BEGA 67 684.3 Wall Luminaire for Indoor Use Instruction Manual

June 12, 2024
BEGA

BEGA 67 684.3 Wall Luminaire for Indoor Use Instruction Manual
Wall Luminaire for Indoor Use

Instructions for use

Dimensions

Application
Wall luminaire · indoor luminaire made of handblown opal glass, satin matt and metal housing. For all lighting tasks in interior applications. Luminaire with a high protection class.

Product description

  • Die-cast aluminium and aluminium housing, finish Chrome
  • Hand-blown opal glass, satin matt
  • Silicone gasket 2 mounting holes ø 5.5mm Distance apart 540 x 56mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5mm, max. 5G1.5@ Connection terminal 2.5@ Earth conductor connection 2-pole connecting terminal for digital control
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies ≥ 1 mm and splash water
  • Impact strength IK02
  • Protection against mechanical impacts < 0.2 joule
  •  Safety mark
  •  Conformity mark
  • Weight: 2.8 kg
  • This product contains light sources of energy efficiency classes D

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp
Module connected wattage 16.6 W
Luminaire connected wattage 19.5 W
Rated temperature ta=25 °C
Ambient temperature ta max=45 °C

67 684.3K27
Module designation 2x LED-0546/927 2x LED-0551/927
Colour temperature 2700 K
Colour rendering index CRI >90
Module luminous flux 2470 lm
Luminaire luminous flux 1649 lm
Luminaire luminous efficiency 84,6 lm/W

67 684.3K3
Module designation 2x LED-0546/927 2x LED-0551/927
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 2530 lm
Luminaire luminous flux 1703 lm
Luminaire luminous efficiency 87,3 lm/W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping. Loosen screw of the lateral cover and take off the glass from the luminaire housing. Lead the mains supply cable through the cable entry into the luminaire housing. Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface. It is absolutely essential to use the enclosed gaskets. Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection. For digital control please use the connecting terminal DA, DA. In case this terminal is not used the luminaire will be operated at full light output. Position glass into the base plate and fix it with the screw and the cover.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective glass must be replaced.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the
  • LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares
Spare glass 11 002 830 .0RG
LED power supply unit DEV-0388/370
LED module 2700 K LED-0551/927
LED module 3000 K LED-0551/930
LED module 2700 K LED-0546/927
LED module 3000 K LED-0546/930
Gasket glass 81 000 277 .3
Gasket 83 001 249

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden ·
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals