BEGA 88675 In Ground Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 88675 In Ground Luminaire

Product Information

The product is an in-ground luminaire with four-sided light sectors. It is designed for installation in compacted surfaces,paths, or floors. The luminaire is suitable for drive-over applications for vehicles with pneumatic tires, with a pressure load capacity of up to 1,000 kg (~10 kN). However, it should not be used for installation in road lanes where it may be exposed to horizontal strain due to braking, acceleration, and change of direction.

The product features a luminaire cover made of aluminium alloy, a luminaire housing made of cast stainless steel and stainless steel, and an optical lens made of silicate glass. It is equipped with a silicone gasket, a baseplate with 4 fixing holes, and a 1.8 m water-resistant connecting cable with a water stopper and a 1.2 m PVC cable conduit. The LED power supply unit has a voltage range of 220-240 V AC and a frequency range of 50-60 Hz, with a DC output voltage range of 198-264 V.

The product is classified as safety class I and has a protection class IP 67, which means it is dust-tight and protected against temporary immersion. It has a pressure load capacity of 1,000 kg (~10 kN) and an impact strength of IK10. The product is also energyefficient, with light sources  classified as energy efficiency class(es) D and E.

Product Usage Instructions

  1. Choose a suitable location for installation in compacted surfaces, paths, or floors.
  2. Ensure the installation area can support the pressure load capacity of up to 1,000 kg (~10 kN).
  3. Avoid installing the luminaire in road lanes where it may be exposed to horizontal strain.
  4. Prepare the installation site by creating a suitable opening or recess for the luminaire.
  5. Connect the luminaire to a suitable power source using the provided water-resistant connecting cable and PVC cable conduit.
  6. Ensure the voltage and frequency of the power source match the specifications of the LED power supply unit (220-240 V AC, 50-60 Hz).
  7. Securely fix the luminaire in place using the baseplate and the provided fixing holes.
  8. Test the functionality of the luminaire by turning on the power.
  9. Regularly clean and maintain the luminaire to ensure optimal performance and longevity.

Dimension

In-ground luminaire

Application

  • In-ground luminaire with four-sided light sectors.
  • For installation in compacted surfaces, paths or floors.
  • Drive-over luminaire for vehicles with pneumatic tyres.
  • For pressure load up to 1,000 kg (~10 kN).
  • Please note: Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.

Product description

  • Luminaire cover made of aluminium alloy BEGA Unidure® coating technology
  • Luminaire housing made of cast stainless steel and stainless steel
  • Steel grade number 1.4571
  • Optical lens is made of silicate glass
  • Silicone gasket
  • Baseplate with 4 fixing holes
  • elongated holes 5 mm wide
  • 75 x 75 mm spacing
  • 1,8 m water-resistant connecting cable 05RN8-F 3 G 1@ with implemented water stopper and 1.2 m PVC cable conduit
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 198-264 V
  • Safety class I
  • Protection class IP 67
  • Dust-tight and protection against temporary immersion
  • Pressure load 1,000 kg (~10 kN)
  • Impact strength IK10
  • Protection against mechanical
  • impacts < 20 joule
  • Maximum surface temperature 30 °C
  • (measured according to EN 60598 of ta 15 °C)
  • – Safety mark
  • – Conformity mark
  • Weight: 1.3 kg
  • This product contains light sources of energy efficiency class(es) D, E

Lamp

  • Module connected wattage 4 W

  • Luminaire connected wattage 6 W

  • Rated temperature ta = 25 °C

  • Ambient temperature ta max = 25 °C
    88 675 K27

  • Module designation 4x LED-0304/827

  • Colour temperature 2700 K

  • Colour rendering index CRI > 80

  • Module luminous flux 580 lm

  • Luminaire luminous flux 92 lm

  • Luminaire luminous efficiency 15,3 lm / W
    88 675 K3

  • Module designation 4x LED-0304/830

  • Colour temperature 3000 K

  • Colour rendering index CRI > 80

  • Module luminous flux 580 lm

  • Luminaire luminous flux 92 lm

  • Luminaire luminous efficiency 15,3 lm / W
    88 675 K4

  • Module designation 4x LED-0304/840

  • Colour temperature 4000 K

  • Colour rendering index CRI > 80

  • Module luminous flux 620 lm

  • Luminaire luminous flux 95 lm

  • Luminaire luminous efficiency 15,8 lm / W

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • We recommend fuse protection via a residual current circuit breaker to be provided by the customer.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Notice prior to installation:

  • To accept the maximum pressure load of 1,000 kg (~10 kN) a proper foundation must be provided by the customer.
  • The pressure load is transferred onto the foundation by the luminaire housing.
  • Foundation to be provided at site.
  • The foundation must be carried out on firm subgrade.
  • For the tightness of the luminaire it is important that the ground surface prepared later is either on the same level or slightly below top edge of the luminaire housing.
  • The lacquering of the luminaire cover must not be damaged.
  • Chemicals which have a corroding effect must not affect the luminaire housing.

Installation

  • Luminaire housing must not be installed in heat-insulating material.
  • Undo hexagon socket head screws.
  • Remove front plate with glass and gasket.
  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Dismantle the LED-board unit and disconnectthe connecting cable at the terminal of the LED board unit.
  • Position luminaire housing on the foundation (as described above) and fix it with enclosed or any other suitable fixing material.
  • At the same time note alignment to the illuminated surface.
  • Push in enclosed protective cover flushly into the luminaire housing.
  • The electrical connection at the luminaire connecting cable must be carried out on site according to the protection class and safety class.
  • We recommend to use a distribution box 70 730 or 71 053.
  • To protect the luminaire connecting cable from damage push the enclosed cable conduit over the cable.
  • Note correct configuration of the mains supply cable. Make mains supply connection at the brown (L), blue (N) and green-yellow lead (1).
  • After completion of all ground works cut, remove protective cover.
  • Clean luminaire housing and sealing surface.
  • The luminaire housing must be completely clean and absolutely dry.
  • The mains supply cable has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only.
  • Make electrical connection to the LED board unit.
  • Install the LED board and place safety glass with gasket into the housing.
  • Make sure that gasket is positioned correctly.
  • Put on luminaire cover and tighten the screws evenly and firmly.
  • Torque 2 Nm.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.
  • Corrosive chemicals must not come in contact with the luminaire.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the electrical installation.
  • Clean dirt and deposits from key openings of screw head. Do not use a high pressure cleaner.
  • Undo hexagon socket head screws.
  • Remove front plate with glass and gasket.
  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Dismantle the LED-board unit and disconnect the connecting cable at the terminal of the LED board unit.
  • Clean the glass and luminaire housing using only suitable cleansers.
  • The luminaire housing must be completely clean and absolutely dry.
  • Make electrical connection to the new LED board unit.
  • Install the LED board and place safety glass with gasket into the housing.
  • Make sure that gasket is positioned correctly.
  • Put on luminaire cover and tighten the screws evenly and firmly.
  • Torque 2 Nm.

Accessories
70 730 Distribution box for installation in soil with 7 cable entries
Connection terminals 5 x 4@

Spares
Spare glass 11 002 744 .2
LED power supply unit DEV-0238/350
LED module 2700 K LED-0304/827
LED module 3000 K LED-0304/830
LED module 4000 K LED-0304/840
Gasket Glas 83 001 795

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals