Product Information
- Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning should be done by a qualified electrician. The manufacturer is not liable for damage caused by improper use or installation.
- Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage according to DIN EN 61547. Additional overvoltage protection components are recommended for extra protection against transients.
- Lamp: The connected wattage for the lamp module is 8.5 W and for the luminaire is 10.4 W.
- Rated Temperature: The rated temperature for the luminaire is between 25°C and 35°C.
- Ambient Temperature: The ambient temperature for the luminaire should not exceed the maximum temperature specified.
- Luminaire Specifications:
- Module Designation: LED-0923/927
- Colour Temperature: 2700 K
- Colour Rendering Index (CRI): > 90
- Module Luminous Flux: 1155 lm
- Luminaire Luminous Flux: 581 lm
- Luminaire Luminous Efficiency: 55.9 lm/W
- Module Designation: LED-0923/930
- Colour Temperature: 3000 K
- Colour Rendering Index (CRI): > 90
- Module Luminous Flux: 1200 lm
- Luminaire Luminous Flux: 604 lm
- Luminaire Luminous Efficiency: 58.1 lm/W
- Spares:
- Spare Glass: 11 003 006 410 RG
- LED Power Supply Unit: DEV-0279/250
- LED Module 2700 K: LED-0923/927
- LED Module 3000 K: LED-0923/930
- Trim Ring: 72 009 562 L
- Reflector: 76 001 209
Product Usage Instructions
- The installation and commissioning of the luminaire should be done by a qualified electrician following national safety regulations.
- Avoid touching the light output opening of the LED directly during installation or relamping. The recessed opening will be covered by the frame of the luminaire.
- The luminaire should not be installed in heat-insulating material.
- The luminaire can be fixed using 2 adjustable wedge-shaped claws.
Dimension
Recessed ceiling luminaire for indoor use
Application
- Recessed ceiling luminaire · indoor luminaire partially satin matt crystal glass inside and aluminium alloy housing.
- For installation into ceilings with a shallow depth in interior areas.
Product description
- Recessed ceiling luminaire »ACCENTA« Die-cast aluminium housing
- Crystal glass, partially satin matt inside
- Reflector made of pure, high-gloss anodized aluminium
- Ceiling frame ring made of stainless steel Recessed opening ø 68 mm
- Required installation depth 60 mm
- Fixing is achieved by using 2 adjustable wedge-shaped claws
- External LED power supply unit
- 220-240 V x 0/50-60 Hz
- Safety class II
- – Safety mark
- – Conformity mark
- Weight: 0.22 kg
- This product contains light sources of energy efficiency class(es) E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp
-
Module connected wattage 8.5 W
-
Luminaire connected wattage 10.4 W
-
Rated temperature ta = 25 °C
-
Ambient temperature ta max = 35 °C
50 710.2 K27 -
Module designation LED-0923/927
-
Colour temperature 2700 K
-
Colour rendering index CRI > 90
-
Module luminous flux 1155 lm
-
Luminaire luminous flux 581 lm
-
Luminaire luminous efficiency 55,9 lm / W
50 710.2 K3 -
Module designation LED-0923/930
-
Colour temperature 3000 K
-
Colour rendering index CRI > 90
-
Module luminous flux 1200 lm
-
Luminaire luminous flux 604 lm
-
Luminaire luminous efficiency 58,1 lm / W
Installation
- Luminaire housing must not be installed in heat-insulating material.
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- The recessed opening will be covered by the frame of the luminaire.
- Fixing of the luminaire is achieved by using 2 adjustable wedge-shaped claws.
Installation into false ceilings
- A recessed opening of ø 68 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm (see sketch).
- The claws catch the panel from the reverse side. If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side. Maximum thickness of the panel must be no more than 20 mm.
- Remove cover of the external LED-power supply unit.
- Loosen set screws of cable strain relief.
- Tightening zone for strain relief: max. Ø 12mm.
- Connecting terminals for mains supply: max. 2,5@.
- Strip the wires 6 mm.
- Lead mains supply cable through the cable strain relief and fix set screws.
- Make electrical connection.
- Close case cover of the external LED-power supply unit and press it until it is locked.
- Push external LED-power supply unit and luminaire housing into ceiling cut-out.
- Luminaire housing and external LEDpower supply unit must not be installed in heat-insulating material.
- Hand-tight screws of claw fasteners evenly.
- Lead enclosed ceiling frame ring over the screw-neck of the glass and push it down the gasket.
- Make sure that gasket is positioned correctly.
- Insert glass with mounted reflector and frame ring by turning it clockwise into luminaire housing.
Cleaning · Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt.
- Defective glass must be replaced.
Replacement of the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect from main supply.
- Unscrew glass with ceiling frame ring from luminaire housing by turning it counterclockwise.
- Please follow the installation instructions for the LED module.
- Check gasket. Screw in glass with ceiling frame ring by turning it clockwise beyond the stop.
- Defective glass must be replaced.
Spares
- Spare glass 11 003 006 410 RG
- LED power supply unit DEV-0279/250
- LED module 2700 K LED-0923/927
- LED module 3000 K LED-0923/930
- Trim ring 72 009 562 L
- Reflector 76 001 209
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>