Dimension
Product description
Recessed luminaire without power supply unit Luminaire housing made of cast aluminium Installation housing is made of glass-fibre reinforced polyamide with 2 fastening springs Reflector surface made of pure aluminium Optical silicone lens · BEGA Constant Optics® Ceiling trim ring made of metal, Colour white Safety glass
Recessed opening ø 188mm
Required installation depth 130mm
1 connecting cable with strain relief and plug connector system for BEGA power supply unit, on/off or DALI
Safety class III
– Conformity mark
Weight: 1.6 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage 25 W
Luminaire connected wattage 29 W
Rated temperature ta=25 °C
Ambient temperature ta max=35 °C
50 441.1K3
Module designation LED-0785/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 4365 lm
Luminaire luminous flux 3339 lm
Luminaire luminous efficiency 115,1 lm/W
Lighting technology
Half beam angle 65/68°
Installation
Luminaire housing must not be installed in heat-insulating material.
A separate power supply unit is required to operate the luminaire.
For connection to external LED-power supply unit – accessory 13 145 or 13 171 – the luminaire is equipped with a 2-pin connector. Note operating instructions of the LED-power supply units.
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the installation housing in the recessed opening is achieved by using two adjustable springs.
Installation into inserted ceilings:
A recessed opening of 188 mm is necessary to accept the installation housing. Recessed depth min. 130 mm.
Compress the fastening springs of the installation housing against their spring pressure on both sides towards the housing and slide the installation housing into the recessed opening.
The fastening springs catch the ceiling panel from the back side. Minimum thickness of the ceiling panel is 5 mm. If minimum thickness of the panel is less than 5 mm it must be reinforced from the reverse side. Maximum thickness of the ceiling panel must be no more than 25 mm.
Fix the installation housing in the ceiling panel with two enclosed fastening screws (see sketch).
Connect to the LED power supply unit. Route the LED power supply unit through the installation housing and place it in the suspended ceiling.
Connect the 2-pin plug connector between luminaire and external LED power
supply unit.
Press together the two internal fixing sliders inside the luminaire housing.
Push the luminaire housing to the end of the installation housing and then release the fixing sliders.
This mechanism ensures that the luminaire housing sits securely inside the installation housing.
Ensure correct directionality towards the area to be illuminated.
Installation housing and external LED power supply unit must not be
installed in heat-insulating material.
Please use the protective gloves provided for the installation to prevent finger prints on the reflector.
Insert the reflector complete with the silicone lens into the three recessed rims of the luminaire housing.
Make sure that the positioning bar of the reflector is placed inside the correct recessed rim. That will ensure that the reflector is positioned correctly in relation to the LED.
Carefully insert the locking bars of the ceiling trim ring into the 3 remaining openings in the luminaire housing and fix the ceiling trim ring with a twist to the right.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Close the luminaire.
Accessories
Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.
13 145 Power supply unit on/off
13 171 Power supply unit DALI
The power supply units are only suitable for the operation of one LED luminaire.
For the accessories a separate instructions for use can be provided upon request.
Spares
LED module 3000 K LED-0785/830
Trim ring 75 002 951
Reflector 76 001 638M
Customer Support
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>