XIAMEN VS135LORA Ultra ToF People Counter User Guide

June 1, 2024
Xiamen

XIAMEN VS135LORA Ultra ToF People Counter

XIAMEN-VS135LORA-Ultra-ToF-People-Counter-product

Packing List

XIAMEN-VS135LORA-Ultra-ToF-People-Counter-fig-1 \(1\)

Button Descriptions

SIM Card Installation

SIM Card Installation (Cellular Version Only)

  • Step 1: Take down the side covers
  • Step 2: Open the slot cover, insert the SIM card (3FF)
  • Step 3: Restore the slot cover back

Power Supply

  • Powered by DC Power Adapter (12V, 2.5A)

Installation

Ceiling Mount
Installation condition: ceiling thickness > 30mm

  • Step 1: Take down the side covers
  • Step 2: Fix wall plugs into ceiling holes
  • Step 3: Remove rubber plugs on the rubber sleeve, connect all required wires
    • Note:
    • Remove the rubber sleeve if waterproofing is not required for easy installation
    • Use round wires
    • Ensure the rubber sleeve and the bottom cover are tightly connected without a gap if waterproofing is required; if necessary, wrap the waterproof tapes around the wires to avoid any gap
    • For non-PoE version devices, tighten the wires to avoid contact with internal modules
  • Step 4: Fix the device to the ceiling with mounting screws
  • Step 5: Restore side covers

Ceiling/Lintel Mount (with Optional VB01 Multifunctional Bracket)

  • Ceiling Mount
  • Lintel Mount

Installation Note:

  • Make sure the ToF sensor is facing down and the tilt angle from the ground is no greater than 15° for the standard version, and no greater than 10° for the high ceiling mount version.
  • Avoid direct Infrared LED light in the detection area.
  • Not suggested to install the sensor close to glass or mirror.
  • Ensure that no other objects are blocking the ToF light within a 50cm radius of the device’s field of view.
  • Though the device is compliant with Class 1 (IEC/EN 60825-1:2014), please DO NOT look at the ToF sensor too closely and directly.
  • Avoid installing the device against the wall and ensure the device keeps away from the wall with a distance of at least 40cm.
  • When you install devices on the top of swinging doors, it is suggested to keep the door normally open.
  • If the door must be normally closed, please install the device on the other side of the door to keep away from the door’s movement.
  • It is suggested to keep away from the door with a distance of at least 40cm.

Access the Web GUI /

VS135 provides a user-friendly web GUI for configuration access via Wi-Fi or Ethernet port. Users need to customize the password when using the device for the first time.

The default settings are as below:

  • Wi-Fi SSID: People Counter_xxxxxx (can be found on the device label)
  • Wi-Fi IP: 192.168.1.1
  • Ethernet IP: 192.168.5.220 (PoE Version Only)

Here are 2 ways of accessing the web GUI:

  • Wireless Method: Enable the Wireless Network Connection on your computer, search for the corresponding Wi-Fi SSID to connect it, and then type 192.168.1.1 to access the web GUI.
  • Wired Method: Connect the device to the computer via an Ethernet port, and assign the IP address of the computer to 192.168.5.xxx manually, then type 192.168.5.220 to access the web GUI.

FCC

FCC Statement

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator& your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

All Software & files can be downloaded from

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals