BEGA 50063.5 Wall Luminaire for Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
50 063.5
Wall luminaire for indoor use
Instructions for use
Application
Wall luminaire · indoor luminaire with integrated power supply unit for many
lighting tasks in interior applications.
The light emits upwards and downwards.
Product description
Luminaire made of aluminium alloy
Finish Colour velvet black
Crystal glass with white matt finish 2 elongated fixing holes
Width 4.5 mm · 65 mm spacing 1 cable entry for mains supply cable up to ø 10,5
mm
Connecting terminal 2.5@ with plug connection
Earth conductor connection
BEGA Ultimate Driver®
LED power supply unit 220-240 V 0/50-60 Hz DC 176-264 V
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Impact strength IK07
Protection against mechanical impacts < 2 joule
–Safety mark
– Conformity mark
Weight: 1.0 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage| 7.6 W
Luminaire connected wattage| 9 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 40 °C
50 063.5 K3
Module designation| 2x LED-0276/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 1330 lm
Luminaire luminous flux| 541 lm
Luminaire luminous efficiency| 60,1 lm / W
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or revamping.
Undo the screws and lift off the luminaire top.
Loosen LED plug connection.
Lead the mains supply cable through the cable entry of the luminaire base.
Note position of application of the luminaire “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection to
terminal (plug connection).
Make earth conductor connection between luminaire top and luminaire base.
Push LED plug into coupler as fa as it will go.
Install the luminaire top, press-on and manually tighten screws evenly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
LED power supply unit| DEV-0304/350
LED module 3000 K| LED-0276/930
Technical amendments reserved