BEGA 51 215.5 Ceiling Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 51 215.5 Ceiling Luminaire
Product Information
The product is a luminaire that requires installation and operation in accordance with national safety regulations. It is recommended to have a qualified electrician perform the installation and commissioning to ensure safety. The manufacturer does not accept liability for damage caused by improper use or installation. Any modifications made to the luminaire should be done by the person responsible for them, who will be considered the manufacturer.
Safety
The luminaire is subject to national safety regulations. Installation and
commissioning should only be carried out by a qualified electrician. The
manufacturer is not liable for damage caused by improper use or installation.
Overvoltage Protection
The electronic components in the luminaire are protected against overvoltage
according to DIN EN 61547. For additional protection against transients, it is
recommended to use separate overvoltage protection components, which can be
found on the manufacturer’s website at www.bega.com.
Lamp Information
The luminaire uses an LED lamp module with a connected wattage of 31.6 W. The
luminaire itself has a connected wattage of 36.5 W.
The rated temperature is 25°C, and the ambient temperature should not exceed
30°C.
LED Module Information
The LED module has the designation LED-0800/930 and has a colour temperature
of 3000 K. The colour rendering index (CRI) is greater than 90. The module has
a luminous flux of 4220 lm, while the luminaire has a luminous flux of 2241
lm. The luminaire’s luminous efficiency is 61.4 lm/W.
Installation
LEDs are high-quality electronic components, so it is important to avoid
touching the light output opening directly during installation or relamping.
Replacing the LED Module
The designation of the LED module can be found on a label in the luminaire.
When replacing the module, make sure that the light color and light output of
the replacement module match those of the original module. Qualified personnel
should use standard tools to replace the module and ensure that the system is
disconnected from the mains.
Ceiling luminaire · downlight with zoom optics for indoor use
Instructions for use
Application
Ceiling luminaire downlight · Indoor luminaire with focusable zoom optics.
Adjustable light distribution.
To change the light distribution, optical filters are available as accessory
parts.
Changing the half beam angle between 14° and 60° by twisting the lens unit.
Product description
- Cast aluminium luminaire housing, finish Colour velvet black,
- 2 mounting holes ø 4.5 mm
- Distance apart 112 mm
- Optical lens made of silicate glass
- Adjustable metal adapter ring with PMMA lens combination and integrated optical filter. Connecting terminals 2.5@
- Earth conductor connection
- LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-276 V
- During DC operation the LED power is reduced to 15 %
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- CE – Conformity mark
- Weight: 1.4 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
- Module connected wattage 31.6 W
- Luminaire connected wattage 36.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 30 °C
51 215.5 K3
- Module designation LED-0800/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 4220 lm
- Luminaire luminous flux 2241 lm
- Luminaire luminous efficiency 61,4 lm / W
Light technique
- Adjustable light distribution
- Half beam angle 15° – 55°
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Remove mounting plate from the luminaire housing.
Unplug the earth conductor connection (plug contact).
Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface,
it is mandatory to make sure that the mounting surface is connected conductive
to the earth conductor of the luminaire!
Lead the power connecting cable through the mounting plate.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Establish the earth conductor connection on the earthing screw (1) of the
mounting plate. Establish the earth conductor connection to the luminaire
housing (plug contact).
Push silicone hoses over connecting wires and make the electrical connection
at the terminal marked (L) and (N).
The two connecting terminals marked DA, DA are provided for digital control
purposes.
If these terminals are not assigned, the luminaire will work with full light
output.
IMPORTANT:
To ensure secure connection, the luminaire housing must be positioned
precisely in relation to the mounting plate.
Make sure that the vertical bar inside the luminaire housing is positioned
precisely in the area of the mounting hole on the long bar of the mounting
plate.
Press the luminaire housing firmly against the mounting plate and turn it
clockwise firmly against the stop.
The desired half beam angle of the luminaire can be set by turning the
adjustment ring with the marked cam.
The range of the half beam angles on the trim ring includes a tolerance of ±
2.5°.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light color and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified personnel using standard tools.
Disconnect the system from the mains.
Grasp the internal adapter ring with optical filter by one of its metal tabs
and pull it out of the recess in the luminaire housing against the magnetic
resistance.
Loosen the trim ring counter-clockwise from the housing of the zoom downlight.
Remove the reflector with optical lens unit from the housing.
Remove the black insulating foil from the LED module.
Remove the LED module. Install the replacement LED module.
Apply the replacement insulating foil to the LED module.
Please follow the installation instructions for the new LED module.
IMPORTANT: Before inserting the reflector into the luminaire housing,
make sure that the polycarbonate sign (>ASA+PC<) embossed in the lens holder
points in the direction of the LED connection terminal.
Guide the recesses of the lens holder over the two bolts and insert the
reflector.
Place the trim ring with the scale on the luminaire housing. Make sure that
the 15° position is correctly positioned in relation to the embossed
polycarbonate sign (>ASA+PC<) in the lens holder.
Insert the trim ring into the recess of the luminaire housing (note 15°
position) and tighten clockwise.
Set the desired half beam angle of the luminaire by turning the marked
adjustment ring cam. Reinsert the adapter ring with optical filter into the
housing of the zoom downlight.
The magnetic housing recess allows the adapter ring to lock precisely into
place.
If the disc combination of the adapter ring with optical filter is defective,
it must be replaced.
Accessories · Optical filters
- 13 324 flat beam
- 13 326 symmetrical, diffuse
- 13 325 asymmetrical
For the accessories a separate instructions for use can be provided upon request.
Spares
- Insulating foil 16 006 564 B1
- Trim ring 20 000 088 B7
- LED power supply unit DEV-0144/900i
- LED module 3000 K LED-0800/930
- Adapter ring with optical filter 75 005 189
- Lens unit 75 005 679
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>