Application

Surface mounted downlight with symmetrical light distribution.
The partially frosted crystal glass produces an additional vertical light and supplements the light directed downwards by multi-facetted light graphics.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure® coating technology Crystal glass with thread, partially frosted Silicone gasket
Reflector made of pure anodised aluminium 2 mounting holes ø 4.5 mm Distance apart 180 mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@ Connecting terminal and earth conductor terminal 2.5@ LED power supply unit 220-240 V x 0/50-60 Hz DC 170-276 V DALI-controllable
Basic insulation is provided between the mains and control cables BEGA Thermal Switch ®
Temporary thermal shutdown to protect temperature-sensitive components Safety class I Protection class IP 65 Dust-tight and protection against water jets Impact strength IK06 Protection against mechanical impacts < 1 joule r
Safety mark c
**** Conformity mark
Weight: 4.2 kg This product contains light sources of energy efficiency classes D

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

Module connected wattage 35.7 W
Luminaire connected wattage 39.3 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 40 °C

66 058 K3

Module designation LED-0785/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 6010 lm
Luminaire luminous flux 3278 lm
Luminaire luminous efficiency 83,4 lm / W

66 058 K4

Module designation LED-0785/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 6165 lm
Luminaire luminous flux 3363 lm
Luminaire luminous efficiency 85,6 lm / W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Screw out glass from the base.
Lead the mains supply cable through the cable entry into the luminaire housing. Fasten the luminaire housing with the supplied fastening material or other suitable fastening material to the mounting surface.
Be sure to use the gasket rings supplied.
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
Make the earth conductor connection and the electrical connection. For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire  will be operated at full light output. Make sure that gasket is positioned correctly. Screw the glass into the luminaire housing against the gasket.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Die Bezeichnung des LED-Moduls ist auf einem Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets. Defective glass must be replaced. Close the luminaire.

Spares

Spare glass 11 003 120 10
LED power supply unit DEV-0391/700
LED module 3000 K LED-0785/830
LED module 4000 K LED-0785/840
Reflector 76 001 369 M
Gasket 83 001 466

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com

Documents / Resources

| BEGA 66 058 Ceiling Mounted Downlight [pdf] Instruction Manual
66 058 Ceiling Mounted Downlight, 66 058, Ceiling Mounted Downlight, Mounted Downlight, Downlight
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals