Product Information
The product is an in-ground luminaire with four-sided light sectors. It is designed for installation in compacted surfaces,paths, or floors. The luminaire is suitable for drive-over applications for vehicles with pneumatic tires, with a pressure load capacity of up to 1,000 kg (~10 kN). However, it should not be used for installation in road lanes where it may be exposed to horizontal strain due to braking, acceleration, and change of direction.
The product features a luminaire cover made of aluminium alloy, a luminaire housing made of cast stainless steel and stainless steel, and an optical lens made of silicate glass. It is equipped with a silicone gasket, a baseplate with 4 fixing holes, and a 1.8 m water-resistant connecting cable with a water stopper and a 1.2 m PVC cable conduit. The LED power supply unit has a voltage range of 220-240 V AC and a frequency range of 50-60 Hz, with a DC output voltage range of 198-264 V.
The product is classified as safety class I and has a protection class IP 67, which means it is dust-tight and protected against temporary immersion. It has a pressure load capacity of 1,000 kg (~10 kN) and an impact strength of IK10. The product is also energyefficient, with light sources classified as energy efficiency class(es) D and E.
Product Usage Instructions
- Choose a suitable location for installation in compacted surfaces, paths, or floors.
- Ensure the installation area can support the pressure load capacity of up to 1,000 kg (~10 kN).
- Avoid installing the luminaire in road lanes where it may be exposed to horizontal strain.
- Prepare the installation site by creating a suitable opening or recess for the luminaire.
- Connect the luminaire to a suitable power source using the provided water-resistant connecting cable and PVC cable conduit.
- Ensure the voltage and frequency of the power source match the specifications of the LED power supply unit (220-240 V AC, 50-60 Hz).
- Securely fix the luminaire in place using the baseplate and the provided fixing holes.
- Test the functionality of the luminaire by turning on the power.
- Regularly clean and maintain the luminaire to ensure optimal performance and longevity.
Dimension
In-ground luminaire
Application
- In-ground luminaire with four-sided light sectors.
- For installation in compacted surfaces, paths or floors.
- Drive-over luminaire for vehicles with pneumatic tyres.
- For pressure load up to 1,000 kg (~10 kN).
- Please note: Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.
Product description
- Luminaire cover made of aluminium alloy BEGA Unidure® coating technology
- Luminaire housing made of cast stainless steel and stainless steel
- Steel grade number 1.4571
- Optical lens is made of silicate glass
- Silicone gasket
- Baseplate with 4 fixing holes
- elongated holes 5 mm wide
- 75 x 75 mm spacing
- 1,8 m water-resistant connecting cable 05RN8-F 3 G 1@ with implemented water stopper and 1.2 m PVC cable conduit
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 198-264 V
- Safety class I
- Protection class IP 67
- Dust-tight and protection against temporary immersion
- Pressure load 1,000 kg (~10 kN)
- Impact strength IK10
- Protection against mechanical
- impacts < 20 joule
- Maximum surface temperature 30 °C
- (measured according to EN 60598 of ta 15 °C)
- – Safety mark
- – Conformity mark
- Weight: 1.3 kg
- This product contains light sources of energy efficiency class(es) D, E
Lamp
-
Module connected wattage 4 W
-
Luminaire connected wattage 6 W
-
Rated temperature ta = 25 °C
-
Ambient temperature ta max = 25 °C
88 675 K27 -
Module designation 4x LED-0304/827
-
Colour temperature 2700 K
-
Colour rendering index CRI > 80
-
Module luminous flux 580 lm
-
Luminaire luminous flux 92 lm
-
Luminaire luminous efficiency 15,3 lm / W
88 675 K3 -
Module designation 4x LED-0304/830
-
Colour temperature 3000 K
-
Colour rendering index CRI > 80
-
Module luminous flux 580 lm
-
Luminaire luminous flux 92 lm
-
Luminaire luminous efficiency 15,3 lm / W
88 675 K4 -
Module designation 4x LED-0304/840
-
Colour temperature 4000 K
-
Colour rendering index CRI > 80
-
Module luminous flux 620 lm
-
Luminaire luminous flux 95 lm
-
Luminaire luminous efficiency 15,8 lm / W
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- We recommend fuse protection via a residual current circuit breaker to be provided by the customer.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Notice prior to installation:
- To accept the maximum pressure load of 1,000 kg (~10 kN) a proper foundation must be provided by the customer.
- The pressure load is transferred onto the foundation by the luminaire housing.
- Foundation to be provided at site.
- The foundation must be carried out on firm subgrade.
- For the tightness of the luminaire it is important that the ground surface prepared later is either on the same level or slightly below top edge of the luminaire housing.
- The lacquering of the luminaire cover must not be damaged.
- Chemicals which have a corroding effect must not affect the luminaire housing.
Installation
- Luminaire housing must not be installed in heat-insulating material.
- Undo hexagon socket head screws.
- Remove front plate with glass and gasket.
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Dismantle the LED-board unit and disconnectthe connecting cable at the terminal of the LED board unit.
- Position luminaire housing on the foundation (as described above) and fix it with enclosed or any other suitable fixing material.
- At the same time note alignment to the illuminated surface.
- Push in enclosed protective cover flushly into the luminaire housing.
- The electrical connection at the luminaire connecting cable must be carried out on site according to the protection class and safety class.
- We recommend to use a distribution box 70 730 or 71 053.
- To protect the luminaire connecting cable from damage push the enclosed cable conduit over the cable.
- Note correct configuration of the mains supply cable. Make mains supply connection at the brown (L), blue (N) and green-yellow lead (1).
- After completion of all ground works cut, remove protective cover.
- Clean luminaire housing and sealing surface.
- The luminaire housing must be completely clean and absolutely dry.
- The mains supply cable has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only.
- Make electrical connection to the LED board unit.
- Install the LED board and place safety glass with gasket into the housing.
- Make sure that gasket is positioned correctly.
- Put on luminaire cover and tighten the screws evenly and firmly.
- Torque 2 Nm.
Cleaning · Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high pressure cleaners.
- Corrosive chemicals must not come in contact with the luminaire.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the electrical installation.
- Clean dirt and deposits from key openings of screw head. Do not use a high pressure cleaner.
- Undo hexagon socket head screws.
- Remove front plate with glass and gasket.
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Dismantle the LED-board unit and disconnect the connecting cable at the terminal of the LED board unit.
- Clean the glass and luminaire housing using only suitable cleansers.
- The luminaire housing must be completely clean and absolutely dry.
- Make electrical connection to the new LED board unit.
- Install the LED board and place safety glass with gasket into the housing.
- Make sure that gasket is positioned correctly.
- Put on luminaire cover and tighten the screws evenly and firmly.
- Torque 2 Nm.
Accessories
70 730 Distribution box for installation in soil with 7 cable entries
Connection terminals 5 x 4@
Spares
Spare glass 11 002 744 .2
LED power supply unit DEV-0238/350
LED module 2700 K LED-0304/827
LED module 3000 K LED-0304/830
LED module 4000 K LED-0304/840
Gasket Glas 83 001 795