BEGA 51212.1 Ceiling Luminaire Downlight Instruction Manual

June 12, 2024
BEGA

51212.1 Ceiling Luminaire Downlight
Instruction Manual

Ceiling luminaire · downlight for indoor use
51 212.1

51212.1 Ceiling Luminaire Downlight

BEGA 51212 1 Ceiling Luminaire Downlight

Instructions for use
Application
Ceiling luminaire downlight · indoor luminaire with symmetrical wide beam light distribution.

Product description

Aluminium alloy housing, finish Colour velvet white Crystal glass, partially satin matt, with screw neck Light-diffusing silicone lens
Reflector made of pure anodised aluminium
2 mounting holes ø 4.5 mm
Distance apart 112 mm
Connecting terminals 2.5@
Earth conductor connection
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-275 V
DALI-controllable
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Conformity mark
Weight: 1.8 kg
This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lighting technology
Half beam angle 53°

Lamp
Module connected wattage Luminaire connected wattage Rated temperature Ambient temperature
51 212.1 K27
Module designation
Colour temperature
Colour rendering index
Module luminous flux
Luminaire luminous flux
Luminaire luminous efficiency
51 212.1 K3
Module designation
Colour temperature
Colour rendering index
Module luminous flux
Luminaire luminous flux
Luminaire luminous efficiency

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Remove mounting plate from the luminaire housing.
Unplug the earth conductor connection (plug contact).

Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface, it is mandatory to make sure that the mounting surface is connected conductive to the earth conductor of the luminaire!
Lead the power connecting cable through the mounting plate.
Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
Establish the earth conductor connection on the earthing screw (1) of the mounting plate.
Establish the earth conductor connection to the luminaire housing (plug contact).
Push silicone sleeves over the lines and establish the electrical connection to the terminals marked (L) and (N).
The two connecting terminals marked DA, DA are provided for digital control purposes.
If these terminals are not assigned, the luminaire will work with full light output.BEGA 51212 1 Ceiling Luminaire Downlight -
feager1

IMPORTANT:
To ensure secure connection, the luminaire housing must be positioned precisely in relation to the mounting plate.
Make sure that the vertical bar inside the luminaire housing is positioned precisely in the area of the mounting hole on the long bar of the mounting plate.
Press the luminaire housing firmly against the mounting plate and turn it clockwise firmly against the stop.
Open luminaire:
Unscrew glass from luminaire housing by turning it counter-clockwise.
To prevent the luminaire from turning on the mounting plate, hold the luminaire housing in place with one hand.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free  cleansers from dirt.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.

Spares

Spare glass 11 003 448 10M RG
LED power supply unit DEV-0402/610i
LED module 2700 K LED-0800/927
LED module 3000 K LED-0800/930
Reflector 76 001 775 M

BEGA Gantenbrink-Leuchten KG
· Postfach 31 60
· 58689 Menden
· info@bega.com
· www.bega.com
14.22 · Technical amendments reserved

Documents / Resources

| BEGA 51212.1 Ceiling Luminaire Downlight [pdf] Instruction Manual
51212.1 Ceiling Luminaire Downlight, 51212.1, Ceiling Luminaire Downlight, Luminaire Downlight, Downlight
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals