elko ep 40-60 Key Fob 6 Buttons White User Manual
- June 13, 2024
- ELKO ep
Table of Contents
- Elko ep 40-60 Key Fob 6 Buttons White
- Product Information
- Product Usage Instructions
- Characteristics
- Indicators, settings
- Radiofrequency signal penetration through various construction materials
- Insertion and replacement of a battery
- Technical parameters
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Elko ep 40-60 Key Fob 6 Buttons White
Product Information
- Product Name: RF KEY – 40/60
- Model: EN 4/6 Key fob (DE 4/6 Kanal Steuerung – Fernbedienung)
- Characteristics:
- Newly produced drivers work in the RFIO2 data protocol mode.
- The mode in which the controllers are working can be changed and indicated after an 8-second press of the ‘Prog’ button.
- The LED diode under the push button indicates the chosen mode by different flashing intervals.
- RFIO2 mode is indicated by a double flash (flash, flash, gap, flash, flash), while compatibility mode is indicated by a fast flash (flash, flash, flash, flash, flash).
- Radiofrequency signal penetration varies through different construction materials.
- Technical Parameters:
- Supply voltage: 3 V battery (CR2032)
- Battery life: Not specified
- Transmission indication: Red LED
- Number of buttons: 4 (RF KEY-40) or 6 (RF KEY-60)
- Communication Protocol: RFIO2
- Frequency: Not specified
- Signal transmission method: One-way addressed message
- Range: Up to 200 m in the open (outdoor) environment
- Operating temperature: Not specified
- Operating position: Not specified
- Color design: Not specified
- Protection: IP20
- Pollution degree: 2
- Dimensions: 71 x 31 x 8 mm
- Weight: 17 g
- Related standards: EN 60730, EN 63044, EN 300 220, EN 301 489
Product Usage Instructions
To update the controller actuators in RFIO2 mode, follow these steps:
- Switch the actuator to update mode according to the actuator’s instructions.
- Switch the controller to update mode by pressing and holding the ‘Prog’ button for 8 seconds.
- The LED diode under the push button will be on while the button is pressed.
- After 8 seconds, the LED diode will indicate the chosen mode by different flashing intervals.
- The mode changes to the inverse mode after each pressing of the button.
To insert or replace the battery, follow these steps:
- Using a Phillips head screwdriver, remove the screw on the back of the transmitter.
- Remove the rear cover.
- Slide the CR2032 battery into the battery holder, observing the polarity.
- Replace the rear cover and replace the screw.
Note: When installing the iNELS RF Control system, ensure a minimum
distance of 1 cm between each unit. Between individual commands, there should
be an interval of at least 1 second.
Achtung: Bei der Installation Aktoren iNELS RF Control muss es der
Mindestabstand 1 cm geachtet sein. Zwischen aufeinanderfolgenden
Befehlseingaben sollte mindesten 1 s Abstand liegen.
Characteristics
- Key fob-sized remote control, available in black and white.
- When the button is pressed, it sends the set command (ON / OFF, dimming, time on / off, lower / raise).
- RF KEY-40: 4 buttons, each of which allows you to control an unlimited number of components.
- RF KEY-60: 6 buttons, each of which allows you to control an unlimited number of components.
- Replaceable battery (3 V CR 2032) with a service life of approx. 5 years (depending on the frequency of use).
Indicators, settings
- Newly produced drivers work in the RFIO2 data protocol mode.
- These drivers are loaded in the actuators in a different way than before. Among other things, it eliminates the risk of inadvertently loading another randomly occurring controller within range. Drivers can still be switched to so-called compatibility mode, and loaded in a simpler (older way).
- The mode in which the controllers are working is changed and indicated after 8 seconds by pressing the ‘Prog’ button. The LED diode under the pushbutton is on when the button is kept pressed; after 8 seconds it indicates the chosen mode by different flashing intervals. The mode changes to the inverse mode after each pressing of the button.
RFIO2 mode
- Double flash (flash, flash, gap, flash, flash)
Compatibility mode
- Flash fast (flash, flash, flash, flash, flash)
Update the controller actuators in RFIO2 mode
- If the controller is used in RFIO2 mode, then to update the controller actuators, it is necessary to switch not only the actuator to the update mode (according to the instructions for the actuator) but also the controller in the following way:
- Press the programming button on the controller, and converter for more than 1 second and release it.
- The LED diode starts flashing in second intervals. Leave the LED flashing to activate the programming mode on the actuator by pressing the programming button for more than 1 second. The actuator is also put into the programming mode.
- The desired function can be selected by the respective number of presses of the control pushbuttons or inputs (of the converter).
- The programming modes on the controller and actuator can be closed by pressing the programming button for less than 1 second. The LEDs stop flashing.
- The programming button is operated with a suitable thin tool (Ø1 mm, e.g. paper clip).
Radiofrequency signal penetration through various construction materials
80 – 95 % | 80 – 90 % | 60 – 90 % | 20- 60 % | 0 – 10 % |
---|---|---|---|---|
wooden structures with plasterboards | common glass | brick walls | reinforced | |
concrete | metal partitions |
Insertion and replacement of a battery
- Using a Phillips head screwdriver, remove the screw on the back of the transmitter. Remove the rear cover.
- Slide the CR2032 battery into the battery holder. Observe the polarity.
- Replace the rear cover and replace the screw.
Technical parameters
RF KEY-40 RF KEY-60
Supply voltage: | 3 V battery / Batterie CR 2032 |
---|---|
Battery life: | about 5 years depending on the frequency of use / ca. 5 Jahre |
je nach
Transmission indication:| red/rote LED
A number of buttons:| 4| 6
Communication Protocol:| RFIO2
Frequency:| 866–922 MHz
Signal transmission method:| one-way addressed message
Range:| in the open up to 200 m / bis zu 200 m (im Freien)
Other data|
Operating temperature:| -10 … +50 °C
Operating position:| any / beliebig
Colour design:| white, black / Weiß, schwarz
Protection:| IP20
Pollution degree:| 2
Dimensions:| 71 x 31 x 8 mm
Weight:| 17 g
Related standards:| EN 60730, EN 63044, EN 300 220, EN 301 489
Attention:
- When you install the iNELS RF Control system, you have to keep a minimal distance of 1 cm between each unit.
- Between the individual commands must be an interval of at least 1s.
Safe handling
- When handling a device unboxed it is important to avoid contact with liquids.
- Never place the device on the conductive pads or objects, avoid unnecessary contact with the components of the device.
Warning
- The instruction manual is designated for mounting and also for the user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualifications upon understanding this instruction manual and the functions of the device, and while observing all valid regulations. The trouble-free function of the device also depends on transportation, storage, and handling. In case you notice any sign of damage, deformation, malfunction, or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts, or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives, and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to the transmissivity of the RF signal, observe the correct location of
- RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation in exteriors and humid spaces. They must not be installed into metal switchboards and into plastic switchboards with metal doors – transmissivity of RF signal is then impossible.
- RF Control is not recommended for pulleys etc. – the radiofrequency signal can be shielded by an obstruction, interfered with, a battery of the transceiver can get fl at, etc., and thus disable remote control.
- ELKO EP declares that the RF KEY type of radio equipment complies with Directive 2014/53 / EU.
The full EU Declaration of Conformity is available at:
- www.elkoep.com/controller-%E2%80%93-key-fob-rf-key-40b
- www.elkoep.com/controller-%E2%80%93-key-fob-rf-key-40w
- www.elkoep.com/controller-%E2%80%93-key-fob-rf-key-60b
- www.elkoep.com/controller-%E2%80%93-key-fob-rf-key-60w
- ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
- Tel.: +420 573 514 211, e-mail:elko@elkoep.com, www.elkoep.com