BEGA 77019 Recessed Floor Light LED Instructions

June 13, 2024
BEGA

77 019
IP 68
In-ground luminaire
BEGA 77019 Recessed Floor Light LED -

Instructions for use

Application
Floodlight with asymmetrical light distribution for recessed mounting in compacted surfaces, paths and places.
Drive-over luminaire for vehicles with pneumatic tyres.
Please note:
Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.

Product description
Cover ring Luminaire housing made of stainless steel and cast stainless steel Steel grade number 1.4301 Clear safety glass Reflector made of pure anodised aluminium 2 mounting holes ø 5 mm Distance apart 120 mm 1,8 m water-resistant connecting cable
05RN8-F 3 G 1@ with implemented water stopper and 1.2 m PVC cable conduit BEGA Ultimate Driver®  LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V BEGA Thermal Switch® Temporary thermal shutdown to protect temperature- sensitive components Safety class I Protection class IP 68 10 m Dust-tight and water pressure tight Maximum submersion depth 10 m Not suitable for permanent operation under water Pressure load 2,000 kg (~20 kN) Impact strength IK10 Protection against mechanical impacts < 20 joule Maximum surface temperature 20 °C (measured according to EN 60598 of ta 15 °C)
– Safety mark
**** – Conformity mark
Weight: 1.6 kg
This product contains light sources of energy efficiency class(es) C

Lighting technology
Half beam angle 34/35°

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
We recommend fuse protection via a residual current circuit breaker to be provided by the customer.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Notice prior to installation:
To accept the maximum pressure load of 2,000 kg (~20 kN) a proper foundation must be provided by the customer.
The pressure load is transferred to the foundation by this luminaire housing provided at site.
The foundation must be carried out on firm subgrade.
In order to obtain a firm stableness, the luminaire housing must be firmly concreted in.

Installation

Position luminaire housing on the foundation (as described above) and fix it with enclosed or any other suitable fixing material.
Note alignment of the surface to be illuminated.
The electrical connection at the luminaire connecting cable must be carried out on site according to the protection class and safety class.
We recommend to use a distribution box 70 730.
If the luminaire connecting cable is laid in the soil the enclosed protective conduit must be used.
After finishing the ground works remove protection film from the luminaire cover.
Tighten the screws in the trim ring evenly crosswise.
Torque = 3 Nm.

Cleaning · Maintenance

After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form. When using stainless steel cleaners, please read the directions carefully. Cleaning agents containing hydrochloric acid and chlorides should never be used. We recommend cleaning the luminaires regularly.

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Lamp

Module connected wattage 3 W
Luminaire connected wattage 4.1 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 50 °C
When installed in heat-insulating  material  ta max = 35 °C

77 019 K27
Module designation| LED-0291/827
Colour temperature| 2700 K
Colour rendering index| CRI > 80
Module luminous flux| 535 lm
Luminaire luminous flux| 369 lm
Luminaire luminous efficiency| 90 lm / W
77 019 K3
Module designation| LED-0291/830
Colour temperature| 3000 K
Colour rendering index| CRI > 80
Module luminous flux| 550 lm
Luminaire luminous flux| 379 lm
Luminaire luminous efficiency| 92,4 lm / W
77 019 K4
Module designation| LED-0291/840
Colour temperature| 4000 K
Colour rendering index| CRI > 80
Module luminous flux| 565 lm
Luminaire luminous flux| 389 lm
Luminaire luminous efficiency| 94,9 lm / W

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA  replacement modules correspond to thoseof the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the electrical installation.
Clean dirt and deposits from key openings of screw head. Do not use a high pressure cleaner. Open the luminaire and clean. Use only solvent-free cleansers. Dismantle the LED-board unit and disconnect the connecting cable at the terminal of the LED board unit.
Make electrical connection of the new LED board unit.
Fix LED board unit in the luminaire housing.
Check all screws and threads thoroughly and grease. Check the gasket and replace, if necessary. The luminaire housing must be completely clean and absolutely dry. Close the luminaire. Torque = 3 Nm. Chemicals which have a corroding effect must not affect the
luminaire housing.

Accessories

70 730 Distribution box
The distribution box is meant for installation in the soil and allows a junction from the supply cable to the luminaire and through-wiring to the next luminaire.
After the electrical connection the distribution box is filled up with gel and closed.

Spares

Spare glass 14 000 918
LED power supply unit DEV-0303/350
LED module 2700 K LED-0291/827
LED module 3000 K LED-0291/830
LED module 4000 K LED-0291/840
Reflector 76 001 146
Gasket insert 83 001 437
Gasket 83 001 786

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References