BEGA 50 710.2 Ceiling Light LED Instruction Manual

June 13, 2024
BEGA

BEGA 50 710.2 Ceiling Light LED

Product Information

  • Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning should be done by a qualified electrician. The manufacturer is not liable for damage caused by improper use or installation.
  • Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage according to DIN EN 61547. Additional overvoltage protection components are recommended for extra protection against transients.
  • Lamp: The connected wattage for the lamp module is 8.5 W and for the luminaire is 10.4 W.
  • Rated Temperature: The rated temperature for the luminaire is between 25°C and 35°C.
  • Ambient Temperature: The ambient temperature for the luminaire should not exceed the maximum temperature specified.
  • Luminaire Specifications:
    • Module Designation: LED-0923/927
    • Colour Temperature: 2700 K
    • Colour Rendering Index (CRI): > 90
    • Module Luminous Flux: 1155 lm
    • Luminaire Luminous Flux: 581 lm
    • Luminaire Luminous Efficiency: 55.9 lm/W
  • Module Designation: LED-0923/930
  • Colour Temperature: 3000 K
  • Colour Rendering Index (CRI): > 90
  • Module Luminous Flux: 1200 lm
  • Luminaire Luminous Flux: 604 lm
  • Luminaire Luminous Efficiency: 58.1 lm/W
  • Spares:
    • Spare Glass: 11 003 006 410 RG
    • LED Power Supply Unit: DEV-0279/250
    • LED Module 2700 K: LED-0923/927
    • LED Module 3000 K: LED-0923/930
    • Trim Ring: 72 009 562 L
    • Reflector: 76 001 209

Product Usage Instructions

  1. The installation and commissioning of the luminaire should be done by a qualified electrician following national safety regulations.
  2. Avoid touching the light output opening of the LED directly during installation or relamping. The recessed opening will be covered by the frame of the luminaire.
  3. The luminaire should not be installed in heat-insulating material.
  4. The luminaire can be fixed using 2 adjustable wedge-shaped claws.

Dimension

Recessed ceiling luminaire for indoor useBEGA-50-710-2-Ceiling-Light-LED-fig
1

Application

  • Recessed ceiling luminaire · indoor luminaire partially satin matt crystal glass inside and aluminium alloy housing.
  • For installation into ceilings with a shallow depth in interior areas.

Product description

  • Recessed ceiling luminaire »ACCENTA« Die-cast aluminium housing
  • Crystal glass, partially satin matt inside
  • Reflector made of pure, high-gloss anodized aluminium
  • Ceiling frame ring made of stainless steel Recessed opening ø 68 mm
  • Required installation depth 60 mm
  • Fixing is achieved by using 2 adjustable wedge-shaped claws
  • External LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • Safety class II
  • – Safety mark
  • – Conformity mark
  • Weight: 0.22 kg
  • This product contains light sources of energy efficiency class(es) E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 8.5 W

  • Luminaire connected wattage 10.4 W

  • Rated temperature ta = 25 °C

  • Ambient temperature ta max = 35 °C
    50 710.2 K27

  • Module designation LED-0923/927

  • Colour temperature 2700 K

  • Colour rendering index CRI > 90

  • Module luminous flux 1155 lm

  • Luminaire luminous flux 581 lm

  • Luminaire luminous efficiency 55,9 lm / W
    50 710.2 K3

  • Module designation LED-0923/930

  • Colour temperature 3000 K

  • Colour rendering index CRI > 90

  • Module luminous flux 1200 lm

  • Luminaire luminous flux 604 lm

  • Luminaire luminous efficiency 58,1 lm / W

Installation

  • Luminaire housing must not be installed in heat-insulating material.
  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • The recessed opening will be covered by the frame of the luminaire.
  • Fixing of the luminaire is achieved by using 2 adjustable wedge-shaped claws.

Installation into false ceilings

  • A recessed opening of ø 68 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm (see sketch).
  • The claws catch the panel from the reverse side. If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side. Maximum thickness of the panel must be no more than 20 mm.
  • Remove cover of the external LED-power supply unit.
  • Loosen set screws of cable strain relief.
  • Tightening zone for strain relief: max. Ø 12mm.
  • Connecting terminals for mains supply: max. 2,5@.
  • Strip the wires 6 mm.
  • Lead mains supply cable through the cable strain relief and fix set screws.
  • Make electrical connection.
  • Close case cover of the external LED-power supply unit and press it until it is locked.
  • Push external LED-power supply unit and luminaire housing into ceiling cut-out.
  • Luminaire housing and external LEDpower supply unit must not be installed in heat-insulating material.
  • Hand-tight screws of claw fasteners evenly.
  • Lead enclosed ceiling frame ring over the screw-neck of the glass and push it down the gasket.
  • Make sure that gasket is positioned correctly.
  • Insert glass with mounted reflector and frame ring by turning it clockwise into luminaire housing.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.
  • Defective glass must be replaced.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect from main supply.
  • Unscrew glass with ceiling frame ring from luminaire housing by turning it counterclockwise.
  • Please follow the installation instructions for the LED module.
  • Check gasket. Screw in glass with ceiling frame ring by turning it clockwise beyond the stop.
  • Defective glass must be replaced.

Spares

  • Spare glass 11 003 006 410 RG
  • LED power supply unit DEV-0279/250
  • LED module 2700 K LED-0923/927
  • LED module 3000 K LED-0923/930
  • Trim ring 72 009 562 L
  • Reflector 76 001 209

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com