Specifications

  • Product Name: 961243-C-GFCI and 961243-S-GFCI One Gang Pop-up Floor Box Assembly with 20A GFCI Tamper Resistant Duplex Receptacle
  • Description/Features: One gang pop-up floor box with 20 amp GFCI tamper-resistant duplex receptacle

Product Usage Instructions

Installation

  • WARNING: Turn the POWER OFF at the circuit breaker before installing the Floor Box.
  • Read and understand these instructions before installing. This device is intended for installation by the National Electric Code and local regulations.
  • It is recommended that a qualified electrician perform this installation.
  • Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device. Use copper wire only, or equivalent.

Floor Box Installation

Before Installation: Ensure there is sufficient
depth & space below the subfloor.

  1. Step 1: For carpeted floors, cut out a section of carpet smaller than the size of the cover.
  2. Step 2: Rout 3/8(9mm) Deep For Outer Tabs.

Wiring Directions

  1. Insert the HOT wire into the LINE terminal and tighten the screw.
  2. Insert the NEUTRAL wire into the NEUTRAL terminal and tighten the screw.
  3. Insert the GROUND wire into the GREEN terminal and tighten the screw.
  • Hot (Black wire)
  • Neutral (White wire)
  • Ground (Green or bare wire)

Warranty Information

  • For warranty information, please refer to the product documentation provided with your purchase.

FAQ

Q: Can I install this product without professional help?

  • A: It is recommended that a qualified electrician be installed to ensure safety and proper functionality.

Q: What type of wire should be used for installation?

  • A: Use 10-12 AWG Stranded or Solid Copper wire as recommended for installation.

SPECIFICATIONS

Cover Material

  • 961243……………………………………………………………………………Brass(C) or Nickel-Plated Brass(S)
  • Receptacle Rating…………………………………………………………………………………………..20A 125VAC
  • Box Material……………………………………………………………………………………………..Galvanized Steel
  • Knockout size…………………………………………………………………………………………………1/2″ and 3/4″
  • Adjustable Height………………………………………………………………………………………….up to 1″ depth

DESCRIPTION/ FEATURES

  • Included is a One Gang pop-up floor box with a 20 amp GFCI tamper-resistant duplex receptacle
  • Compact and stylish design with adjustable height function metal box with the choice of Brass(C) or Nickel-Plated Brass(S).
  • Corrosion-resistant hardware ensures a long life span and reliable performance.
  • Easy access to power when you need it. Snap the cover closed when not in use.
  • Used for carpet and wood floors. Also great for countertop applications.

WARNING

  • Turn the POWER OFF at the circuit breaker before installing the Floor Box
  • Read and understand these instructions before installing. This device is intended for installation under the National Electric Code and local regulations. It is recommended that a qualified electrician perform this installation.
  • Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device. Use copper wire only, or equivalent.
  • NOTES: 10-12 AWG Stranded or Solid Copper wire is recommended

FLOOR BOX INSTALLATION

Before Installation:

  • Ensure there is sufficient depth & space below the subfloor.

Step 1

For carpeted floors:

  • Cut out a section of carpet smaller than the size of the cover.

For wood sub-floors and finished hardwood floors:

  • Tape the template on the area you want to place the floor box.
  • Use a knife to cut the outline of the box. Start with the ears and move inwards.
  • Following the outline, cut the box shape without the ears completely through the subfloor or hardwood floor.
  • Following the outline, cut 3/8″ deep into the subfloor or hardwood for the mounting ears.
  • Using a router is recommended

Step 2

  • Remove knockouts and secure the box onto the floor. Pull the wires through the opening of the floor and the knockout and connect the wires based on the wiring diagram.
  • Use the proper connector/ clamp at the knockouts to secure the wires and avoid accidental wire stripping.
  • Secure the box to the opening using wood screws.

WIRING DIRECTIONS

  1. Insert the HOT wire into the LINE terminals and tighten the screw.
  2. Insert the NEUTRAL wire into the NEUTRAL terminal and tighten the screw.
  3. Insert the GROUND wire into the GREEN terminal and tighten the screw.ENERLITES-961243-C-GFCI-Nickel-PlatedSquareFloor-Box-with-TR-GFCI-Outlet-FIG-2

WARRANTY INFORMATION

  • This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase. An original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim.
  • ALL claims must be verified and approved by Enerlites, Inc. Warranties from other Enerlites products may vary.
  • This warranty is non-transferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation.
  • To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end-user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement, or refund.
  • Repair, replacement, or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
  • © 2019 Enerlites Inc. CA, U.S.A.
  • WWW.ENERLITES.COM
  • 0202190135-02
  • REV 20230802

Documents / Resources

| ENERLITES 961243-C-GFCI Nickel Plated Square Floor Box with TR GFCI Outlet [pdf] Instructions
961243-C-GFCI Nickel Plated Square Floor Box with TR GFCI Outlet, 961243-C-GFCI, Nickel Plated Square Floor Box with TR GFCI Outlet, Square Floor Box with TR GFCI Outlet, Floor Box with TR GFCI Outlet, TR GFCI Outlet
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ENERLITES User Manuals

Related Manuals