XIAMEN ACEVCN13P2IW Electric Vehicle AC Charger Instruction Manual
- June 1, 2024
- Xiamen
Table of Contents
- XIAMEN ACEVCN13P2IW Electric Vehicle AC Charger
- Important Safety Instructions
- Product Introductions
- Verify Contents
- Gather Tools
- Plan The Mounting
- Mount the Charging Station
- Wire The Circuit
- Operate Your Device
- Light Codes
- Warranty and Maintenance
- FCC STATEMENT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
XIAMEN ACEVCN13P2IW Electric Vehicle AC Charger
Important Safety Instructions
Overall Warnings & Cautions
WARNING: To avoid fire, injury or death, carefully read and follow the instructions during installation, operation and maintenance.
- DO NOT put fingers into the electric vehicle connector.
- DO NOT use this product if the flexible power cord or EV cable is frayed, the insulation broken, or any other signs of damage.
- DO NOT use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage.
- DO NOT remove cover or attempt to open the enclosure because of the risk of electric shock.
- WARNING: This device should be supervised when used around children.
- WARNING: This device must be grounded.
- WARNING: To avoid a risk of fire or electric shock, do not use this device with an extension cord.
- WARNING: The suitability of the use of flexible cord under CE code, part I, rule 4-012, is to be determined by the local inspection authority.
- WARNING: To reduce the risk of fire, connect only to a circuit provided branch circuit over-current protection under the CSA C22.1–15 Canadian Electrical Code, Part 1 (Canada) or NOM-001-SEDE Electrical installations (utility) (Mexico) or ANSI / NFPA 70 National Electrical Code (USA).
Circuit Breaker Options table
Output Amperage (A)| 16A| 32A| 40A| 48A| 70A| 80A
Circuit Breaker Options (A)| 20A| 40A| 50A| 60A| 90A| 100A
Installation Requirements
- WARNING: Disconnect electrical power before installing the charging station.
- WARNING: Be sure to preview the user manual and ensure local building and electrical codes are reviewed before installing the AC charger.
- WARNING: The AC charger should be installed by a qualified technician according to the user manual and local safety regulations.
- CAUTION: Use appropriate protection when connecting to the main power distribution cable.
- CAUTION: Type B, C or D breaker with the rating current for the table should be installed in the upstream AC distribution box.
- CAUTION: The device shall be mounted at a height between 2 feet and 4 feet from the ground.
- CAUTION: Please keep the charger in a clean area with low humidity. Not recommended to be installed in coastal environments with high humidity or high dust.
Daily Maintenance
- CAUTION: Avoid moisture or water in the charger. If there is water or moisture ingress in the charger, it is necessary to immediately power off to avoid immediate danger, and notify the professionals to carry out maintenance before next use.
- CAUTION: Please use the charger properly. Do not hit or press hard on the enclosure. If it is damaged, please contact a professional technician.
- CAUTION: Avoid placing the charger near hot objects and at high-temperature locations and away from dangerous substances such as flammable gases and corrosive materials.
- CAUTION: Do not put heavy objects on the charger to avoid danger.
Product Introductions
CAUTION: Avoid placing the charger near hot objects and at high- temperature locations and away from dangerous substances such as flammable gases and corrosive materials.
Basic Interface
Basic Dimension
Enclosure
Wall-Mounted Bracket
Specifications
Model Number | JNT-EVC Version |
---|---|
Rated Input Voltage | 208/240VAC |
Rated Output Current | 16/32/40/48/70/80A |
AC Power Frequency | 50-60 Hz |
Input Protection | UVP, OVP, RCD, SPD, Ground Fault Protection |
Output Protection | OCP, OTP, Control Pilot Fault Protection |
Output Interface | SAE J1772AC Charging Connector |
Storage Temperature | -40°F to 158°F |
Operation Temperature | -22°F to 122°F |
Relative Operation Humidity | 95% RH Maximum |
Relative Storage Humidity | 95% RH Maximum |
Network Connection | LAN Version /Wi-Fi Version |
Internet Function | 10M / 100M Base-T |
Wi-Fi Function | 802.11 b/g/n |
3G/4G Function | / |
Cable Length | 18ft (25ft optional) |
Protection Level | Type 3 |
Installation Type | Wall-Mounted |
Altitude | ≤ 6561ft |
Status Indication | Red, Green, Blue LED |
Verify Contents
Check the box to ensure you have this installation guide and these parts:
USER MANUAL
No. | Product Name | Quantity | Description |
---|---|---|---|
1 | AC Charger | 1 | With attached input power cable |
and output charging cable
2| User Manual| 1| Please read carefully before use
3| Wall-Mounted Bracket| 1| For mounting the charging station to
the wall/structure
4| M5 Anti-Theft Round
Head Screws
| 2| For securing the charging station to
the Mounting Bracket
5| M6 Hexagonal Expansion
Screws
| 4| For installing the Mounting Bracket
to the wall/structure
6| Allen Wrench| 1| For tightening M5 Screws
7| Corrugated Mounting
Template
| 1| For easy drilling of 4 screws holes
for wall-mounted bracket.
8| RFID Card (Optional)| 2| Control the charger start/stop
Gather Tools
Tools required before installing the Wall-Mounted charger, gather the following tools:
- Wire stripper
- Adjustable Wrench
- Voltmeter or digital multi-meter (for measuring AC voltage at the installation site)
- Level
- Pencil or marker
- Drill
- Phillips screwdriver
Note: The above tools are very important, please gather them all.
Plan The Mounting
- WARNING: In areas with frequent thunderstorms, add surge protection at the service panel for all circuits. Ensure all power and ground connections, especially those at the breaker and bus bar, are clean and tight.
- CAUTION: Not recommended to be installed in coastal environments with high humidity or high dust.
STEP 4
Select the appropriate mounting location with electrical capacity:
- Ensure the owner has chosen a mounting location that allows the charging cable to reach the car’s charging port while still providing slack.
- The device must be anchored into a mounting such as 3.14’’ x 5.11’’ stud or a solid wall.
- The device shall be mounted at a height between 2 feet and 4 feet from the ground.
STEP 5
- Drill 4 Screw Holes with a diameter of 0.32’’and a depth of 2.04’’ by using our mounting template. Please drill screw holes in the direction of the template arrow.
Mount the Charging Station
STEP 1
- Use 4 sets Hexagonal Expansion Screws to secure the wall-mounted bracket on the wall. Then level the brackets.
- Align the rear notch of the charger with the wall-mounted bracket and fit the screw holes of the right and left side.
- Tighten two M5 anti-theft screws to complete the installation.
STEP 4
- Overall outlook picture after installation.
Wire The Circuit
- WARNING: This device must be grounded. Disconnect electrical power prior to installing the charging station.
- WARNING: Improper connection of the equipment-grounding conductor would result in a risk of electric shock. Check with a qualified electrician or serviceman if you are not sure whether the product is properly grounded. Do not modify the plug provided with the product – if it doesn’t fit the outlet, have a proper outlet installed by a qualified electrician.
- CAUTION: Use appropriate protection when connecting to the main power distribution cable.
For safe use of electricity, please set circuit breaker protection in the input part of EV Charger The wiring is not complicated, just need to follow the instructions below: Connect the L1 lead to the grid L1, connect the L2 lead to the grid L2, connect the PE lead to the grid PE.
Circuit Breaker Options table
Output Amperage (A)| 16A| 32A| 40A| 48A| 70A| 80A
Circuit Breaker Options (A)| 20A| 40A| 50A| 60A| 90A| 100A
Operate Your Device
- WARNING: This device should be supervised when used around children.
- CAUTION: Please use the charger properly. Do not hit or press hard on the enclosure. If the case is damaged, please contact a professional technician.
- CAUTION: Do not put heavy objects on the charger to avoid danger.
Operating Steps with Plug and Charge
STEP 1
Standby Mode: After being powered on, the lights will be all on, blue light
(READY), green light (CHARGE) and red light (FAULT). Then the blue light
(READY) is constantly on in standby mode.
STEP 2
Plug the Charging Connector: Please plug the charging connector into the vehicle charging inlet.
STEP 3
Charging: The green light (CHARGE) turns to flash automatically, charging is in process.
- If the red light (FAULT) is on, plug the vehicle connector again.
- If red light is still on, please refer to “Error and Warning Messages”.
STEP 4
Charging finished: When the charging is finished, the green light (CHARGE) is constantly on, pull out the charging connector.m
Operating Steps with RFID (Optional)
CAUTION: Please keep your RFID card properly to avoid unnecessary loss.
STEP 1
Standby Mode: After power-on, blue light (READY), green light (CHARGE)
and red light (FAULT) all on. The blue light (READY) is constantly on when in
standby mode.
STEP 2
Ready to charge: Please plug the charging connector into the vehicle charging inlet. When the green light (CHARGE) is constantly on, the user can swipe the RFID Card
STEP 3
Swipe the RFID Card: Swipe the RFID card first and plug in the charging connector within 120 seconds, otherwise you need to swipe the RFID card again.
STEP 4
Charging: The green light (CHARGE) turns to flash automatically, charging is in process.
- If the red light (FAULT) is on, plug in the charging connector again.
- If red light is still on, please refer to “Error and Warning Messages”.
STEP 5
Charging finished: When the charging is finished or swipe your RFID card, the green light (CHARGE) is constantly on. Please press the button on connector and pull out the charging connector
Light Codes
After Start UP
Standby,
waiting to plug in
| Waiting to charge,
communicating
with vehicle
|
Charging in progress
|
Finished charging
|
Fault
---|---|---|---|---
Solid Blue| Solid Green| Green Blinking| Solid Green| Solid Red
Error and Warning Messages
Status | Red | Remark |
---|
Input OVP
|
1 flash followed by 3 sec pause
|
Auto Recover
Input UVP
|
2 flashes followed by 3 sec pause
|
Auto Recover
Output OCP
|
3 flashes followed by 3 sec pause
|
Auto Recover
OTP
|
4 flashes followed by 3 sec pause
|
Auto Recover
RCD Abnormal
|
5 flashes followed by 3 sec pause
|
Auto Recover
Ground Fault
|
6 flashes followed by 3 sec pause
|
Auto Recover
Control Pilot Fault
|
Flicker
|
Auto Recover
Emergency Fault
|
Constantly Bright
|
Rotate to Reset Emergency Button
MCU Self-Test Fail
|
Constantly Bright
|
Contact Customer Service
RCD Self-Test Fail
|
Constantly Bright
|
Contact Customer Service
Relay Self-Test Fail
|
Constantly Bright
|
Contact Customer Service
RCD Abnormal Stop Charging
|
Constantly Bright
|
Contact Customer Service
Output OCP Stop Charging
|
Constantly Bright
|
Contact Customer Service
OTP Stop Charging
|
Constantly Bright
|
Contact Customer Service
Warranty and Maintenance
- The warranty period for this charger is three years.
- During the warranty period for any malfunction under normal use according to the user Manual (to be determined by certified maintenance technicians of sellers), the product shall be repaired free of charge. Except for the following situations, the charger shall be subject to the above warranty terms:
- The warranty certificate cannot be provided or the contents of the warranty certificate are modified or inconsistent with the label indication of the repaired product.
- Those who are unable to provide valid proof of purchase.
- Those who exceed the manufacturer’s specified warranty period.
- Those who damage the product due to not following the product service instructions for use, maintenance, and storage.
- Damage or malfunction caused by an external object entering.
- Unauthorized repair, disassembly, or modification.
- Damage caused by force majeure (such as lightning, excessive voltage, earthquake, fire, flood, etc.).
- Malfunction and damage caused by other unavoidable external factors. Malfunctions and damage caused by improper use of equipment, such as water or other solutions entering into the equipment.
- Malfunction and damage caused by the grid power supply and voltage which is not specified for use with the charger equipment.
The above guarantees shall be made solely, and no other express or implied warranties shall be made (including the implied warranties of merchantability, particular and applicable reason- ableness and adaptability, etc.) whether in the contract, civil negligence, or other aspects, the Company shall not be responsible for any special, incidental or consequential damages.
FCC STATEMENT
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, under part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used under the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct
the interference at his own expense.
- WIFI module: Contains IC:21098-ESPWROOM32
- WIFI module: Contains FCC ID:2AC7Z-ESPWROOM32
To satisfy FCC RF exposure requirements, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended.
ISED Regulatory Compliance
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with IC RSS‐102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 30cm between the radiator and your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>