BEGA 50068.3 Linear Wall Luminaire
DIMENSIONS
Instructions for use
Application
- Free radiating wall luminaire · indoor luminaire with hand-blown three-ply opal glass for a soft and uniform light distribution.
- The elongated design of this wall luminaire particulary provides suitability for installation on pillars, columns and for the front surface of walls, as well as for recesses or profiles.
- The luminaire may be installed horizontally or vertically.
Product Description
- Metal luminaire housing, finish Chrome
- Hand-blown opal glass
- The electrical equipment can be hinged 2 mounting holes ø 6 mm
- Distance apart 300 mm
- Jointing sleeve with cable entry for mains supply cable up to ø 14 mm, max. 5 x 1.5@
- Connecting terminals 2.5@
- Earth conductor terminal
- LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-276 V
- During DC operation the LED power is reduced to 15 %
- DALI-controllable
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets
- Impact strength IK03
- Protection against mechanical
- impacts < 0.35 joule
- – Safety mark
- – Conformity mark
- Weight: 3.0 kg
- This product contains light sources of energy efficiency class(es) D
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Installation
- LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
- Undo hexagon socket (wrench size 5) in the locking cap and remove it.
- The opal glass can now be hinged together with the electrical equipment to the front.
- Remove opal glass.
- Note position of application of the luminaire »arrow down«.
- Drill mounting holes into the mounting surface – spacing 300 mm and turn in enclosed or suitable fixing screws.
- For the electrical connection undo the screw connection at the line connector and remove terminal block.
- Make earth conductor connection and electrical connection.
- Make connection of the phase with the L marked, the neutral wire at the N marked and earth conductor at the PE marked connecting terminal.
- For digital actuation please use the two connecting terminals DA. The luminaire will work with full light output if these terminals are not assigned.
- Bolt together both screw cable glands firmly.
- Hook luminaire into the fixing screws and tighten.
- Slide opal glass over the lamp and fasten with the locking cap.
- Make sure that the gaskets are positioned correctly.
Lamp
- Module connected wattage 19.2 W
- Luminaire connected wattage 22.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C 50 068.3 K3
- Module designation
- 2x LED-0626/930 + 2x LED-0627/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 3210 lm
- Luminaire luminous flux 2286 lm
- Luminaire luminous efficiency 101,6 lm / W
Cleaning · Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt.
- Defective glass must be replaced.
Replacement of the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Defective glass must be replaced.
- Close the luminaire.
Spares
- Spare glass 11 002 763 .1R G
- LED power supply unit DEV-0158/700i
- LED module 3000 K LED-0627/930
- LED module 3000 K LED-0626/930
- Gasket glass 2x 83 000 788
BEGA Gantenbrink-Leuchten KG
- Postfach 31 60
- 58689 Menden
- info@bega.com
- www.bega.com
References