Application

Recessed ceiling luminaire · indoor luminaire with adjustable broad spread light distribution.
With external DALI controllable power supply unit for installation into concrete ceilings or suspended ceilings.

Product description

Recessed ceiling downlights with external PSU
Luminaire made of aluminium alloy, aluminium and stainless steel
Ceiling trim ring made of metal, Colour velvet white
Clear safety glass
Reflector surface made of pure aluminium Optical silicone lens · BEGA Hybrid Optics®
Luminaire housing with 2 fixing claws and guide screws
Recessed opening ø 128 mm
Required installation depth 105 mm
1 connecting cable with strain relief and plug connector system for BEGA DALI- power supply unit
External LED power supply unit 350 mA 220-240 V 0/50-60 Hz DC 176-280 V
DALI controllable
A basic isolation exists between power cable and control line
Safety class IIIcon
– Conformity mark
Weight: 0.9 kg
This product contains light sources of energy efficiency class(es) F

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Installation

Luminaire housing must not be installed in heat-insulating material.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or revamping.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using two adjustable claws.
Installation in concrete ceilings:
To accommodate the luminaire and the external power supply unit we recommend using the installation housing 10 441.
Installation in suspended ceilings:
A recessed opening of ø 128 mm with a minimum installation depth of 105 mm is required.
The external power supply unit requires a minimum of 90 mm clearance above the ceiling.
The claws grip behind the ceiling cladding.
The minimum thickness of the ceiling cladding is 12 mm.
If the thickness is less, and if installation is to be effected in plasterboard ceilings, the back of the ceiling cladding must be reinforced in the region of the claws.
The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires.
The two connecting terminals marked DA, DA are provided for digital control purposes.
If these terminals are not assigned, the luminaire will work with full light output.
Pull cover ring (magnetic) off the installation ring of the pivoting housing.
Connect plug part of the luminaire with power supply unit.
Push external LED power supply unit and luminaire housing into the ceiling cut-out.
Luminaire housing and external LED power supply unit must not be installed in heat-insulating material.
Tighten guide screws.
When tightening the screws, the fixing claws must swivel onto the inside of the suspended ceiling. The luminaire is fixed.
When undoing the guide screws, the fixing claws swivel back and the luminaire can be removed.
Adjustment of the direction of radiation:
Undo both hexagon socket head screws and remove transportation lock. Adjust tilt angle and beam direction of the LED. Tighten latching screw.
Mount the cover ring onto installation ring of the housing (magnetic).

Lamp

Module connected wattage| 12 W
Luminaire connected wattage| 14 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 35 °C
51 255.1 K3
Module designation| LED-1148/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 1730 lm
Luminaire luminous flux| 1273 lm
Luminaire luminous efficiency| 90,9 lm / W

Light technique

Recessed luminaire with adjustable optical system, 0-30° swivel-mounted and ±180° infinitely rotatable.
Wide beam light distribution.
Half beam angle 46°
The symmetrical light cone can be modified to resemble flat beam light distribution for special lighting applications by replacing the cover glass.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Accessories

10 441 Installation housing
10 014 Exchangeable lens flat beam
For the accessories a separate instructions for use can be provided upon request.

Spares

Spare glass| 14 001 579
LED power supply unit| DEV-0434/350
LED module 3000 K| LED-1148/930
Reflector| 76 002 003