BEGA 50807.1 LED Wall Luminaire Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
BEGA 50807.1 LED Wall Light
Product Information
Product Description| Luminaire housing made of aluminium, finish Color velvet
white
---|---
Cable Entry| 1 cable entry for through-wiring
Mains Cable Connection| Connection terminal 2.5@
LED Power Supply Unit| 220-240V x 0/50-60Hz DC 176-280V
DALI Control| DALI-controllable Number of DALI addresses: 1
Safety Class| Impact strength IK04
Weight| 9.3kg
Energy Efficiency Class| D (light sources)
Product Usage Instructions
To use the product:
- Ensure that the installation and operation of the luminaire comply with national safety regulations.
- Only a qualified electrician should carry out the installation and commissioning.
- Do not modify the luminaire without proper authorization, as the person responsible for modifications will be considered the manufacturer.
- For additional protection against overvoltage and other electrical disturbances, it is recommended to use separate overvoltage protection components. These can be found on the manufacturer’s website at www.bega.com.
Application
- Wall luminaire · indoor luminaire for the glare free illumination of wall surfaces with the mounting surface being the reflection surface.
- The light emits upwards and downwards.
Product description
- Luminaire housing made of aluminium,
- finish Colour velvet white
- Synthetic cover with light diffusing structure
- Reflector made of pure anodised aluminium
- 2 elongated fixing holes
- Width 5.5mm · 1450mm spacing
- 1 cable entry for through-wiring for mains cable
- Connection terminal 2.5@
- Earth conductor connection
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 176-280 V
- During DC operation the LED power is reduced to 15%
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Impact strength IK04
- Protection against mechanical impacts < 0.5 joule
- – Safety mark
- CE– Conformity mark
- Weight: 9.3 kg
- This product contains light sources of energy efficiency class(es) D
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the
- luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp
- Module connected wattage 122 W
- Luminaire connected wattage 130 W
- Rated temperature ta=25 °C
- Ambient temperature ta max=45 °C
50 807.1K3
- Module designation 10x LED-1049/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 18300 lm
- Luminaire luminous flux 15595 lm
- Luminaire luminous efficiency 120 lm/W
Installation
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Undo the hexagon socket head screws (wrench size 3mm) and lift luminaire top.
- Loosen earth connection (plug connection) and
- LED-connection between luminaire top and luminaire base.
- Lead the mains supply cable through the cable entry of the luminaire base.
- Note position of application “arrow down”.
- Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
- Make earth conductor connection.
- Push silicone sleeves over the lines and make electrical connection.
- For digital control please use the connecting terminal DA, DA.
- In case this terminal is not used the luminaire will be operated at full light output.
- Make earth connection (plug connection) and
- LED-connection between luminaire top and luminaire base again.
- Note position of application of the luminaire “arrow down”.
- Install luminaire top part, adjust it and tighten screws evenly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Undo one of the two external locking screws (Torx) in the luminaire housing and remove the lateral housing cover. Remove the synthetic cover from the profile of the luminaire housing. Remove the LED module. Install the replacement LED module. Please follow the installation instructions for the LED module. A defective synthetic cover must be replaced. Close up the luminaire again in reverse order.
Spares
- Synthetic cover 15 000 631
- LED power supply unit DEV-0390/700i
- LED module 3000 K LED-1049/930
- Reflector short 76 001 896B1
- Reflector long 76 001 896B2
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com
References