BEGA 89 017 Ceiling and Wall Luminaire for Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
89 017
Technical amendments reserved
Instructions for use
89 017 Ceiling and Wall Luminaire for Indoor
Ceiling and wall luminaire for indoor use
Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass,
satin matt and metal housing, for all lighting tasks.
They are ideal for places where a soft and uniform lighting distribution is
required.
Luminaire with a high protection class.
Lamp
Luminaire with screw base E 27
Lamp output max. 75 W
This product contains light sources of energy
efficiency class E
Supplied lamp
BEGA LED lamp 13548
LED Retrofit 7 W · 805 lm · 2700 K dimmable
Supplied lamp
BEGA LED lamp 13586
LED Retrofit 7 W · 805 lm · 3000 K dimmable
Luminaire efficiency: 69%
Detailed technical and lighting data for the lamps can be found in the data
sheets on our website.
Product description
Aluminium alloy housing, finish Colour white Hand-blown opal glass, satin matt
2 mounting holes ø 6 mm Distance apart 110 mm 2 cable entries for through-
wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@
Lampholder terminals 2.5@ Earth conductor terminal Lampholder E 27
Safety class I Protection class IP 44 Protected against granular foreign
bodies ≥ 1 mm and splash water Impact strength IK02
Protection against mechanical impacts < 0.2 joule
– Safety mark
– Conformity mark
Weight: 1.6 kg
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
Instalxlation
Lead the mains supply cable through the cable entry of the luminaire base. For
wall installation note the position of application “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied.
Establish earth conductor connection and make the electrical connection to the
terminals.
Insert lamp.
Snap the opal glass into the lower spring clips, centralise and push into the
upper spring clips.
Relamping · Maintenance
Disconnect the electrical installation.
Take off glass from housing.
Clean luminaire and glass.
Use only solvent-free cleansers.
Change the lamp.
Insert glass into housing.
Spares
Spare glass | 11 002 057 .0R G |
---|---|
LED lamp 2700 K | 13 548 |
LED lamp 3000 K | 13 586 |
Lampholder | 63 000 052 |
89 017 BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 ·
58689 Menden ·
info@bega.com ·
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>