BEGA 51038.5 LED Track Spotlight Instruction Manual

June 13, 2024
BEGA

BEGA 51038.5 LED Track Spotlight

BEGA 51038.5 LED Track Spotlight 

Application

Ceiling mounted track spotlight · indoor luminaire for 3-phase Eurostandard- Plus® track systems.

The optical system of the washer is swivelmounted and rotatable.

Symmetrical wide beam light distribution.

Optical filters are available as accessories for changing the light distribution.

BEGA Hybrid Optics® : Highly efficient and lowloss light distribution, thanks to reflector and optical lens.

Dimension

Dimension

Product description

GENIUS Track spotlight with adapter

Cast aluminium luminaire housing, finish Colour velvet black,

Polycarbonate track adapter with integrated

LED power supply unit

Trim ring · Chrome finish

Safety glass, with internal optical filter

Optical silicone lens · BEGA Hybrid Optics®

Reflector surface made of pure aluminium

LED power supply unit 220-240 V ∼ 50/60 Hz

DALI-controllable

Number of DALI addresses: 1

Basic insulation is provided between the mains and control cables

Safety class II

 – Conformity mark

Weight: 0.65 kg

This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations.

Installation and commissioning may only be carried out by a qualified electrician.

The manufacturer accepts no liability for damage caused by improper use or installation.

If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.

To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.

You can find them on our website at www.bega.com.

Lamp

Module connected wattage 12.3 W
Luminaire connected wattage 14.5 W
Rated temperature ta=25 °C
Ambient temperature ta max=55 °C

51 038.5K3

Module designation LED-0986/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 1685 lm
Luminaire luminous flux 1220 lm
Luminaire luminous efficiency 84,1 lm/W

51 038.5K4

Module designation LED-0986/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 1710 lm
Luminaire luminous flux 1238 lm
Luminaire luminous efficiency 85,4 lm/W

Light technique

Track spot · surface washer with adjustable optical system.

Optical system 0-340° swivel-mounted and ± 310° infinitely rotatable around the vertical luminaire axis.

Symmetrical wide beam light distribution. Half beam angle 55°

The symmetrical light cone can be changed to a flat beam, symmetrically diffuse or asymmetrical light distribution for special lighting applications by replacing the optical filter (standard) –  accessories.

For flat beam light distribution:

Optical filter 13 287
For symmetrically diffuse light distribution:
Optical filter 13 310
For asymmetrical light distribution:
Optical filter 13 309
Light technique
Light technique

The light cone can be adjusted by ±360° by turning the trim ring.

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

The track spotlight with adapter is ready for operation in 3-phase EUROSTANDARD-PLUS® track systems.

The mounting is done without tools in the bus bar.

IMPORTANT:

Ensure that the adapter’s two lateral stays are located on the same side as the matching guide profile of the track before installing the adapter in the 3-phase EUROSTANDARDPLUS® track system.

To select the phase ( 1 2 3 ) the turning knob on the rear side of the adapter has to be operated accordingly

Screw enclosed fastening ring (a) with attached reflector into the luminaire housing by turning it clockwise until it stops, so that it is fixed by clamping.
Installation

Clip the enclosed trim ring with glass and internal optical filter (b) onto the luminaire housing by applying slight pressure.
Installation

Place the surface washer adapter flush on the conductor rail in the desired position.

Push the two fixing levers on the underside of the adapter to the right until they click into their end position.

Set the desired LED beam direction by turning and tilting the luminaire housing.

Move the two fixing levers in opposite directions until they disengage to unlock the adapter.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.

The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.

Disconnect the system and open the luminaire. Uninstall the reflector.

Please follow the installation instructions for the LED module.

Install the reflector. Defective glass must be replaced. Close the luminaire.

Accessories · Optical filters

13 287 Optical filter flat beam
13 310 Optical filter symmetrical, diffuse
13 309 Optical filter asymmetrical

For the accessories a separate instructions for use can be provided upon request.

Spares

Prismatic film 15 000 683
Fastening ring reflector 20 000 106B6
LED power supply unit DEV-0438/350i
LED module 3000 K LED-0986/930
LED module 4000 K LED-0986/940
Reflector unit 75 004 443
Trim ring with glass 75 004 843

Customer Support

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals