ecler eCA120DN Dante Interface Amplifier User Manual
- June 13, 2024
- ecler
Table of Contents
- eCA120DN Dante Interface Amplifier
- IMPORTANT REMARK
- IMPORTANT SAFETY INSTRUCTIONS
- IMPORTANT NOTE
- INTRODUCTION
- KEY FEATURES
- PACKING CONTENT
- POSITIONING AND FITTING
- CONNECTING
- OPERATION AND USAGE
- CLEANING
- FRONT PANEL
- REAR PANEL
- TECHNICAL CHARACTERISTICS
- BLOCK DIAGRAM
- eCA120DN:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
eCA120DN / eCA120HZDN
COMPACT AMPLIFIERS
DANTE™/AES67 Interface Amplifier
eCA120DN Dante Interface Amplifier
USER MANUAL
IMPORTANT REMARK
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
WARNING: SHOCK HAZARD – DO NOT OPEN
AVIS: RISQUE DE CHOC ELECTRIQUE – NE PAS OUVRIR
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance
(servicing)instructions in the literature accompanying the appliance.
WARNING (If applicable): The terminals marked with symbol of may be of
sufficient magnitude to constitute a risk of electric shock. The external
wiring connected to the terminals requires installation by an instructed
person or the use of ready-made leads or cords.
WARNING: To prevent fire or shock hazard, do not expose this equipment to
rain or moisture.
WARNING: An apparatus with Class I construction shall be connected to a
mains socket-outlet with a protective earthing connection.
IMPORTANT SAFETY INSTRUCTIONS
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with dry cloth.
- Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
- Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
- Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug the apparatus during lightening sorts or when unused for long periods of time.
- Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
- Disconnecting from mains: When switching off the POWER switch, all the functions and light indicators of the unit will be stopped, but fully disconnecting the device from mains is done by unplugging the power cable from the mains input socket. For this reason, it always shall remain easily accessible.
- Equipment is connected to a socket-outlet with earthing connection by means of a power cord.
- The marking information is located at the bottom of the unit.
- The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on apparatus. 18. This product is for indoor use only.
NOTE: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense.
WARNING: This product must not be discarded, under any circumstance, as
unsorted urban waste. Take to the nearest electrical and electronic waste
treatment centre.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may
be caused to people, animal or objects due to failure to comply with the
warnings above.
IMPORTANT NOTE
Thank you for choosing our Ecler eCA120DN / eCA120HZDN DANTE™/AES67 Interface
Amplifier!
It is VERY IMPORTANT to carefully read this manual and to fully understand
its contents before any connection in order to maximize your use and get the
best performance from this equipment.
To ensure optimal operation of this device, we strongly recommend that its
maintenance be carried out by our authorised Technical Services.
All ECLER products are covered by warranty, please refer to
www.ecler.com or the warranty card included with this
product for the period of validity and conditions.
INTRODUCTION
eCA120DN is a 2 x 60 WRMS @ 4Ω high efficiency (class D) stereo compact
amplifier. It features 2 x analogue audio inputs and 2 x DANTE™/AES67 audio
inputs, both with selectable priority function (over the other input signal)
as well as an auxiliary audio
output. Auto stand-by function (selectable) and fanless design (100% silent).
It also has a remote control volume port compatible with ECLER Wpa wall-panel
control series. Universal external power supply included.
eCA120HZDN is a 120 WRMS @ 70V / 100V efficiency (class D) mono compact
amplifier for high impedance lines, with the same features than eCA120DN.
KEY FEATURES
- 2 x 60 W RMS @ 4 Ω output (eCA120DN)
- 1 x 120W RMS @ 70V / 100V output (eCA120HZDN)
- 1 x auxiliary audio output (Euroblock connector), for connecting to a sub-woofer unit e.g.
- 1 x unbalanced stereo input (LINE INPUT), with dual RCA connector and 3-in Euroblock connector
- 2 x DANTE™/AES67 audio input (DANTE INPUT), with RJ-45 connector
- Selectable PRIORITY FUNCTION with selectable priority signal: the analogue audio input (LINE INPUT) can be selected as priority signal over the DANTE™/AES67 audio input (DANTE INPUT), or vice versa.
- Priority release time adjustment (FAST / SLOW).
- Selectable AUTO STANDBY function: in the absence of an audio signal the unit automatically goes into STANDBY mode, minimizing power consumption.
- Gain adjust of audio inputs on front panel (trimmers)
- Local volume control by knob
- Remote volume control (RJ-45 connector.) via Wpa wall-panel control series (010 VDC).
- Lightweight, silent, high-performance amplifier (fan-free convection cooling)
- External, universal power supply (included)
PACKING CONTENT
- eCA120DN or eCA120HZDN
- Universal external power supply DC24V
- 2 x 2-pin Euroblock connectors
- 2 x 3-pin Euroblock connectors
- 4 x adhesive legs for positioning the loudspeakers on a desktop
- Quick start guide
- Warranty card
POSITIONING AND FITTING
WARNING: Non-compliance with the instructions or neglecting warnings may cause malfunction or even damage the unit:
- Avoid turning on the device without the speakers connected to its outputs and without having previously set the volume/gain controls to minimum level.
- Always use shielded cables to make connections between devices.
- In an amplifier, avoid placing the speaker output cables close to other signal cables (micro, line…). This may cause the system to oscillate, damaging the amplifier and speakers.
eCA120DN/eCA120HZDN is suitable for installation on a wall or under a
surface (table, shelf, cupboard, etc.), thanks to its design and layout of its
connectors, controls and LED indicator lights. Along with the optional
1UHRMKIT accessory (not included), it is also possible to install the unit in
a standard 19” rack (1RU height).
This unit is intended for users with low technical expertise, for this reason,
all input gain controls are accessible by means of an adjustment turnscrew,
except for the output level adjustments, controlled with classic rotary knobs,
easily accessible from the front panel. Thanks to its low consumption and heat
dissipation the eCA120DN / eCA120HZDN doesnot require forced cooling, however,
it must be prevented from installing the unit in dusty environments with
extreme temperature and/or humidity conditions.
The unit must be away from noise and interference sources (voltage variators,
electric engines, etc.) as well as mains cables.
CONNECTING
8.1 Mains connection
The amplifier is powered by alternating current through its external power
source: 100240 VAC and 50-60 Hz.
The atmosphere should be as dry and dust free as possible. Do not expose the
unit to rain or water splashes. Do not place liquid containers or incandescent
objects like candles on top of the unit.
Should any work or connection / disconnection task be done, always disconnect
the unit from the mains supply. There are no elements that can be manipulated
by the user inside the unit.
To avoid buzzing, do not allow the power cable to intertwine with the shielded
cables that transport the audio signal.
8.2 DANTE™ audio inputs
eCA120DN / eCA120HZDN allows the reception of 2 DANTE™/AES67 audio signals via
Ethernet by means of an RJ-45 connector. Routing of DANTE™/AES67 audio signals
trough the Ethernet network is achieved thanks to the Dante Controller
software. To learn more, check the developer’s documentation:
www.audinate.com/products/software/dante-
controller
Make sure that the front panel switch (INPUT SELECT) is in DANTE position, and
then adjust the DANTE input gain with the front panel trimmer (DANTE INPUT)
until the input audio signal is appropriate.
8.3 Analogue audio inputs
eCA120DN / eCA120HZDN input channel only supports stereo line signals (or two
mono signals). It has an unbalanced stereo connection with dual RCA connector
and 3-pin Euroblock connector (LINE IN). This input is designed to support
-6dBV to 0dBV signals, given that the rotary volume control of the front panel
provides an extra +6dB of gain at its maximum position.
This audio input can receive signals from CD players, radio tuners, mixing
consoles, media players, audio outputs of computers and tablets, etc..
LINE IN connections are linked, so that when you use one of them as an audio
signal input for your unit, you can use the other to send that signal to
another unit or external equipment.
8.4 Audio output connections
eCA120DN:
The powered output (OUT L y R) uses a Euroblock connector.
The connection cable that connects the eCA120DN connectors and the speakers
should be good quality, with a suitable cross section and as short as
possible.
Keep in mind that, minimum nominal impedance for each cannel is 4 . For a
proper performance, the unit must not work under lower impedance than
previously specified, under no circumstances.
eCA120HZDN:
The powered output (OUTPUT) uses a Euroblock connector with a common terminal
(0V), a terminal for a 70V line and another terminal for a 100V line. Always
use the common terminal and, depending on the type of speaker in the system,
one of the two
others, 70 / 100V, to feed the loudspeaker line.
The connection cable that connects the eCA120HZDN connectors and the speakers
should be good quality, with a suitable cross section and as short as
possible.
The OUTPUT provides a powered version of the mono-converted input signal.
Remember that the total power used by the speakers connected to the eCA120HZDN
output should not exceed the maximum power it can provide.
In addition, eCA120DN and eCA120HZDN feature an aux audio output (AUX OUTPUT)
with Euroblock connector. This stereo audio signal is identical to the powered
signal, but with LINE level. Perfect to connect an additional audio system
like a self-powered subwoofer for bass reinforcement.
8.5 Remote control port
The RJ-45 (REMOTE VOLUME) connector allows to connect a WpaVOL-type wall
control panel (or another model of the Wpa series) to adjust the overall
output volume. The connection is made with a standard CAT5/CAT6 cable between
the Wpa wall panel and the REMOTE connector of the eCA120DN / eCA120HZDN.
OPERATION AND USAGE
9.1 Start up
Start up the eCA120DN / eCA120HZDN by connecting the equipment to an external
power source to which the DC IN 24V connector of the amplifier has already
been connected. The LED indicator ON/STBY immediately lights up on the front
panel. We recommend you turn on all the devices in the following order: sound
sources, mixer, equalisers, active filters and processors and, finally power
amplifiers. Powering off should be done by following the exact reverse
sequence. Following this order, the introduced noise due to turning on or
switching off the devices will not affect those further on in the chain and
will be inaudible.
Once turned on, the front volume control (VOLUME) and the controller connected
to the REMOTE VOLUME port (if any) may be used to set the output volume of the
signal powered by the unit.
To select the audio input signal, use the switch located at the front panel
(INPUT SELECT).
9.2 Priority function
When the priority function (PRIO MODE) is activated, one of the input signals
will have priority over the other, that is to say, when signal presence is
detected in the priority input (signal level exceeds the threshold) the input
signal selected with INPUT SELECT switch will be attenuated.
For instance, if priority function is activated (PRIO MODE in ON position) and
the selected audio signal is DANTE™/AES67 (INPUT SELECT in DANTE position),
the priority audio signal will be the analogue input. The priority mode allows adjusting the attenuated signal
recovery time (PRIO RELEASE TIME), by means of a switch FAST / SLOW located at
the rear panel.
9.3 Auto-standby function
The AUTO STANDBY function (idle or low consumption mode) means you can install
the eCA120DN / eCA120HZDN in inaccessible places and leave the device
connected to the mains power supply permanently because when no signal is
detected, it automatically goes into standby mode, saving energy.
To enable the AUTO STANDBY mode, the switch labelled “AUTO STBY” on the rear
panel has to be in the ON position. When it is enabled and after 2 minutes or
more without any audio signal at the audio input of the device (or a very weak
signal, lower than the activation threshold), the eCA120DN / eCA120HZDN will
automatically switch into standby mode, lighting up the red ON/STBY LED
located on the front panel of the device. When a valid audio signal is
detected in any of the inputs, the amplifier leaves standby mode and starts
operating normally again and the ON/STBY LED goes green.
When enabling the AUTO STANDBY mode with the front panel switch (ON position),
one of the 2 following assumptions may occur:
a) There is NO audio signal in the inputs. Result: the amplifier immediately
goes intoAUTO STANDBY mode.
b) There is an audio signal in the inputs. Result: the amplifier stays active.
9.4 LED indicators
-
SP: The signal presence or SP LED indicator shows that there is a signal in the amplifier input. This lights up when the input level reaches the established detection threshold.
-
CLIP: The saturation (or cut off) CLIP LED indicator comes on when the signal delivered to the speakers is close to the amplifier’s clipping or saturation level. Input signals should be set to ensure the CLIP indicators never stay on, but that they do so at most to the beat of the lowest sound frequencies. Otherwise the powered signal will be distorted with low quality and low intelligibility.
Note: If the input signal is too high, the CLIP indicator lighting up very frequently over a short time interval (a few seconds), the amplifier may go into protection mode, being muted to return to normal operation in a short time. -
ON/STBY: The green light comes on when the equipment is in normal operating mode and it goes red when it is in standby or low consumption mode (STANDBY).
9.5 Setup switches
- INPUT SELECT: selects the audio input (program audio)
- LINE IN: analogue audio input
- DANTE: DANTE™/AES67 audio input
- PRIO MODE: turns ON/OFF the priority function.
- PRIO RELEASE TIME: sets the attenuated signal (program audio) recovery time (FAST / SLOW recovery).
- AUTO STBY: turns ON/OFF the AUTO STANDBY function. When the function is on, the eCA120DN / eCA120HZDN will automatically go into STANDBY or low consumption mode in the absence of audio signals in its inputs.
CLEANING
eCA120DN / eCA120HZDN must not be cleaned with solvents or abrasive substances which may damage the prints. Clean using a dry cloth. Under no circumstances allow water to enter any of the orifices in the equipment.
FRONT PANEL
- INPUT SELECT (audio input) switch
- PRIO MODE priority function switch
- DANTE INPUT (DANTE™/AES67 audio) adjust trimmer
- LINE INPUT (analogue audio) adjust trimmer
- MASTER VOLUME control
- SP (signal presence) indicator light
- CLIP indicator light
- ON/STBY (on / standby) indicator light
REAR PANEL
-
DANTE INPUT RJ-45 connector,
-
PRIO RELEASE TIME attenuated signal recovery time switch (FAST / SLOW)
-
AUTO-STBY (ON / OFF) switch
-
LINE INPUT RCA connector
-
LINE INPUT Euroblock connector
-
REMOTE VOLUME RJ-45 connector
-
AUX. OUTPUT (auxiliary LINE output) Euroblock connector
-
A OUT L / R powered outputs
16B 0V/70V/100V OUTPUT high impedance output, -
DC24V power connector
TECHNICAL CHARACTERISTICS
| eCA120DN| eCA120HZDN
---|---|---
Analogue input / output
Power
Frequency response
THD+Noise @ 1kHz Full Pwr. SPKR OUT
Channel crosstalk @ 1kHz
Inputs Sensitivity nom/Impedance
Volume adjust
High Pass Filter (internal, no removable)
Signal Noise Ratio|
2x56W@4Ω 1% THD
2x68W@4Ω 10% THD
2x34W@8Ω 1% THD
2x41W@8Ω 10% THD
15Hz – 25kHz (-3dB)
< 0.15%
|
98W@ 100Ω 1% THD 100V
98W@ 50Ω 1% THD 70V
75Hz – 25kHz (-3dB)
< 0.07%
65dB
0dBV/>20kΩ
-∞ to +6dBV
NA
85dB| 70Hz
70dB
DANTE™/AES67 input / output
Volume adjust| -∞ to 0dBV
Resolution| 24 bits
Dynamic range| 100dB
DANTE™/AES67 audio interface
Dante Network outputs| 2
Latency| 1 / 2 / 5 ms (selectable)
Connector| 1 x RJ45
Cable length between devices| 100m CAT5 or CAT5e / CAT6
Priority and input mode
Priority function| Threshold: -30dB
Priority release time (with Fade-in)| Fast: 4seg.
Slow:18 seg.
Miscellaneous
Remote control
Auto standby
Signal present
Input select button
Priority mode button| Master Volume
Analog. 0 -10V based (RJ45 connector)
Time: 90 seg. (aprox.)
Threshold: -40dBV (L&R)
Threshold -40dBV (L&R)
Pressed: Dante™ INPUT
Released: Line INPUT
Pressed: Mode ON
Released: Mode OFF
Supply
DC supply
Mains (using supplied DC adapter)| 24V
100-240VAC + External PSU 24VDC
Power consumption
Pink noise, 1/8 power @ 4 ohm
Pink noise, 1/3 power @ 4 ohm
Standby mode (time 2 minutes)| 38,9VA / 26,6W
66,4VA / 56,9W
14,7VA / 4,9W| 38,4VA / 26,3W
65,4VA / 55,0W
14,3VA / 4,5W
Mechanical
Dimensions WxHxD
Weight| 200x44x120mm
0,90 kg.| 435x44x120mm
2,8 kg.
BLOCK DIAGRAM
eCA120DN:
eCA120HZDN:
All product characteristics are subject to variation due to production
tolerances.
NEEC AUDIO BARCELONA S.L.
reserves the right to make changes or improvements in the design or
manufacturing that may affect these product specifications.
For technical queries contact your supplier, distributor or complete the
contact form on our website, in Support / Technical
requests.
Motors, 166‐168 08038 Barcelona ‐ Spain ‐ (+34) 932238403
information@ecler.com
www.ecler.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>