seconds, the LED flashes slowly.
    • after 7 seconds, the LED flashes quickly.
  2. Press and hold the button until the LED goes out. Release.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals