Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection: The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against transients, etc., we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

  • Lamp Module connected wattage: 3.9 W
  • Luminaire connected wattage: 5 W
  • Rated temperature: 25°C
  • Ambient temperature: 50°C
  • Module designation: LED-1029/930
  • Colour temperature: 3000 K
  • Colour rendering index: CRI > 90
  • Module luminous flux: 525 lm
  • Luminaire luminous flux: 429 lm
  • Luminaire luminous efficiency: 85.8 lm/W
  • LED power supply unit part number: DEV-0303/350
  • LED module part number: LED-1029/930
  • Glass/Trim ring part number: 75 004 418
  • Reflector unit part number: 75 004 443

Product Usage Instructions

  1. During installation or relamping, avoid touching the light output opening of the LED directly.
  2. To ensure a secure connection, position the luminaire housing precisely in relation to the mounting plate. Make sure that the vertical bar inside the luminaire housing is positioned precisely in the area of the mounting hole on the long bar of the mounting plate. Press the luminaire housing firmly against the mounting plate and turn it clockwise firmly against the stop.
  3. Screw the enclosed trim ring with the attached reflector into the luminaire housing by turning it clockwise.
  4. To replace the LED module, disconnect the electrical installation and open the luminaire. Follow the installation instructions for the LED module. Close the luminaire after installation.

Note: The designation of the LED module is noted on a label in the luminaire. The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.

Ceiling luminaire · downlight for indoor use

Instructions for use

Application
Ceiling luminaire downlight · Indoor luminaire with symmetrical very wide beam light distribution.
BEGA Hybrid Optics® : Highly efficient and low-loss light distribution, thanks to reflector and optical lens.

Product Description

  • Ceiling luminaire downlight »GENIUS«
  • Die-cast aluminium housing,
  • Colour velvet white finish
  • Trim ring · Chrome finish
  • Clear safety glass
  • Optical silicone lens · BEGA Hybrid Optics® Reflector surface made of pure aluminium
  • 2 mounting holes ø 4.5 mm
  • Distance apart 66 mm
  • Connecting terminals 2.5@
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Impact strength IK08
  • Protection against mechanical impacts < 5 joule
  • – Conformity mark
  • Weight: 0.55 kg

This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 3.9 W
  • Luminaire connected wattage 5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C

50 927.1 K3

  • Module designation LED-1029/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 525 lm
  • Luminaire luminous flux 429 lm
  • Luminaire luminous efficiency 85,8 lm / W

Lighting technology

  • Symmetrical wide beam light distribution
  • Half beam angle 54°

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Remove mounting plate from the luminaire housing.
  • Unplug the earth conductor connection (plug contact).

Please note:

  • If the luminaire is to be mounted onto a metallic, electroconductive surface, it is mandatory to make sure that the mounting surface is connected conductive to the earth conductor of the luminaire!
  • Lead the power connecting cable through the mounting plate.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Establish the earth conductor connection on the earthing screw ( ) of the mounting plate.
  • Establish the earth conductor connection to the luminaire housing (plug contact).
  • Push silicone hoses over connecting wires and make the electrical connection at the terminal marked (L) and (N).

IMPORTANT:

  • To ensure secure connection, the luminaire housing must be positioned precisely in relation to the mounting plate.
  • Make sure that the vertical bar inside the luminaire housing is positioned precisely in the area of the mounting hole on the long bar of the mounting plate.
  • Press the luminaire housing firmly against the mounting plate and turn it clockwise firmly against the stop.

Screw enclosed trim ring with attached reflector into the luminaire housing by turning it clockwise.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the electrical installation.
  • Open the luminaire.
  • Please follow the installation instructions for the
  • LED module.
  • Close the luminaire.

Spares

  • LED power supply unit DEV-0303/350
  • LED module 3000 K LED-1029/930
  • Glass/Trim ring 75 004 418
  • Reflector unit 75 004 443

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com