DELTA DORE TYXIA 4801 Wireless Micro Module Receiver Installation Guide
- June 16, 2024
- DELTA DORE
Table of Contents
DELTA DORE TYXIA 4801 Wireless Micro Module Receiver
Product Information
Specifications
- Model: TYXIA 4801 / 4811
- Website: www.deltadore.com
- TYXIA 4811: 230 V~, 50 Hz – 2 VA
- TYXIA 4801: Class II
- Maximum radio power: < 10 mW
- Receiver category: 2
- IP: IP40
- Dimensions: 50 x 47 x 33mm
- Power supply: 230 V~, 50/60 Hz
- LED: LED
Product Usage Instructions
Operation / Operation / Funktionsweise / Funzionamento / Funcionamiento / Dzialanie / Werking
Local wired control / Local hard-wired control / Lokaler Schaltereingang / Comando filare locale / Mando filar local / Lokalne sterowanie kablowe / Lokale bedrade bediening
FAQs
- What is the maximum power of TYXIA 4811?
- What is the IP rating of the product?
- Can the local control wires be extended?
Specification And Features
8 light bulbs max.
- 230 V halogen or 230 V incandescent bulbs
- 230V energy-saving compact fluorescent bulbs
- LED-Lampe 230 V
- Very low voltage 12V halogen or LED bulbs with AC or DC electronic transformer
- Very low voltage 12V halogen bulbs with ferromagnetic or toroidal transformer
Location
Behind the existing switch
Operation
ON / OFF
- Timed operation
- Manual override
- Warning that lighting is about to go off
- Timed operation initiated when ON is actuated.
- Timed operation initiated at end of detection.
- Phase Presence -> ON. The timed operation runs when the live is no longer present.
- Lights go out for 30’’, then 20’’ before they go out completely.
- Detection will be active only if it lasts more than 80 sec.
Connection
- A Any unconnected wire must be insulated (connecting block).
- B IMPORTANT, the control wires are not mains-isolated. Any equipment recorded must be marked CE and comply with the requirements of low-voltage devices as well as assembly recommendations. Local control wires can be extended up to 10m (insulate from 230 V).
Association
- Switch the installation on. Press the receiver key for 3 seconds until the LED blinks. Release the key.
- Send the association command to the transmitter (refer to the user guide).
- Check that the receiver LED is no longer blinking. The product association is now complete.
Remove an association
- Press and hold for 10 seconds:
- after 3 seconds, the LED flashes slowly.
- after 7 seconds, the LED flashes quickly. Release.
- Confirm on the transmitter (refer to the user guide).
- Make sure that the receiver LED has stopped flashing. The products are no longer associated.
Remove all associations
- Hold down the receiver button for 20 seconds:
- after 3 seconds, the LED flashes slowly.
- after 7 seconds, the LED flashes quickly.
- Press and hold the button until the LED goes out. Release.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>