BEGA 84 088 In Ground Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA 84 088 In Ground Luminaire Instruction Manual
In Ground Luminaire

Instructions for use

Dimension

Application
In-ground luminaire with symmetrical light distribution directed upwards for accentuated illumination of private gardens. Luminaire resistant to foot traffic for flush installation in soil, lawn or gravel. Luminaire must not be overrun by vehicles.

Product description

  • Luminaire housing made of
  • glass-fibre reinforced synthetic
  • Cover frame made of stainless steel,
  • steel grade number 1.4301
  • Clear safety glass
  • Reflector surface made of pure aluminium 1,8m water-resistant connecting cable 07RN8-F 3G1@ with implemented water stopper and 1.2m PVC cable conduit
  • BEGA Ultimate Driver®
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect
  • temperature-sensitive components
  • Safety class I
  • Protection class IP 67
  • Dust-tight and protection against temporary immersion
  • Pressure load 150 kg (~1,500 N)
  • Impact strength IK08
  • Protection against mechanical impacts < 5 joule r – Safety mark c – Conformity mark
  • Weight: 0.95 kg This product contains light sources of energy efficiency class(es) D, E

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out b a qualified electrician. We recommend fuse protection via a residual current circuit breaker to be provided by the customer.   The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp
Module connected wattage : 4.1 W
Luminaire connected wattage : 5.2 W
Rated temperature: ta=25 °C
Ambient temperature ta : max=30 °C

84 088K27
Module designation LED :-0394/827
Colour temperature: 2700 K
Colour rendering index : CRI >80
Module luminous flux: 575 lm
Luminaire luminous flux : 275 lm
Luminaire luminous efficiency : 52,9 lm/W

84 088K3
Module designation LED :-0394/830
Colour temperature :3000 K
Colour rendering index: CRI >80
Module luminous flux: 630 lm
Luminaire luminous flux; 301 lm
Luminaire luminous efficiency : 57,9 lm/W

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Installation
l Luminaire housing must not be installed in heat-insulating material. Sufficient drainage (e.g. gravel, stone chippings) must be provided under the luminaire. 0.3 m of cable should be left under the luminaire housing so that the luminaire could be removed during maintenance work. Insert the luminaire flush into the soil surface. To protect the luminaire connecting cable from damage push the enclosed cable conduit over the cable.
The electrical connection at the luminaire connecting cable must be carried out on site according to the protection class and safety class. We recommend to use a distribution box 70 730 or 71 053

Cleaning · Maintenance
After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form. When using stainless steel cleaners, please read the directions carefully. Cleaning agents containing hydrochloric acid and chlorides should never be used. We recommend cleaning the luminaires regularly

Please note:
Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

Disconnect the system.
Lift luminaire out of the ground surface and place it with the glass side facing downwards onto an even and clean underlay. Undo hexagon nuts and lift luminaire housing. LED modules can be replaced now. Please follow the installation instructions for the LED module. Check all hexagon nuts and threads thoroughly and grease them. Check the gasket and replace, if necessary. A broken glass must be replaced. Insert reflector. Insert glass with stepped side turned upward into the luminaire housing. Make sure that the gasket is positioned correctly. Place cover frame onto glass step and tighten firmly nuts crosswise. Torque = 2 Nm.

Accessories
70 730 Distribution box for installation in soil with 7 cable entries Connection terminals 5 x 4@

A separate instructions for use can be provided upon request.

Spares
Spare glass : 14 001 360
LED power supply unit: DEV-0303/350
LED module 2700 :  LED-0394/827
LED module 3000: K LED-0394/830
Reflecto r: 76 001 962
Gasket glass: 83 001 851

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals