BEGA 50 167.1 Ceiling Mounted Downlight for Indoor Use Instruction Manual

June 12, 2024
BEGA

BEGA 50 167.1 Ceiling Mounted Downlight for Indoor Use

Product Information

  • Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
  • Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against transients, etc., it is recommended to use separate overvoltage protection components. These components can be found on our website at  www.bega.com.
  • Lamp :
    • Module connected wattage: 8.2 W
    • Luminaire connected wattage: 9.5 W
    • Rated temperature: 25°C
    • Ambient temperature: 40°C
  • Module K3:
    • Module designation: LED-0588/930
    • Colour temperature: 3000 K
    • Colour rendering index (CRI): >90
    • Module luminous flux: 1205 lm
    • Luminaire luminous flux: 853 lm
    • Luminaire luminous efficiency: 89.8 lm/W
  • Module K4:
    • Module designation: LED-0588/940
    • Colour temperature: 4000 K
    • Colour rendering index (CRI): >90
    • Module luminous flux: 1255 lm
    • Luminaire luminous flux: 888 lm
    • Luminaire luminous efficiency: 93.5 lm/W
  • Spares:
    • LED power supply unit: DEV-0304/350
    • LED module 3000 K: LED-0588/930
    • LED module 4000 K: LED-0588/940
    • Reflector: 76 001 428
    • Gasket: 83 001 570

Instructions for use

BEGA-50167-1-Ceiling-Mounted-Downlight-for-Indoor-
Use-1

Application
Compact downlight · indoor luminaire with symmetrical wide beam light distribution.

Product description

  • Die-cast aluminium and aluminium housing, finish Colour white
  • Safety glass with optical structure Silicone gasket
  • Reflector surface made of pure aluminium
  • 2 mounting holes ø 4.8mm
  • Distance apart 70mm
  • 1 cable entry for mains supply cable up to ø 10,5mm
  • Connection terminal 2.5@
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK06
  • Protection against mechanical
  • impacts < 1 joule
    • Weight: 0.85 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 8.2 W
  • Luminaire connected wattage 9.5 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=40 °C

50 167.1K3

  • Module designation LED-0588/930
  • Colour temperature 3000 K
  • Colour rendering index CRI >90
  • Module luminous flux 1205 lm
  • Luminaire luminous flux 853 lm
  • Luminaire luminous efficiency 89,8 lm/W

50 167.1K4

  • Module designation LED-0588/940
  • Colour temperature 4000 K
  • Colour rendering index CRI >90
  • Module luminous flux 1255 lm
  • Luminaire luminous flux 888 lm
  • Luminaire luminous efficiency 93,5 lm/W

Lighting technology: Half beam angle 38°

Installation

  • Undo the screws and lift off the luminaire top. LED are high-quality electronic components!

  • Please avoid touching the light output opening of the LED directly during installation or relamping.

  • Lead the mains supply cable through the cable entry into the luminaire back housing.

  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.

  • Be sure to use the gasket rings supplied.

  • Make earth conductor connection.

  • Push silicone sleeves over the lines and make electrical connection.
    Make earth conductor connection between luminaire top and luminaire base.

  • Push plug into coupler as far as it will go.

  • Install the luminaire top, press-on and tighten screws evenly.

Cleaning and Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • LED power supply unit DEV-0304/350
  • LED module 3000 K LED-0588/930
  • LED module 4000 K LED-0588/940
  • Reflector 76 001 428
  • Gasket 83 001 570

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · [email protected] · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals