Recessed ceiling downlight for indoor use
Instruction Manual
50 695.1 Recessed Ceiling Downlight for Indoor Use
Instructions for use
Application
Recessed ceiling downlight · Interior luminaire with symmetrical narrow beam
light distribution for connection to an external LED power supply unit.
For surface-mounted installation in indoor suspended ceilings of 8-25 mm
thickness.
Product description
Recessed luminaire without power supply unit Luminaire housing made of cast
aluminium Installation housing is made of glass-fibre reinforced polyamide
with 2 fastening springs
Reflector made of pure anodised aluminium
Optical silicone lens
Ceiling trim ring made of metal, Colour white
Partially matt crystal glass
Recessed opening ø 188 mm
Required installation depth 125 mm 1 connecting cable with strain relief and
plug connector system for BEGA power supply unit, on/off or DALI
Safety class III
– Conformity mark
Weight: 2.4 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 17.2 W |
---|---|
Luminaire connected wattage | 19.8 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 40 °C |
50 695.1 K3
Module designation | LED-0785/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 2655 lm |
Luminaire luminous flux | 1724 lm |
Luminaire luminous efficiency | 87,1 lm / W |
Lighting technology
Half beam angle 50°
Installation
Luminaire housing must not be installed in heat-insulating material.
A separate power supply unit is required to operate the luminaire.
For connection to external LED-power supply unit – accessory 13 144 or 13 170
– the luminaire is equipped with a 2-pin connector.
Note operating instructions of the LED-power supply units.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the installation housing in the recessed opening is achieved by
using two adjustable springs.
Installation into inserted ceilings:
A recessed opening of 188 mm is necessary to accept the installation housing.
Recessed depth min. 125 mm.
The lateral distance between recessed luminaire and other building parts must
be at least 50 mm.
Compress the fastening springs of the installation housing against their
spring pressure on both sides towards the housing and slide the installation
housing into the recessed opening.
The fastening springs catch the ceiling panel from the back side. Minimum
thickness of the ceiling panel is 8 mm. If minimum thickness of the panel is
less than 3 mm it must be reinforced from the reverse side. Maximum thickness
of the ceiling panel must be no more than 25 mm.Push the enclosed threaded rods through the two inside openings
of the installation housing and guide the clamping angle of the threaded rods
downwards onto the suspended ceiling. Clip the threaded rods into their guide
grooves and screw them in by hand as far as possible. Fix in end position with
screwdriver (TX 10). This clamp fixing prevents the installation housing from
turning and dropping.
Connect to the LED power supply unit. Route the LED power supply unit through
the installation housing and place it in the suspended ceiling.
Connect the 2-pin plug connector between luminaire and external LED power
supply unit.Press together the two internal
fixing sliders inside the luminaire housing.
Push the luminaire housing to the end of the installation housing and then
release the fixing sliders.
This mechanism ensures that the luminaire housing sits securely inside the
installation housing.
Installation housing and external LEDpower supply unit must not be installed
in heat-insulating material.
Please use the protective gloves provided for the installation to prevent
finger prints on the reflector.
Place the reflector with silicone lens onto the glass.
Twist the glass with the attached reflector to the right to fix the assembly
inside the luminaire housing.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Close the luminaire.
Accessories
Power supply units for LED luminaires
220-240 V · 0/50-60 Hz with strain relief and plug connector system.
13 144 Power supply unit on/off
13 170 Power supply unit DALI
The power supply units are only suitable for the operation of one LED
luminaire.
For the accessories a separate instructions for use can be provided upon
request.
Spares
Spare glass | 003 451 10M 1RG |
---|---|
LED module 3000 K | LED-0785/930 |
Reflector | 75 002 753 |
Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com