BEGA 51061.1 Track Spotlight for Indoor Use Instruction Manual

June 13, 2024
BEGA

Track spotlight for indoor use
51 061.1

BEGA 51061 1 Track Spotlight for Indoor Use - cover

Instructions for use

Application

Ceiling mounted track spotlight · indoor luminaire for 3-phase Euro standard- Plus ® track systems. The optical system of the washer is swivel mounted and rotatable.
Symmetrical wide beam light distribution. Optical diffuser filters are available as accessories for changing the light distribution. With BEGA Hybrid Optics® : Highly efficient and low-loss light distribution, thanks to reflector and optical lens.

Product description

GENIUS Track spotlight with adapter Cast aluminum luminaire housing, finish Color velvet white, Polycarbonate track adapter with integrated LED power supply unit Trim ring · Chrome finish Safety glass, with internal optical diffuser filter Optical silicone lens · BEGA Hybrid Optics ® Reflector surface made of pure aluminum LED power supply unit
220-240 V ~ 50/60 Hz DALI-controllable Basic insulation is provided between the mains and control cables
Safety class II Icon
****– Conformity mark
Weight: 1.1 kg
This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 31.6 W
Luminaire connected wattage 37.5 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 35 °C

51 061.1 K3

Module designation LED-0800/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 4220 lm
Luminaire luminous flux 3010 lm
Luminaire luminous efficiency 80,3 lm / W

51 061.1 K4

Module designation LED-0800/930
Colour temperature 4000 K
Colour rendering index CRI > 90
Module luminous flux 4285 lm
Luminaire luminous flux 3056 lm
Luminaire luminous efficiency 81,5 lm / W

Light technique

Track spot · surface washer with adjustable optical system.
Optical system 0-340° swivel-mounted and ± 310° infinitely rotatable around the vertical luminaire axis.
Symmetrical wide beam light distribution.
Half beam angle 36°
The symmetrical light cone can be changed to a flat beam, symmetrically diffuse or asymmetrical light distribution for special lighting applications by replacing the optical diffuser  filter (standard) – accessoires.

For flat beam light distribution: Diffusing filter 13 288
For symmetrical diffuse light distribution: Diffusing filter 13 312
For asymmetrical light distribution: Diffusing filter 13 311

BEGA 51061 1 Track Spotlight for Indoor Use - Light technique
1| | | BEGA 51061 1 Track
Spotlight for Indoor Use - Light technique 4
---|---|---|---
standard| flat beam| symmetrically diffuse| asymmetrical

The light cone can be adjusted by ±360° by turning the trim ring.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
The track spotlight with adapter is ready for operation in 3-phase EUROSTANDARD-PLUS® track systems.
The mounting is done without tools in the bus bar.

IMPORTANT:
Ensure that the adapter’s two lateral stays are located on the same side as the matching guide profile of the track before installing the adapter in the 3-phase EUROSTANDARDPLUS ® track system.
To select the phase ( 1 2 3 ) the turning knob on the rear side of the adapter has to be operated accordingly.
Screw enclosed fastening ring (a) with attached reflector into the luminaire housing by turning it clockwise until it stops, so that it is fixed by clamping.

BEGA 51061 1 Track Spotlight for Indoor Use - Light technique
5

Clip the trim ring with glass and internal optical diffuser filter (b) onto the luminaire housing by applying slight pressure.

BEGA 51061 1 Track Spotlight for Indoor Use - Light technique
6

Place the surface washer adapter flush on the conductor rail in the desired position.
Push the two fixing levers on the underside of the adapter to the right until they click into their end position.
Set the desired LED beam direction by turning and tilting the luminaire housing.
Move the two fixing levers in opposite directions until they disengage to unlock the adapter.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
Disconnect the system and open the luminaire.
Uninstall the reflector.
Please follow the installation instructions for the LED module.
Install the reflector. Defective glass must be replaced. Close the luminaire.

Accessories · Optical diffuser filter

13 288 Diffuser filter flat beam
13 312 Diffuser filter symmetrical, diffuse
13 311 Diffuser filter asymmetrical

For the accessories a separate instructions for use can be provided upon request.

Spares

Prismatic film 15 000 684
Fastening ring reflector 20 000 086 B5
LED power supply unit DEV-0437/900i
LED module 3000 K LED-0800/930
LED module 4000 K LED-0800/940
Trim ring with glass 75 004 844
Reflector unit 76 001 608 .1M