BEGA 50651 LED Ceiling and Wall Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA 50651 LED Ceiling and Wall Luminaire

BEGA-50651-LED-Ceiling-and-Wall-Luminaire \(3\)

Product Information

The product is a luminaire that requires installation and operation according to national safety regulations. It is recommended to have a qualified electrician carry out the installation and commissioning. The manufacturer does not accept liability for damage caused by improper use or installation. Any modifications made to the luminaire should be done by a responsible person who will be considered the manufacturer.

The luminaire is equipped with electronic components that are protected against overvoltage according to DIN EN 61547. Additional overvoltage protection components are recommended for further protection against transients. These components can be found on the manufacturer’s website at www.bega.com.

The luminaire has the following specifications:

  • Lamp Module connected wattage: 16 W
  • Luminaire connected wattage: 18.5 W
  • Rated temperature: ta = 25-30°C
  • Ambient temperature: ta = max
  • Module designation: LED-0569/930
  • Colour temperature: 3000 K
  • Colour rendering index (CRI): >90
  • Module luminous flux: 2440 lm
  • Luminaire luminous flux: 1601 lm
  • Luminaire luminous efficiency: 86.5 lm/W

Product Usage Instructions

  1. Ensure that the luminaire is installed and operated according to national safety regulations.
  2. Only a qualified electrician should carry out the installation and commissioning of the luminaire.
  3. Do not use or install the luminaire improperly as it may cause damage for which the manufacturer will not be liable.
  4. If any modifications need to be made to the luminaire, they should be done by a responsible person who will be considered the manufacturer.
  5. To provide additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.
  6. When using the luminaire, ensure that the ambient temperature does not exceed the maximum rated temperature (ta = max).
  7. The luminaire has a lamp module connected wattage of 16 W and a luminaire connected wattage of 18.5 W.
  8. The colour temperature of the luminaire is 3000 K, and the colour rendering index (CRI) is greater than 90.
  9. The module luminous flux is 2440 lm, and the luminaire luminous flux is 1601 lm.
  10. The luminaire has a luminous efficiency of 86.5 lm/W.

BEGA-50651-LED-Ceiling-and-Wall-Luminaire \(1\)

Application

  • Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks.
  • They are ideal for places where a soft and uniform lighting distribution is required.

Product description

  • Metal housing, finish Colour white
  • Hand-blown opal glass, satin matt, with sliding-bolt closure
  • 2 mounting holes ø 5.5mm Distance apart 200mm 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@ Connecting terminal 2.5@ with plug connection
  • Earth conductor connection
  • LED power supply unit 220-240 V x 0/50-60 Hz DC 176-280 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies ≥ 1 mm and splash water
  • Impact strength IK05
  • Protection against mechanical impacts < 0.7 joule
  • – Safety mark c – Conformity mark
  • Weight: 2.8 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 16 W
  • Luminaire connected wattage 18.5 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=30 °C

50 651K3

  • Module designation LED-0569/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 2440 lm
  • Luminaire luminous flux * 1601 lm
  • Luminaire luminous efficiency * 86,5 lm/W
  • preliminary data

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Disassemble LED module.
  • Loosen LED-connection and earth connection (plug connection).
  • Dismantle the mains supply cable max. 80 mm.
  • Lead mains supply cable through the cable entry into the luminaire housing.
  • Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
  • It is imperative to use the enclosed gaskets.
  • Make earth and electrical connection to the terminal.
  • Make earth connection between LED module and luminaire housing (plug connection).
  • Push LED-plugs into couplers as far as it will go.
  • Assemble LED module.
  • Tighten the screws evenly (max. 0,8 Nm).
  • Please observe that the LED module is not damaged mechanically.
  • Insert the opal glass into the luminaire housing with sliding bolt glass closure and turn the glass clockwise up to the stop.
  • Place glass to the luminaire housing and observe that the holding springbolts fit into the notches of the glass.
  • Turn the glass clockwise until it is locked.
  • Thus, you reach a safe and vibration-resistant holding of the glass.
  • To release the glass from the luminaire housing, turn it counter-clockwise.

Replacement of the LED module ·

Maintenance

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Unscrew glass from luminaire housing by turning it counter-clockwise.
  • Clean glass and luminaire regularly with solvent-free cleansers from dirt.
  • Please follow the installation instructions for the
  • LED module.
  • Screw in glass by turning it clockwise as far as it will go.
  • A broken glass must be replaced.

Spares

  • Spare glass 11 002 770 .0RG
  • LED power supply unit DEV-0150/700
  • LED module 3000 K LED-0569/930

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

11 002 770 .0R G DEV-0150/700 LED-0569/930