AViANCE HD36949 Fixture 6.25 Inch 1 Light Polished Brass Wall Sconce Light Instruction Manual

June 1, 2024
AVIANCE

AViANCE HD36949 Fixture 6.25 Inch 1 Light Polished Brass Wall Sconce

Light

Specifications

  • Model: HD36949
  • Power Source: Electric
  • Material: Metal, Glass
  • Wattage Limit: Refer to fixture specifications

Product Usage Instructions

Assembling the Fixture:

  1. Return the arms to a suitable position.
  2. Attach the pipe(A) to the top pipe thread of fixture body(B) by turning it clockwise until tight.
  3. Raise the glass shade(C) to the lamp holder, lock it securely with the check ring(D) until tight.
  4. Install light bulbs (not included) according to the fixture’s specifications. Do not exceed specified wattage.

If you do not need to assemble the fixture loop, follow these steps:

  1. Take out the bottom loop of the canopy and attach it to the lamp body.
  2. Lock it with the lock washer and hex nut until tight.
  3. Attach the lamp body to the ceiling and lock it securely with ball nuts.

Hanging the Fixture:

  1. Shut off power at the circuit breaker and remove the old fixture from the ceiling.
  2. Lay out all parts on a clear surface.
  3. Thread mounting screws into pre-drilled holes in the Mounting plate and attach it to the Junction Box.
  4. Determine the correct number of links needed for hanging height and attach them securely.
  5. Lace the fixture wires through the chain and hang the fixture body from the ceiling.
  6. Connect fixture wires to ceiling junction box wires following proper color coding and twisting technique.

Connecting the Wires:

  1. Twist black wire from ceiling junction box with smooth wire leg from fixture and twist wire connector onto end of wire.
  2. Repeat with white junction box wire and ribbed wire leg of fixture wire, ensuring proper twisting direction.
  3. If there is a grounding wire in the junction box, attach it to the bare copper wire from the fixture. Otherwise, attach the bare copper fixture wire to the green ground screw on the mounting plate.

Tuck wire connections neatly into the ceiling outlet box and secure the canopy with ball nuts. Your installation is now complete. Restore power to test the fixture.

Frequently Asked Questions (FAQ):

Q: Can I use light bulbs with wattage higher than specified?
A: No, it is important not to exceed the specified wattage limit for safety reasons. Using higher wattage bulbs can damage the fixture or pose a fire hazard.

Q: How do I determine the correct hanging height for the fixture?
A: Measure and adjust the number of links in the chain to achieve the desired hanging height. Use proper chain pliers to disconnect excess chain length while ensuring secure attachment.

ASSEMBLING & INSTALLATION INSTRUCTIONS
The drawing shown may not exactly match the product enclosed.
However, the installation instructions do apply to this product.
HD36949

ASSEMBLING & INSTALLATION INSTRUCTIONS

WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.

ASSEMBLING THE FIXTURE (Fig.2)

AViANCE-HD36949-Fixture 6.25-Inch-1-Light-Polished-Brass-Wall-Sconce-
Light-1

  1. Return the arms to suitable position.
  2. Attach the pipe(A) to the top pipe thread of fixture body(B), by turning it clockwise until tight.
  3. Raise the glass shade(C) to the lamp holder, lock it securely with the check ring(D) until tight.
  4. Install the light bulbs(not included) in accordance with the fixture’s specifications.

NOTE: DO NOT EXCEED THE SPECIFIED WATTAGE!
If you not need assembly the fixture loop,Please pause and refer to Fig. 2.1.

  1. Take out the bottom loop of the canopy and take the loop of lamp body , then take the canopy to the lamp body, lock it with the lock washer and hex nut until tight.
  2. Attach the lamp body to the ceiling, lock it securely with the ball nuts.

HANGING THE FIXTURE (Fig.1)

  1. Shut off the power at the circuit breaker and remove old fixture from ceiling, including the old single bar. Carefully unpack new fixture and lay all the parts on a clear surface.

  2. Thread the two mounting screws into the pre-drilled holes in the Mounting plate spaced the same distance apart as the holes in the canopy. Attach the Mounting plate to the Junction Box with the two Junction Box Screws as shown. The side of the Mounting plate marked “GND” must face to out. The junction box is not included.

  3. By measuring, determine correct number of links needed for proper hanging height.
    Using proper chain pliers disconnect and discard remaining chain. Attach the end pipe thread of the chain into the canopy center hole, lock it securely with the lock washer and hex nut.

  4. Lace the fixture wires through the chain.

  5. Open the end link of the chain and hang the loop at the ceiling and fixture body. Close the link.

  6. Feed the fixture wires through the loop of the canopy and pull until taut.

  7. Slide canopy up flush to ceiling, lock it securely with ball nuts.

CONNECTING THE WIRES (Fig.3)

AViANCE-HD36949-Fixture 6.25-Inch-1-Light-Polished-Brass-Wall-Sconce-
Light-2

  1. Take the black wire from the ceiling junction box and the smooth wire leg from the fixture and twist bare ends together. Twist wire connector onto end of wire until snug.

  2. Repeat same process with white junction box wire and ribbed wire leg of fixture wire.
    NOTE: Twist wires together in the same direction you twist the wire connector onto wires.

  3. If your junction box has a grounding wire (green or bare copper), attach this wire and the bare copper wire from the fixture together as step 1.If junction box has no ground wire, attach the bare copper fixture wire to the green ground screw on the mounting plate.

  4. Tuck these wire connections neatly into the ceiling outlet box and then raise the canopy all the way to the ceiling, lock it securely with ball nuts.

Thank you for purchasing an AVIANCE product.