BEGA 24098 Wall Luminaire with Emergency Lighting Function Instruction Manual

June 12, 2024
BEGA

BEGA 24098 Wall Luminaire with Emergency Lighting Function

Product Information

Product Name Wall Luminaire with Emergency Lighting Function
Product Model 24 098
IP Rating IP 65
Voltage Range 120 V – 240 V
Installation Position Bottom (Unten)
Emergency Operation Duration 3 hours

Product Usage Instructions

  1. The installation and commissioning of this luminaire must be carried out by a qualified electrician.
  2. Ensure compliance with national safety regulations.
  3. Do not make any modifications to the luminaire without proper authorization.
  4. For additional protection against overvoltage, it is recommended to use separate overvoltage protection components available on the manufacturer’s website at www.bega.com.
  5. Connect the lamp module to the luminaire according to the specified wattage (13.4 W or 19 W).
  6. Ensure the ambient temperature during operation is within the range of 25°C to 45°C
  7. For emergency lighting function, affix the appropriate label on the luminaire based on the desired mode (self-contained, non-maintained, maintained) and duration (180 minutes).
  8. If operating the luminaire in continuous mode, cover the “0” on the additional label with the enclosed “1” sticker.
  9. Affix the additional labels and voltage/frequency label provided to the luminaire in a visible position from the outside.

DIMENSIONS

BEGA-24098-Wall-Luminaire-with-Emergency-Lighting-Function-
fig-1

Instructions for use

Application
Wall luminaire with emergency lighting function according to DIN EN 60598-2-22 and DIN VDE 0108-100 for integration in emergency escape lighting systems. With integrated single battery for 3 hours’ emergency operation in the event of a power failure.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Safety glass with optical structure
  • Silicone gasket
  • Reflector made of pure anodised aluminium
  • 2 mounting holes ø 5 mm
  • Distance apart 240 mm
  • 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@
  • Connecting terminal and earth conductor terminal 2.5@
  • 2-pole connecting terminal for digital control
  • Emergency lighting device with self-test function
  • 220-240 V y 50/60 Hz
  • LiFePo4-battery for 3 hours’
  • Emergency lighting operation at -20° to 45 °C
  • Integrated heater 11.3 W with integrated thermostat
  • BEGA Ultimate Driver®
  • LED power supply unit 220-240 V y 50/60 Hz
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK08
  • Protection against mechanical
  • impacts < 5 joule
  • CE – Conformity mark
  • Weight: 3.8 kg
  • This product contains light sources of energy efficiency class(es) B, C

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 13.4 W
  • Luminaire connected wattage 19 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C

24 098 K3

  • Module designation LED-0731/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2650 lm
  • Luminaire luminous flux 1429 lm
  • Luminaire luminous efficiency 75,2 lm / W

24 098 K4

  • Module designation LED-0731/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2725 lm
  • Luminaire luminous flux 1469 lm
  • Luminaire luminous efficiency 77,3 lm / W

With emergency lighting, a luminous flux of 360 lm is achieved.

  • X self-contained
  • 0 non-maintained
  • 1 maintained
  • A including test device
  • B including remote rest mode
  • 180 to indicate 3 h duration

Please note:

  • If the luminaire is operated in continuous mode, the “0” on the additional label must be covered with the enclosed “1” sticker.
  • Apply stickers to the second enclosed additional label in the same way and affix it to the luminaire so that it is easily visible from the outside.
  • The additional enclosed voltage/ frequency label (220-240 V y 50/60 Hz) must also be affixed to the luminaire so that it is visible from the outside.

Notice prior to installation:

  • The accumulator is supplied partially charged. In order to avoid an early discharge of the accumulator by the charging unit, a plug connector has been unplugged from the accumulator. Before setting the luminaire into operation this plug needs to be plugged-in again

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Installation

  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Undo the screws and lift off the luminaire top. Disconnect the earth conductor connection from the plug connection.
  • Lead the mains supply cable through the cable entry of the luminaire base.
  • In outdoor areas, the light emission may only be directed downwards.
  • Note position of application of the luminaire “arrow down”.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied. Make the earth conductor connection and the electrical connection.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • When the luminaire is operated with an external switch (switched maintained light), the jumper wire is to be connected to terminal L’ and the factory-set jumper between L’ and L is to be removed.
  • If the luminaire is operated in standby mode, the factory-set jumper is to be removedBEGA-24098-Wall-Luminaire-with-Emergency-Lighting-Function-fig-3
  • Make earth conductor connection between luminaire top and luminaire base.
  • In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
  • Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
  • Make sure that gasket is positioned correctly. Replace the luminaire top and tighten the screws evenly.

Initial set-up

  • The emergency lighting device will commence charging the battery for 24 hours (initial charge), once the luminaire is installed and mains power is connected.
  • The recharge of a newly connected rechargeable battery will similarly take max. 24 hours.
  • Emergency lighting operation will automatically commence directly after initial set-up (and therefore also after each battery change or after a charging error reset) to optimise battery capacity, which may have suffered due to extended storage times.
  • For more information about technical data, storage, service life, etc. of the emergency lighting device see www.lampec-swiss.ch.

Status indication

  • System status is indicated by a bi-colour LED

Testing

  • This luminaire has a self-test function to comply with statutory requirements.
  • Self-testing will be carried out approx. every 8 days (function test) and four times a year (continuous operation test).
  • The microprocessor-controlled function test will be carried out for 2 minutes every 8 days.
  • A complete continuous operation test is carried out four times a year to check battery output.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.
  • Replacing the LED module
  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Temperature switch 61 001 248
  • LED power supply unit DEV-0293/350
  • Heating resistor 61 001 627
  • Emergency lighting module 61 002 045
  • Rechargeable battery 61 002 046
  • LED module 3000 K LED-0731/830
  • LED module 4000 K LED-0731/840
  • Reflector 76 001 834
  • Gasket 83 001 036

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · [email protected] · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals