BEGA 24 314 Ceiling Mounted Downlight Instruction Manual

June 13, 2024
BEGA

BEGA 24 314 Ceiling Mounted Downlight

DIMENSION

BEGA-24-314-Ceiling-Mounted-Downlight-FIG-1

Instructions for use

Application
Ceiling-mounted downlight with symmetrical wide beam light distribution. Bands of light of different lengths can be created by installing single luminaires in rows. A luminaire for linear illumination both indoors and out.

Product description
Luminaire made of aluminum alloy, aluminum and stainless steel BEGA Unidure® coating technology Colour graphite  Matt safety glass Silicone gasket BEGA Vortex Optics® . Reflector surface made of pure aluminium Mounting bar with 2 elongated holes 7 mm width, 1100 mm spacing 2 screw cable glands with strain relief for through-wiring of the mains supply cablefrom ø 7,5–10,8 mm, max. 5 G 1,5@ 1 screw cable gland closed at the factory with a dummy plug Connecting terminal 2.5@ with plug connection Earth conductor connection LED power supply unit 220-240 V x 0/50-60 Hz DC 176-276 V During DC operation the LED power is reduced to 15 % DALI-controllable Basic insulation is provided between the mains and control cables BEGA Thermal Control® Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I p Ballproof according to DIN VDE 0710 part 13 Protection class IP 65 Dust-tight and protection against water jets Impact strength IK07 Protection against mechanical impacts < 2 joule r – Safety mark c  – Conformity mark Weight: 9.2 kg
This product contains light sources of energy efficiency class(es) C

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp0

  • Module connected wattage 47.4 W
  • Luminaire connected wattage 54.4 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C

24 314 K3

  • Module designation 6x LED-0771/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 8850 lm
  • Luminaire luminous flux 6955 lm
  • Luminaire luminous efficiency 127,8 lm / W

24 314 K4

  • Module designation 6x LED-0771/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 9090 lm
  • Luminaire luminous flux 7175 lm
  • Luminaire luminous efficiency 131,9 lm / W

Lighting technology
Half beam angle 55°

Installation

Undo hexagon socket screws (wrench size 3) and lift mounting bar out of the luminaire housing. Lead mains supply cable through the opening of the mounting bar. Fix mounting bar with enclosed or other suitable fixing material onto mounting surface. It is absolutely essential to have an even mounting surface. Undo hexagon socket screws and remove connecting compartment cover from the luminaire housing.BEGA-24-314-Ceiling-Mounted-Downlight-
FIG-2

Lead mains supply cable through the cable entry of the connecting compartment cover. In case of through-wring remove the factory installed dummy plug. Tighten screw cable gland. Make earth conductor connection and electrical connection to the connecting terminal (plug connection). For digital control please use the connecting terminal DA, DA. In case this terminal is not used the luminaire will be operated at full light output. In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Push plug into coupler as far as it will go. Assemble connecting compartment cover. Make sure that the gasket is positioned correctly. Hang the luminaire housing in the mounting rail and screw it in place.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets. Defective glass must be replaced. Close the luminaire.

Spares

  • Housing + Glass graphite 25 000 029
  • Housing + Glass Colour of choice 25 000 217
  • LED power supply unit DEV-0214/1050i
  • LED module 3000 K LED-0771/830
  • LED module 4000 K LED-0771/840
  • Reflector 76 001 591
  • Gasket connecting compartment cover 83 001 866
  • Gasket housing 83 002 131

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com