BEGA 12 163 Ceiling and Wall Luminaire for Indoor Use
Product Information
The product is a luminaire that requires installation and operation in
accordance with national safety regulations. It should only be installed and
commissioned by a qualified electrician. The manufacturer does not accept
liability for damage caused by improper use or installation. The luminaire is
equipped with electronic components that are protected against overvoltage in
accordance with DIN EN 61547. Additional overvoltage protectioncomponents are
recommended for further protection. The product has a lamp module connected
wattage of 24.5 W and a luminaire connected
wattage of 28.7 W. The rated temperature is 25°C and the ambient temperature
should not exceed 35°C. The luminaire uses LED-0530/930 modules with a color
temperature of 3000 K, a color rendering index (CRI) greater than 90, a module
luminous flux of 3625 lm, a luminaire luminous flux of 2437 lm, and a
luminaire luminous efficiency of 84.9 lm/W.
Product Usage Instructions
- To install the luminaire, place the glass to the luminairehousing.
- Ensure that the holding springbolts fit into the notches of theglass.
- Turn the glass clockwise until it is locked for a safe and vibration-resistant hold.
- To release the glass from the luminaire housing, turn it counter-clockwise.
For spare parts, the product includes a spare glass, LED power supply unit, LED module 3000 K, and grommet. The corresponding part numbers are as follows: Spare glass – 11 002 941 .1R G, LED power supply unit – DEV-0365/700, LED module 3000 K – LED-0530/930, and grommet – 83 001 391.
Dimension
Ceiling and wall luminaire for indoor use
Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.
Product description
- Metal housing, finish Colour white
- Hand-blown opal glass, with sliding-bolt closure
- 2 mounting holes ø 5.5 mm
- Distance apart 150 mm
- 1 cable entry for through-wiring
- for mains cable
- Connecting terminal 2.5@
- with plug connection
- Earth conductor connection
- 2-pole connecting terminal for
- digital control
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 170-280 V
- DALI-controllable
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Impact strength IK04
- Protection against mechanical
- impacts < 0.5 joule
- – Safety mark
- – Conformity mark
- Weight: 5.1 kg
- This product contains light sources of energy efficiency class(es) D
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only becarried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp
-
Module connected wattage 24.5 W
-
Luminaire connected wattage 28.7 W
-
Rated temperature ta = 25 °C
-
Ambient temperature ta max = 35 °C
12 163 K3 -
Module designation LED-0530/930
-
Colour temperature 3000 K
-
Colour rendering index CRI > 90
-
Module luminous flux 3625 lm
-
Luminaire luminous flux 2437 lm
-
Luminaire luminous efficiency 84,9 lm / W
Installation
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Disassemble LED module.
- Loosen LED-connection and earth connection (plug connection).
- Dismantle the mains supply cable max. 80 mm.
- Lead mains supply cable through the cable entry into the luminaire housing.
- Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
- It is imperative to use the enclosed gaskets.
- Make earth and electrical connection to the terminal.
- For digital control please use the connecting terminal DA, DA.
- In case this terminal is not used the luminaire will be operated at full light output.
- Make earth connection between LED module and luminaire housing (plug connection).
- Push LED-plugs into couplers as far as it will go.
- Assemble LED module.
- Tighten the screws evenly (max. 0,8 Nm).
- Please observe that the LED module is not damaged mechanically.
ATTENTION!
- It is mandatory to make sure not to damage the wires while fixing the opal glass.
- Insert the opal glass into the luminaire housing with sliding bolt glass closure and turn the glass clockwise up to the stop.
- Place glass to the luminaire housing and observe that the holding springbolts fit into the notches of the glass.
- Turn the glass clockwise until it is locked.
- Thus, you reach a safe and vibration-resistant holding of the glass.
- To release the glass from the luminaire housing, turn it counter-clockwise.
Replacement of the LED module · Maintenance
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system.
- Unscrew glass from luminaire housing by turning it counter-clockwise.
- Clean glass and luminaire regularly with solvent-free cleansers from dirt.
- Please follow the installation instructions for the LED module.
- Screw in glass by turning it clockwise as far as it will go.
- A broken glass must be replaced.
Spares
Spare glass 11 002 941 .1R G
LED power supply unit DEV-0365/700
LED module 3000 K LED-0530/930
Grommet 83 001 391
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com