BEGA 50 100 Large Area Ceiling and Wall Luminaire Instructions
- June 12, 2024
- BEGA
Table of Contents
BEGA 50 100 Large Area Ceiling and Wall Luminaire
Product Information
Safety| The installation and operation of this luminaire are subject to
national safety regulations. Installation and commissioning may
only be carried out by a qualified electrician. The manufacturer
accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be
considered the manufacturer.
---|---
Overvoltage Protection| The electronic components installed in the luminaire
are
protected against overvoltage in accordance with DIN EN 61547. To
achieve an additional protection against e.g. transients, etc., we
recommend separate overvoltage protection components. You can find
them on our website at www.bega.com.
Lamp Module Connected Wattage| 92.4 W
Luminaire Connected Wattage| 101 W
Rated Temperature| Ambient temperature: 25°C
Bemessungstemperatur Umgebungstemperatur: 35°C
Module Designation| 4x LED-0704/930
Colour Temperature| 3000 K
Colour Rendering Index| CRI > 90
Module Luminous Flux| 14960 lm
Luminaire Luminous Flux| 12365 lm
Luminaire Luminous Efficiency| 122.4 lm/W
Spares| (Synthetic cover)
LED- (LED power supply unit)
LED-Modul 3000 K (LED module 3000 K)
Product Usage Instructions
- Wall Mounting:
- Pick up the luminaire and connect the plug-in terminal of the luminaire to the socket of the mounting plate.
- Place the key holes at the rear of the fitting for the locking mechanism over the turn-and-lock parts of the outrigger arms and move as far as the stop.
- Turn the luminaire clockwise and tighten as far as the stop.
- To prevent unintentional loosening of the luminaire cover:
- Turn the torx screw (T 10) in the edge of the luminaire housing until it stops (lock).
- Replacing the LED module:
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Defective luminaire cover must be replaced.
- Close the luminaire.
Application
- Ceiling and wall luminaire · indoor luminaire made of impact resistant synthetic diffuser and metal housing.
- Large-area luminaire with high light output and high uniform light distribution.
Product Description
- Large-area LED luminaire »MAXIMA« Metal luminaire mounting plate, finish Colour white
- Light-diffusing synthetic luminaire cover
- Silicone gasket
- Mounting plate with 2 key holes, pitch circle ø 220 mm and 3 elongated holes, pitch circle ø 790 mm, width 6 mm
- Connecting terminals 2.5@ · Plug system
- Earth conductor terminal: 2-pole connecting terminal for digital control
- LED power supply unit: 220-240 V 0/50-60 Hz
- DC 176-280 V
- During DC operation the LED power is reduced to 15 %
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class: I
- Impact strength IK10
- Protection against mechanical impacts < 20 joule
- : Safety mark
- CE: Conformity mark
- Weight: 16.5 kg
- This product contains light sources of energy efficiency class(es) D
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Specifications
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp
- Module connected wattage: 92.4 W
- Luminaire connected wattage: 101 W
- Rated temperature: ta = 25 °C
- Ambient temperature; ta max = 35 °C
50 100 K3
- Module designation: 4x LED-0704/930
- Colour temperature: 3000 K
- Colour rendering index: CRI > 90
- Module luminous flux: 14960 lm
- Luminaire luminous flux: 12365 lm
- Luminaire luminous efficiency: 122,4 lm / W
Notice prior to installation
- For fixing the luminaire please consider sufficient load capacity of ceiling or wall.
- For the electrical connection the position of the entry openung of the mounting plate must be considered (see sketch).
- General fixing material may not be suitable for all applications.
- Note approval of building supervision.
- It is essential to make sure that the outrigger arms of the mounting plate do not lose their exact arrangement of 3 x 120° when mounting them on the mounting surface!
Installation
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Unpack mounting plate.
- Pass the power connecting cable through the opening in the mounting plate.
- Fasten the mounting plate with the supplied or other suitable fastening materials to the mounting surface – key holes -.
- Mark the fastening points of the outrigger arms precisely on the mounting surface.
- Fasten the outrigger arms of the mounting plate with the supplied or other suitable fastening materials to the mounting surface – elongated holes -.
- Make sure that all the fastening points of the mounting plate and the outrigger arms are fully screw-fitted – see drawing!
- Make the earth conductor connection and the electrical connection to the terminals of the mounting plate – plug connection.
- For digital control please use the connecting terminal DA, DA.
- In case this terminal is not used the luminaire will be operated at full light output.
- Unpack luminaire and lift it with enclosed gloves.
_ ATTENTION: _In order to avoid deformation under its own weight, do not deposit luminaire on its domed synthetic cover outside the package!
Wall mounting
- Pick up the luminaire and connect the plug-in terminal of the luminaire to the socket of the mounting plate.
- Place the key holes at the rear of the fitting for the locking mechanism over the turn-and-lock parts of the outrigger arms and move as far as the stop.
- Turn the luminaire clockwise and tighten as far as the stop.
Ceiling installation
- IMPORTANT: When the luminaire is installed on the ceiling, it is essential to use the provided steel retention wires.
- Pick up the luminaire and hook the steel retention wires by the spherical nipple into the recesses of the outrigger arms.
- Use a suitable tool to bend the lateral metal lugs towards the ceiling – see drawing.
- This will ensure that the spherical nipple of the steel retention wire cannot disconnect itself.
- Connect the plug-in terminal of the luminaire to the socket of the mounting plate.
- Place the key holes at the rear of the fitting for the locking mechanism over the turn-and-lock parts of the outrigger arms and move as far as the stop.
- Turn the luminaire clockwise and tighten as far as the stop.
- To prevent unintentional loosening of the luminaire cover, turn the torx screw (T 10) in the edge of the luminaire housing until it stops (lock).
Maintenance
Cleaning /Maintenance
- Clean luminaire regularly with solvent-free cleaning agents to remove dirt.
- A defective synthetic cover must be replaced.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the
- LED module.
- Defective luminaire cover must be replaced.
- Close the luminaire.
Spares
- Synthetic cover: 15 000 473
- LED power supply unit: DEV-0300/2100i
- LED module 3000 K: LED-0704/930
BEGA Gantenbrink-Leuchten KG
- Postfach 31 60 · 58689 Menden
- info@bega.com
- www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>