Nexans 8TP 2SFP+ AC LANactive XGigaSwitch Dice
Product Information
The product described in this user manual is the Nexans XGigaSwitch series. The manual provides information about the features, functions, operation, and commissioning of the following devices:
- XGigaSwitch DICE 8TP 2SFP+ AC
- XGigaSwitch DICE 8TP 2SFP+ DC
- iOption PoE++ 6/8P-90W
- iOption PoE+ 6/8P-30W
The manual is intended for planners and installers of enterprise network solutions, electrical engineers, and individuals responsible for setting, testing, and maintaining office switches. It applies to the Nexans XGigaSwitch series in combination with the current version of the Nexans Device Manager, LANactive Manager Version 7.02.
For more detailed information on specific features and specifications, please refer to the product’s web page and datasheet.
Product Usage Instructions
Safety Instructions
- Only qualified personnel should install and commission the XGigaSwitch.
- Comply with country-specific regulations.
- For device protection, connect a thermomagnetic fuse.
- Never work with applied voltage to avoid electric shock.
- Maintenance and repairs should only be carried out by the manufacturer or authorized personnel.
- Clean the switch using a cloth dampened with a mild cleaning agent. Take care not to let any cleaning agent enter the interior of the unit.
- Dispose of the switch and all electronic parts properly according to legal requirements at a responsible collection point.
- Use only original accessories. Other accessories are allowed as long as they do not compromise the safety of the device.
If you have any questions or encounter problems, please contact Nexans support via the following email address: support.ans@nexans.com.
To access the latest firmware, management tool, release notes, and software manual, visit the Nexans Support Portal at https://www.nexans- ans.de/support/.
For personalized and extended product support, Nexans recommends contacting them via email at sales.ans@nexans.com to inquire about a Nexans support contract.
Please note that the manual’s content has been checked for compliance but deviations may occur. The information is regularly reviewed and updated in subsequent editions. Suggestions for improvement are welcomed, and technical changes may be made without notice.
General Information
Nexans Advanced Networking Solutions GmbH (ANS) as part of Nexans Telecom & Data Business Group is a market pioneer for Fibre To The Office (FTTO) systems. Nexans offers over 35 years of experience in research, development and production of FTTO and Industrial Ethernet switches. Customers include top global companies and institutions. Nexans guarantees exceptional product quality ‘Made in Germany’. With an integrated concept including accessories and software features, Nexans offers end users and partners an extensive support program, tailor-made concepts and the ability of customization.
Purpose of the manual
This manual describes the features, functions, operation and commissioning of
the following devices of the XGigaSwitch series:
- 88306800 XGigaSwitch DICE 8TP 2SFP+ AC
- 88306801 XGigaSwitch DICE 8TP 2SFP+ DC
- 88301666 iOption PoE++ 6/8P-90W
- 88301604 iOption PoE+ 6/8P-30W
Target group
This document is designed for planners and installers of enterprise network
solutions, electrical engineers, persons entrusted with setting, testing and
maintaining office switches.
Scope of the manual
This manual is valid for the Nexans XGigaSwitch series in combination with the
current version of the Nexans Device Manager, LANactive Manager Version 7.02.
The User Manual may include more than one product. Part of the content, e.g. some use cases or specifications, may only apply to some of them. For more information on the exact feature set and specifications, see the product’s web page and datasheet.
Support
The latest version of the firmware and the management tool can be downloaded
at the Nexans Support Portal: https://www.nexans-ans.de/support/. There are
also all related release notes and the current versions of software manual
available.
For any questions or problems, please contact the following support e-mail
address: support.ans@nexans.com
To benefit from individualized and extended product support, Nexans recommend
concluding a Nexans support contract. To get more information, please contact
Nexans via e-mail: sales.ans@nexans.com
Disclaimer
The content of this manual has been checked for compliance with the hardware
and software described. Nevertheless, deviations cannot be ruled out, so no
liability is assumed for the complete agreement. The information in this
manual is reviewed regularly and any necessary corrections are included in
subsequent editions. Suggestions for improvement are welcomed. Technical
changes are reserved, even without notice.
Safety Instructions
Safety instructions
Only qualified personnel may install and commission the XGigaSwitch. Country-
specific regulations must be observed.
- It is only allowed to install the device in a dry and dust-free environment.
- Avoid direct solar irradiation to the device and ensure sufficient ventilation.
- Liquids must not enter the device.
- Do not open the device. There is the risk or electric shock.
ATTENTION: Electrical damage
For device protection, connect a thermomagnetic fuse.
CAUTION: Danger due to electric shock!
Never work with applied voltage.
Maintenance and Repair
The switches are maintenance-free devices. Repairs are only permitted by the
manufacturer or by persons authorized by the manufacturer. In case of doubt,
please contact the manufacturer.
Cleaning
The switch can be cleaned using a cloth that has been dampened with a mild
cleaning agent. Please take care that no cleaning agent enters the interior of
the unit.
Waste Management
After use, the switch and all electronic parts contained in the scope of
delivery must be disposed of properly according to legal law at a responsible
collection point.
Accessories
Only original accessories may be used. Any other accessories are only allowed
if they do not impair the safety of the device
Packaging
Do not throw away the packaging. The packaging has been designed for repeated
use if not damaged during transport. Only the original packaging can reliably
protect the unit from damage during later transport.
Checking the scope of delivery
After receiving the product, the scope of delivery should be checked. A
detailed list of the scope of delivery is shown in the chapter Technical Data
on page 8.
Checking for transport damage
Please check the unit for transport damage after unpacking. Transport damage
can be assumed in particular if the packaging is visibly damaged. Do not try
to operate an obviously damaged unit. This may result in further consequential
damages.
Recovery after storage and transport
Moisture can condensate on the unit if the unit has been stored or transported
at low temperatures and subsequently taken into a warm room. To avoid any
damage please wait till any moisture condensation has vanished from the unit’s
surface before switching the unit on. The unit is operational only after it
has reached the guaranteed operating temperature range (see Technical Data on
page 8). The same applies also to prior storage at high temperatures.
Product Labels
The Nexans LANactive XGigaSwitch DICE is equipped with product labels for the
purposes of quality assurance and documentation. The product labels contain
unique device-specific information that can be used for project documentation.
This information includes MAC address and serial number. The two numbers are
unique and refer to each individual device.
The information about the respective MAC address is located twice on the
switch. Once on the bottom side of the device and a second at the front. The
sticker at the front can also be read when the XGigaSwitch is installed.
Use the barcodes of the product label with the MAC address and serial number
information to simply read in the device lists using commercially available
scanners and document them in tabular form. Associate the MAC address with the
information about the installation location and the switch description
.
Product Features
LANactive 10G/MultiGigabit Ethernet Managed Switch
- 2 Uplink Ports (SFP+) and 8 Access Ports (RJ45)
- Power over Ethernet (PoE++) up to 90Watts per port (optionally)
- Energy Efficient Ethernet
- Memory Card Slot
- Wide Input Voltage Range: 46 … 57V DC or 90 … 264V AC
Description
Nexans LANactive XGigaSwitch is optimized for supporting Wireless LAN
infrastructures. Based on MultiGigabit copper and 10 Gigabit SFP+ interfaces
the switch is able to support the bandwidth required by the latest Wireless
LAN standards.
Access Ports
The XGigaSwitch has 8 Access Ports connecting Wireless LAN Access Points, IP
Cameras, Connected Lighting or Smart Building Systems. Four Access Ports
supporting MultiGigabit to avoid any bottleneck with the latest WLAN
technology standards.
Ceiling Installation
A very compact design allows a smart ceiling installation. In combination with
the fanless design the operation without noise is guaranteed. A separate power
supply allows flexible support of all power budgets.
Power over Ethernet
The latest Power over Ethernet standard IEEE802.3bt enables remote powering
with up to 90W per port. Equipment like Wireless LAN Access Points, IP-
Cameras, Connected Lighting or Smart Building Systems can be supplied with
power from the switch directly. The Power over Ethernet functionality can be
parameterized, controlled and monitored via management.
Memory Card
The optional memory card automatically saves the complete current
configuration and firmware of the device. In case of failure, this feature
allows an easy exchange of the hardware without additional configuration. In
addition, each memory card can be delivered with its own MAC address that is
adopted by the switch.
Switch Management and Zero-Touch Configuration
LANactive Manager allows a simple and secure configuration of all device
parameters of the XGigaSwich series. With LANactive Manager a larger number of
XGigaSwitches can be managed and monitored at the same time. In combination
with Nexans Zero-Touch Configuration, the LANactive Manager allows the
automatic distribution of configurations and firmware updates. A pre-
configuration of the switches is not necessary.
Technical Data
The following table contains the basic technical data and the differences in
the available versions. A detailed technical overview can be found in the
corresponding datasheet of the products.
| XGigaSwitch DICE 8TP 2SFP+ AC| XGigaSwitch DICE 8TP 2SFP+ DC
---|---|---
Article Number| 88306800| 88306801
Uplink Ports| 2x SFP+ with 1/10 Gbps
User Ports| 4x 2.5GBase-T and 4x 1000Base-T
PoE Options| 8x PoE+ or 8x PoE++ via option, see table below
Memory Card Slot| Yes, SD-Card
Dimensions (B x H x D)| 345 x 53 x 170 mm
Weight| 1,900g| 1,500g
Operating Temperature| 0…45°C
Input Voltage Range| 90…264V AC| 46…57V DC
Power Connector| C14 connector (L, N, PE)| 3-pin connector with plug-in screw
terminal (up to 2.5mm²) / (+) (-) (FG)
Scope of Delivery| Power cable, 1,5m with Power Connector (CEE 7/4)
4x stick-on pads Documentation
| 3-Pin Power Connector
4x stick-on pads Documentation
iOption* | iOption PoE+ 6/8P-30W | iOption PoE++ 6/8P-90W |
---|---|---|
Article Number | 88301604 | 88301666 |
According to | IEEE802.3at, PoE+ | IEEE802.3bt, PoE++ |
Number of PoE Ports | 8x PSE(PoE+) acc. to IEEE802.3at | 8x PSE(PoE++) acc. to |
IEEE802.3bt, Type 3&4
PoE Mode| 30W per Port, Mode A, Pin 1-2/3-6| Up to 90W per Port, 4-Pair 1-2/3-
6/4-5/7-8
options are optionally and must be ordered separately. If an iOption has been ordered, it is mounted and integrated during the production process. An integration later in the field is not possible.
Dimensions
Interfaces
XGigaSwitch DICE 8TP 2SFP+ AC
- 230V AC Power Connector (Type: C14) 90…264V AC ~50/60Hz, 6.5A(115V), 3.0A (230V)
- RJ45 Port 1-4: 1000Base-T (1000/100/10 Mbps)
- RJ45 Port 5-8: 2.5GBase-T (2500/1000/100 Mbps)
- Port 9-10: SFP+ (1/10 Gbps)
- Console port (RJ45)
- MAC-Address label
- Status LEDs (Mgmt. on front and top)
- I/O Interface
- DIP switches
- SET Button
- Memory Card slot (Format: SD)
XGigaSwitch DICE 8TP 2SFP+ DC
- 54V DC Power Connector , see chapter: Power Connection on page 17
- RJ45 Port 1-4: 1000Base-T (1000/100/10 Mbps)
- RJ45 Port 5-8: 2.5GBase-T (2500/1000/100 Mbps)
- Port 9-10: SFP+ (1/10 Gbps)
- Console port (RJ45)
- MAC-Address label
- Status LEDs (Mgmt. on front and top)
- I/O Interface
- DIP switches
- SET Button
- Memory Card slot (Format: SD)
- Grounding Screw
LED Indicators
The following table shows the LED status.
LED Indicators
Mounting Options
MOUNTING OPTIONS
The XGigaSwitch DICE can be physically installed in various ways. It can be
used as a desktop device or in combination with different types of mounting
kits.
Desktop Usage
The easiest way to use the XGigaSwitch DICE is the usage as a desktop device.
The scope of delivery contains four pads to stick-on the bottom side of the
switch.
On-wall Installation with Hook-On Mechanism
For an on-wall installation different mounting kits are available. With the
basic mounting plate (part number 88646400) the XGigaSwitch DICE can be
mounted on the wall toolless.
An additional strain-relief (part number: 88646401) can be fix to the mounting plate.
The strain-relief is fixed to the mounting plate with the attached screws .
The XGigaSwitch DICE is mounted via a so-called hook-on mechanism to the mounting plate. Detailed information regarding the installation are written in a separate document.
19” Installation
To install the LAN active XGigaSwitch DICE in a 19” rack the following
adaptors are available (part number: 88646402).
The adaptors are mounted with the attached screws on the bottom side of the
XGigaSwitch DICE.
DIN-Rail Installation
For a DIN-Rail installation, a separate DIN-Rail mounting clip (part number:
88306811) can be used. The mounting clip can be fix at the bottom side of the
switch. For the mounting only the attached screws must be used.
Power Connection
The XGigaSwitch DICE AC version has an integrated power supply and may be
connected to a 110/230V AC circuit. Therefore, the enclosed power cord should
be used.
Pin Assignment for 54V DC connection
The XGigaSwitch DICE DC version has no integrated power supply and must be
connected to a 54V DC power source. It is recommended to use the power supply
unit offered by Nexans (see chapter External Power Supply on page 18Fehler!
Textmarke nicht definiert.).
In case another power source is used e.g. a central power supply, the enclosed
3-pin connector may be used to connect the XGigaSwitch to the DC power source.
The following table shows the pin assignment and technical parameter to
connect the 3-pin connector.
In any case please check the correct pin assignment and the correct polarity of the wiring at the supply unit.
External Power Supply
Ordering Information | Desktop Power Supply 54VDC/240W |
---|---|
Article Number | 88646283 |
Output Power | 240W |
Connector Primary | C14 |
Connector Secondary | 3-pin plug-in terminal |
Dimension (L x W x H) | 187 x 87 x 39 mm |
Power over Ethernet
Power over Ethernet is an attractive and standardized alternative for the power supply of LAN equipment such as VoIP phones, Wireless LAN Access Points, IP video cameras etc., while using the “normal” Ethernet standard cable, i.e. without any additional cable tangle.
Function
An power source equipment (PSE) ensures the power supply of a powered device
(PD). Nexans LANactive XGigaSwitch DICE series supports all three different
PoE standards.
-
PoE IEEE802.3af
-
PoE+ IEEE802.3at
-
PoE++ IEEE802.3bt
For Poe and PoE+, the standard defines 3 modes of operation for power supply, which is ensured via different wire pairings of the TP data connection: -
Endpoint PSE mode A – power supply via TP pairs 1/2 and 3/6
-
Endpoint PSE mode B – power supply via TP pairs 4/5 and 7/8
-
Midspan PSE mode B – power supply through an external device via TP pairs 4/5 and 7/8
PoE++ is using all four pairs (1/2, 3/6, 4/5, 7/8) for power transmission. However, PoE++ is backward compatible, which means PoE or PoE+ PDs can be connected and powered.
The PoE solution will only supply power if an appropriate powered device (PD) is detected. The following functions are checked prior to enabling PoE power supply: -
The active PSE source identifies the powered device (PD).
-
The operational mode is detected.
-
The required power class is detected based on the classification current.
Thus, any damages can be avoided, if the connected terminal unit is not standard-compliant.
In any case please check the correct pin assignment and the correct polarity of the PoE wiring at the terminal unit.
Mode A—Pairs 1/2 and 3/6
Power Source Equipment (PSE) | Powered Device (PD) |
---|---|
MDI(X) | |
1 BI_DB+ | PoE- |
2 BI_DB- | PoE- |
3 BI_DA+ | PoE+ |
4 BI_DD+ | |
5 BI_DD- | |
6 BI_DA- | PoE+ |
7 BI_DC+ | |
8 BI_DC- |
Power over Ethernet
Power Source Equipment (PSE+)
Thanks to the optional Power over Ethernet functionality, PoE-capable end
devices can be supplied with power in accordance with corresponding IEEE 802.3
standard directly from the switch. The Power over Ethernet functions can be
parameterized, controlled and monitored via management.
PoE class| Max. output power at PSE| Available power at PD|
Classification signature| PoE standard
---|---|---|---|---
0| 15.4 W| 0.44 – 12.96 W| 0 – 4 mA| IEEE 802.3af/at
1| 4 W| 0,44 – 3.84 W| 9 – 12 mA| IEEE 802.3af/at
2| 7 W| 3.84 – 6.49 W| 17 – 20 mA| IEEE 802.3af/at
3| 15.4 W| 6.49 – 12.95 W| 26 – 30 mA| IEEE 802.3af/at
4| 30 W| 12.95 – 25.50 W| 35 – 45 mA| IEEE 802.3at
5| 45W| 25.5 – 40W| 36 – 44mA/1 – 4mA| IEEE 802.3bt
6| 60W| 40 – 51W| 36 – 44mA/9 – 12mA| IEEE 802.3bt
7| 75W| 51 – 62W| 36 – 44mA/17 – 20mA| IEEE 802.3bt
8| 90W| 62 – 71.3W| 36 – 44mA/26 – 30mA| IEEE 802.3bt
Permitted voltage levels
The voltage ranges for the supply of switches are defined as follows:
PoE standard
|
Max. output power per port
| Specified voltage range at the Power Source Equipment (PSE)| Voltage
level at the switch, min. / typ. / max.
---|---|---|---
IEEE 802.3af (Type 1)| 15.4W| 44 – 57V DC| 46 / 48 / 57V DC
IEEE 802.3at (Type 2)| 30W| 50 – 57V DC| 50 / 54 / 57V DC
IEEE 802.3bt (Type 3)| 60W| 50 – 57V DC| 50 / 54 / 57V DC
IEEE 802.3bt (Type 4)| 90W| 52 – 57V DC| 50 / 54 / 57V DC
Please check compatibility, proper pin assignment and polarity prior to and
during putting the system into operation to avoid any damage resulting from
attaching incompatible equipment.
The maximum load of the individual ports and the overall load are limited.
These limits have to be observed in any case. Otherwise the connected units
might be damaged or cannot be operated (see Technical Data).
Grounding
XGigaSwitch for DC connection
To prevent unwanted interference and failures, the correct grounding of the
XGigaSwitch DICE is very important. This becomes much more important if Power
over Ethernet (PoE) is used and multiple powered (PD) devices are connected to
the switch. Nexans confirms that all LANactive switches are developed and
manufactured according to the requirements of the PoE standards as defined by
the Institute of Electrical and Electronics Engineers (IEEE) IEEE802.3af,
IEEE802.3at and IEEE802.3bt. In case of a centralized power supply that powers
multiple switches and thus multiple PoE devices, the grounding must be
connected next to the central power supply. In this case the plus voltage must
be grounded by connecting it to the potential equalization of the building.
The following figure shows the schematic of grounding the plus voltage
.
The switch can be grounded locally with the grounding terminal of the housing or connected to the central grounding by using a three-wired cable (+, -, Ground).
Never use the minus pol for grounding! In case of a wrong grounding at the connected client, the risk of a short circuit is given.
Memory Cards and Console Cables
Memory cards for switches
Nexans memory cards are redundant encrypted storage (AES256) for all types of
LANactive switches which always stores its complete and most actual
configuration and firmware automatically.
To make network maintenance processes easier, Nexans memory cards have unique
MAC address fixed on it. Switch replaces its own MAC address with the one read
from a memory card. In case of a switch replacement, the SD card needs to be
removed from one switch and installed into the new one. The MAC address,
configuration, and firmware will be taken on by the new switch from this SD-
card. So, no changes in the network policy or pre-setup works need to be made
as the system will see same switch as before.
Ordering Information| SD Memory Card with MAC-Address| SD Memory
Card with MAC-Address plugged
---|---|---
Article Number| 88300692| 88300696
Delivery| Separately in plastic case| Pre-installed in the switch
Console configuration cables
The V.24 console port on Nexans switches allows you to configure the switch on
site and/or retrieve its status without an Ethernet network connection.
Configuration via the V.24 console port provides the same functionality as
configuration via Telnet or SSH.
Ordering Information | RJ45 to USB adapter for serial console |
---|---|
Article Number | 88300716 |
Connector A | RJ45 |
Connector B | USB |
I/O Module
The Nexans XGigaSwitch supports I/O ports on the front side of the device. The output, digital inputs and 24V DC output are electrically isolated against each other. The status and fault diagnostics of the I/O ports are monitored in the switch management.
The I/O module has one relays with two contact outputs, which by default have two functions – open and closed. This allows switching of the two digital channels. The relay output can switch two relay contacts. One contact is normally open and one normally closed. The relay contact outputs are controlled via user-configurable setpoints through switch management. The setpoints, operating parameters and interaction can be set in the “Industrial Alarms” menu of the switch management.
Pin | Signal |
---|---|
1 | Relay contact normally closed contact |
2 | Relay common pin |
3 | Relay contact normally opened contact |
The digital inputs are designed to receive 12-60VDC signals polarity with a max. input current of 1.5mA per input. The states of the input contacts is shown in the management.
Pin | Signal |
---|---|
4 | Digital input contact 1 |
5 | Digital input contact 2 |
6 | Auxiliary voltage output power +24VDC, max. 40mA |
7 | Auxiliary voltage output power – (GND) |
The output can be used as an auxiliary voltage to power the digital input without the need of an external power source.
Start-up – Booting
Nexans LANactive XGigaSwitch DICE can be operated in different modes called
‘Operation Mode’. The following chapter explain the differences and how to
switch between the different modes. If nothing is changed the switch boots
with the default configuration stored in flash and DHCP for dynamic IP address
assignment.
Operation Mode
The ‘Set Button’ (see Figure 4 no. 10) is used for selecting the following
operating modes:
- Booting with flash configuration (default mode)
- Booting with fixed IP address
- Booting with factory default settings
- Booting with factory default settings and fixed IP address (optional)
IMPORTANT NOTE: The boot functions ‘Booting with fixed IP Address’ and
‘Booting with Factory Default Settings’ can be individually disabled via the
management feature to prevent an accidental or deliberate manipulation by the
user.
After disabling the switch “Boot with factory default settings”, a reset of
the switch to factory default settings is only possible via management access.
- Hold the configuration button >3 sec.
By pressing and holding the pushbutton (min. 3 seconds) the switch will change into the configuration mode, which is indicated by the Mgmt-LED going out. As soon as the Mgmt-LED is permanently off, the pushbutton must be released. A rapidly flashing blue Mgmt-LED shows that function number 1 has been selected.
Briefly press configuration button
By briefly pressing the pushbutton (min. 0.1 second) the desired function can now be selected, which is indicated via the respective LED colour:
Colour | Status |
---|---|
Blue | Booting with flash configuration |
Red | Booting with fixed IP address (172.23.44.111) |
White | Booting with factory default settings |
Cyan | Booting with customer default settings |
Magenta | Booting without customer default settings |
Hold configuration button >3 sec.
To execute the selected function, the pushbutton must be pressed and held for
at least 3 seconds. The Status-LED flashes briefly and goes out to show that
the switch has accepted the command. Now the pushbutton can be released, and
the switch will boot to execute the command.
Note: The configuration mode is automatically exited, when the pushbutton
is not pressed for more than 30 seconds.
Note: The functions four and five are only displayed if the respective
configuration is stored.
Start-up – Booting
Booting with Flash Configuration
By default, the switch loads all configuration parameters stored in the flash
during the boot process.
In case the customer has ordered a default customized configuration, this is
configuration is written to the flash during the production process and is
available for the very first start-up.
Nexans default configuration comes with DHCP for addressing the switch. The
switch sends a DHCP request as soon as the Status-LED lights up permanently on
the management module. If it receives a valid response from a DHCP server, the
IP parameters are accepted, and the management module can be immediately
accessed via the assigned IP address. If the switch does not get a response,
the DHCP request is repeated at increasing time intervals (with a maximum
interval of approx. 30 seconds).
In case Nexans LANactive Manager with Zero-Touch Configuration is available in
the network environment after DHCP the switch will connect automatically to
the Controller and can be configured via LANactive Manager User Interface.
If the switch has booted with a plugged-in MC card having a valid switch
configuration, the ‘MC’ LED will light up for some seconds during booting.
When the loading of the configuration of the MC card is completed, the ‘MC’
LED lights up permanently in green.
ANS Support Portal
Important notes for switches with Management Hardware HW5 Nexans strongly
recommends downloading and installing the latest Switch Firmware Version. This
ensures to have all the new features and bug fixes. In addition to the new
firmware, the current version of the Nexans LANactive Manager must be
installed to manage switches with Management Hardware HW5. This manager
version is also backward compatible with switches using Management Hardware
HW3, HW2 and HW1. The current version of LANactive Manager also includes the
configuration options for all new firmware features. If you are not yet a
registered user of the Nexans Support Portal, please register at the Nexans
support portal http://www.nexans-ans.de/support/ and download the latest
version of the firmware and the management tool. Here you will also find the
related release notes and the current versions of the management manual.
If you have any questions or problems, please contact us at the following
support e-mail address:
support.ans@nexans.com
To benefit from individualized and extended product support, we recommend
concluding a Nexans support contract.
If you are interested, please send us your request by e-mail to
sales.ans@nexans.com.
Please visit our support portal under:
At our support portal, you’ll find the latest information and downloads of the following points:
- Documentation
- Installation instructions
- Starter Kits
- Quick Start
- Release Notes
- Nexans LANactive Manager
- Firmware Images
- SNMP MIBs
- RMA Request
- Frequently Asked Questions (FAQs)
Nexans Advanced Networking Solutions GmbH
- Support Team
- Phone: +49 (0) 2166 27-2017
- E-Mail: sales.ans@nexans.com
- Sales Team / RMA Service
- Phone: +49 (0) 2166 27-2220
- E-Mail: sales.ans@nexans.com
EC Declaration of Conformity
The manufacturer
Nexans Advanced Networking Solutions GmbH Bonnenbroicher Strasse 2-14 41238
Moenchengladbach Germany
declares under its sole responsibility that the products:
- 88306800 XGigaSwitch DICE 8TP 2SFP+ AC
- 88306801 XGigaSwitch DICE 8TP 2SFP+ DC
- 88301666 iOption PoE++ 6/8P-90W
- 88301604 iOption PoE+ 6/8P-30W
following the provisions of directives
- 2014/30/EU Electromagnetic Compatibility Directive
- 2014/35/EU Low Voltage Directive
- 2011/65/EU RoHS 2
to which this declaration relates are in conformity with the following directives and standards:
- EN 62368-1:2014 Audio/video, information and communication technology equipment – Part 1: Safety requirements
- EN 55032:2012 Electromagnetic compatibility of multimedia equipment – Emission requirements
- EN 55024:2016 Information technology equipment – Immunity characteristics – Limits and methods of measurement
- EN 61000-3-2:2104 Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions
- EN 61000-3-3:2013 Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16A per phase and not subject to conditional connection
- EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances
Accessories
Power over Ethernet Options
Nexans art.-nr. | Description |
---|---|
88301604 | PoE/PoE+ option: iOption for 6/8x ports with 30W each |
88301666 | PoE/PoE+/PoE++ option: iOption for 6/8x ports with 90W each |
Memory Cards
Nexans Part No. | Description |
---|---|
88300692 | SD Memory Card with MAC |
88300696 | SD Memory Card with MAC integrated |
Nexans FTTO Power Supplies
Nexans Part No. | Description |
---|---|
88646283 | Desktop Power Supply 54VDC/240W |
88646077 | Power Supply for Desk Devices 54VDC/65W |
Nexans LANactive Manager
Nexans Part No. | Description |
---|---|
88301908 | LANactive Manager Single User Licence |
88301909 | LANactive Manager Company Licence |
88301920 | LANactive Manager Controller Licence |
Nexans device manager can be downloaded free of charge for evaluation |
purposes (max. five switches in device list and delayed starting screen) at www.nexans-ans.de/support/
Small Form Factor Pluggable Transceiver
Nexans Part No. | Description |
---|---|
88646390 | Nexans SFP+, 10G Base-SR, 850nm MM; 10 Gigabit Ethernet; Multimode; |
Tx/Rx: 850/850nm; 400m@OM4; LC-duplex; DDM Support; temp.r: -40°C/+85°C; dual
fibre
88646391| Nexans SFP+, 10G Base-LR, 1310nm SM; 10 Gigabit Ethernet;
Singlemode; Tx/Rx: 1310/1310nm; 10km; LC-duplex; DDM Support; temp.r:
-40°C/+85°C; dual fibre
88646392| Nexans SFP+, 10G Base-BX-U, 1270nm SM Bi; 10 Gigabit Ethernet;
Singlemode; Tx/Rx: 1270/1330nm; 10km; LC-simplex; DDM Support; temp.r:
-40°C/+85°C; single fibre
88646393| Nexans SFP+, 10G Base-BX-D, 1330nm SM Bi; 10 Gigabit Ethernet;
Singlemode; Tx/Rx: 1330/1270nm; 10km; LC-simplex; DDM Support; temp.r:
-40°C/+85°C; single fibre
88646015| Nexans SFP 1000 Transceiver GI(LC)E; Gigabit Ethernet; Multimode;
Tx/Rx: 850/850nm; 550 m; LC-duplex; DDM Support; temp.r: -40°C/+85°C; dual
fibre
88646016| Nexans SFP 1000 Transceiver SM(LC)E L10; Gigabit Ethernet;
Singlemode; Tx/Rx: 1310/1310nm; 10 km; LC-duplex; DDM Support; temp.r:
-40°C/+85°C; dual fibre
88646073| Nexans SFP 1000 Transceiver SF3(LC)E L10; Gigabit Ethernet;
Singlemode; Tx/Rx: 1310/1550nm; 10 km; LC-simplex; DDM Support; temp.r:
-40°C/+85°C; single fibre
88646075| Nexans SFP 1000 Transceiver SF5(LC)E L10; Gigabit Ethernet;
Singlemode; Tx/Rx: 1550/1310nm; 10 km; LC-simplex; DDM Support; temp.r:
-40°C/+85°C; single fibre
Mounting Kits
Nexans Part No. | Description |
---|---|
88646400 | XGigaSwitch DICE Mounting Plate |
88646401 | XGigaSwitch DICE Strain Relief |
88646402 | XGigaSwitch DICE 19″ Mounting Kit |
88306811 | XGigaSwitch DIN-Rail Mounting Kit |
Nexans Support-Packages
Nexans Part No. | Description |
---|---|
88642010 | Support-Package “Engage” – Third Level Support |
88642011 | Support-Package “Getting Started” – Third Level Support |
88643001 | Enhanced Network Management Training |
Offices
- Bonnenbroicher Str. 2-14 41238 Monchengladbach Germany
- Tel: +49 2166 27-2220
- Fax: +49 2166 27-2499
Nexsans cabling solution
- Alsembergsesteenweg 2, b3 B-1501 Buizingen Belgium
- Tel: +32 (0)2 363 38 00 Fax: +32 (0)2 365 09 99
- www.nexans.com/LANsystems
- Sales.ans@nexans.com
Contact
- Nexans LAN Systems
- Tel.: +49 (0) 2166 27 2220
- sales.ans@nexans.com
References