DELTA DORE 6702001 Wireless Controller For Shutter And Heating Control Instruction Manual
- June 12, 2024
- DELTA DORE
Table of Contents
- Installation
- Mounting
- Operation
- Description
- Associate a thermal receiver with the Tywell Control
- Technical specifications
- Associate Tywell Pro with the Tywell Control using the Tydom application
- Confirm the link between the thermal receiver and the Tywell Control
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Tywell Control
Wireless controller for shutter and heating control
Installation
This product should be installed in a location with a temperature
representative of the room needing regulation. The recommended height is
around 1.5 m and the product should be away from heat sources (fi replaces,
sunlight, etc.) and draughts (windows, doors, etc.).
To avoid unwanted air movements that would distort the sensor’s temperature
measurements, the wire entry into the flush-mounted box must be plugged (with
mastic, glass wool, etc.).
IMPORTANT:
Do not install the controller on a wall in contact with the outside or in an
unheated room (e.g. garage, etc.).
Mounting
Operation
The Tywell Control operates devices, optimises energy use and makes a space
more comfortable.
– Centralised shutter control.
– Shutter autopilot.
For optimum autopilot results, a Tysense Sun sensor and a Tysense Thermo
outdoor temperature sensor are recommended.
Alternatively, the sensors can be replaced by weather service data from the
Tydom application as long as the Tywell Pro is connected to the internet.
– Automatic shutter management notifications
– Heating and air conditioning management (where there is a heating receiver)
– Absence mode
To manage your installation using the Tydom application, you need to associate
all Tywell Controls with the Tywell Pro bioclimatic manager.
Description
Associate a thermal receiver with the Tywell Control
If the Tywell Pro is already associated with the Tywell Control, associate
your receiver using the Tydom application.
In the Tydom application:
Add a device
Thermals
…
Select the receiver and follow the process.
Follow the instructions to link the thermal receiver controlled by the Tywell
Control.
In the Tydom application, select:
My devices
Select the relevant Tywell Control
Go to the Advanced options menu
Linked receiver
Follow the instructions to select, in the list of installed receivers, the one to be operated by the Tywell Control.
The selected receiver will flash.
(A receiver already associated with a Tywell Control and with a confirmed link will be greyed out and non-selectable.)
Technical specifications
– Power supply: 3 x 1.5 V – AAA LR03
– X3D wireless remote control device: 868.7 MHz to 869.2 MHz.
– Maximum wireless power < 10 mW
– Category 2 receiver
**** Dimensions: H 92 mm x L 92 mm x D 19 mm
– IP 30
– Storage temperature: -20°C to +70°C
– Operating temperature: -10°C to +40°C
Associate Tywell Pro with the Tywell Control using the Tydom application
When a receiver is already associated with the Tywell Control, the display shows:
To associate Tywell Pro with the Tywell Control:
– Press the configuration button, then select:
– The Settings menu, press the button to confirm
– The Status menu, press the button to confirm , release, then press the
button again for 5 seconds.
– The Associate menu, press the button to confirm
– Select Associate a Tywell Pro, press the button to confirm and follow
the process.
Confirm the link between the thermal receiver and the Tywell Control
This step is needed if the Tywell Pro is associated with the Tywell Control (step 6)
Follow the instructions to confirm the link between the thermal receiver and the Tywell Control using the Tydom application.
In the Tydom application, select your installation, then select:
My devices
Select the relevant Tywell Control
Go to the Advanced options menu
Linked receiver
Select the receiver associated with the Tywell Control, then press Confirm.
(A receiver already associated with a Tywell Control and with a confirmed link will be greyed out and non-selectable.)
When the link between the receiver and the Tywell Control has been established, the display shows:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>