Application

Wall washer · indoor luminaire for the glare free illumination of wall surfaces with the mounting surface being the reflection surface. The light emits upwards and downwards.

Product description

Die-cast aluminium and aluminium housing, finish Colour velvet black Crystal glass, inside matt Reflector made of pure anodised aluminium 2 mounting holes ø 4.8mm Distance apart 200 x 65mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5mm, max. 5G1.5@ Connection terminal 2.5@ Earth conductor connection 2-pole connecting terminal for digital control LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V DALI-controllable
Basic insulation is provided between the mains and control cables BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components Safety class I Impact strength IK07
Protection against mechanical impacts < 2 joule
Safety mark
Conformity mark
Weight: 2.0 kg
This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 24.6 W
Luminaire connected wattage 28.4 W
Rated temperature ta=25 °C
Ambient temperature ta max=25 °C

50 146.5K3

Module designation 2x LED-0696/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 3620 lm
Luminaire luminous flux 2571 lm
Luminaire luminous efficiency 90,5 lm/W

50 146.5K4

Module designation 2x LED-0696/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 3770 lm
Luminaire luminous flux 2678 lm
Luminaire luminous efficiency 94,3 lm/W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo screws and lift off luminaire top.
Loosen earth connection (plug connection) and
LED-connection between luminaire top and luminaire base.
Lead the mains supply cable through the cable entry of the luminaire base.
Note position of application of the luminaire “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
Make earth connection (plug connection) and LED-connection between luminaire top and luminaire base again.
Install luminaire top part, adjust it and tighten screws evenly

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
Disconnect the system and open the luminaire. Uninstall the reflector.
Please follow the installation instructions for the LED module.
Install the reflector. Defective glass must be replaced. Close the luminaire.

Replacement of the glass

Undo screws and lift off luminaire top.
Loosen earth connection (plug connection) and LED-connection between luminaire top and luminaire base.
Loosen reflector screws, separate earth connection and remove reflector.
Loosen screws of the glass retaining springs and remove glass retaining springs from the luminaire top.
Remove damaged glass. Insert replacement glass.
Reinstall glass retaining springs and tighten screws on both sides.
Insert reflector into luminaire top part, makeearth connection to reflector and tighten reflector screws (0,6 Nm).
Make earth connection (plug connection) and
LED-connection between luminaire top and luminaire base again.
Install luminaire top part, adjust it and tighten screws evenly

Spares
LED power supply unit DEV-0388/700
LED module 3000 K LED-0696/930
LED module 4000 K LED-0696/940
Reflector 76 001 510