BEGA 84399K3 Underwater Floodlight Instruction Manual

June 13, 2024
BEGA

Technical amendments reserved

84399K3 Underwater Floodlight

Underwater floodlight

Instructions for use

Application
Water pressure tight underwater floodlight with very shallow construction form for the illumination of ponds, water pools and water features up to a depth of 20 m.
The floodlight must only be operated under water and must be protected against freezing in.
To avoid damages on the surface of the floodlight, the water must have a neutral pH-value and should be free from metal attacking ingredients.

Lamp

Module connected wattage 49.7 W
Luminaire connected wattage 62 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 60 °C
Voltage 24 V = DC

84 399 K3

Module designation LED-1199/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 8200 lm
Luminaire luminous flux * 4063 lm
Luminaire luminous efficiency * 65,5 lm / W
  • preliminary data

Product description

Luminaire made stainless steel Steel grade no. 1.4301 – electropolished Clear safety glass Reflector made of pure anodised aluminium Swivel range 90° Mounting bracket with 2 holes ø 7 mm · 45 mm spacing water-resistant connecting cable 05RN8-F 2 × 1@
Cable length 4 m Safety class III Protection class IP 68 20 m Dust-tight and water pressure tight Maximum submersion depth 20 m Impact strength IK09 Protection against mechanical impacts < 10 joule ****– Conformity mark Weight: 2.2 kg This product contains light sources of energy efficiency class(es) D

Light technique

Luminaire data for the light planning program DIALux for outdoor lighting, street lighting and indoor lighting as well as luminaire data in EULUMDAT and IES-format you will find on the BEGA web page www.bega.com. The details apply to free burning floodlights. The lighting intensity is depending on the submerged depth of the floodlight and on the purity of the water.

Safety

The installation and operation of this luminaire are subject to national safety regulations. nstallation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Please note:
The luminaire can only be operated with an operating device that fulfills the requirements according to EN 61347-2-13.
The maximum idle voltage of 30 V DC must conform to SELV or SELV equivalent – see accessories.

Installation

The floodlight must only be operated under water.
Minimum installation depth of floodlight 3 cm below water level.
Undo hexagon nuts and remove floodlight housing from the slotted fixing bracket.
Fix mounting bracket on the mounting surface using delivered stainless steel screws.
Insert the floodlight housing into the slotted fixing bracket, align and fix it.
Tighten hexagon nuts firmly and evenly.
Torque = 5 Nm.
A 24 V safety direct voltage source with a smoothed residual ripple of max. 10 % is required for the electrical connection of the luminaire – see accessories.
If other safety direct voltage sources are used, an upstream fuse (max. 6 A) must be provided by the customer.
Make sure that the poles are connected correctly. (otherwise destruction of the DC-converter)
Connect black conductor with negative pole and red conductor with positive pole of the power supply unit.

Cleaning · Maintenance

Soilings and foulings on the stainless steel parts should be removed frequently. They can be removed with suitable stainless steel cleansers. For cleaning do not use high pressure cleaners.

Replacement of the LED module Maintenance

Disconnect the electrical installation.
Undo hexagon nuts, remove floodlight housing from the slotted fixing bracket and lift floodflight above water level.
Open the floodlight: Undo counter sunk screws.
Lift cover ring and glass with gaskets.
Remove reflector.
Disassemble LED module.
Clean the luminaire (see Cleaning · Maintenance).
It is imperative to replace damaged gaskets and cable.
The lamp compartment must be completely clean and absolutely dry.
Assemble LED replacement module.
Note installation instructions of the LED module.
Insert reflector.
Place the glass between the gaskets and into the housing.
Make sure that gasket is positioned correctlyApply cover ring and firmly tighten countersunk-head screw crosswise.
Torque = 3 Nm.
Insert the floodlight housing into the slotted fixing bracket, align and fix it.
Tighten hexagon nuts firmly and evenly.
Torque = 5 Nm.
Only correctly positioned gaskets and tight screw cable glands guarantee a watertight housing.

Accessories

BEGA Safety transformers according to
EN 61558-2-6/VDE 0570, part 2-6
70 567 Power supply unit for 40 – 75 W
70 169 Power supply unit for 70 – 150 W
For the accessories a separate instructions for use can be provided upon request.

Spares

Spare glass 14 000 045
LED module 3000 K LED-1199/830
Reflector 76 001 230
Gasket 83 001 808

BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 ·
58689 Menden ·
info@bega.com ·
www.bega.com

Documents / Resources

| BEGA 84399K3 Underwater Floodlight [pdf] Instruction Manual
84399K3 Underwater Floodlight, 84399K3, Underwater Floodlight, Floodlight
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals