3onedata IES2305 Unmanaged Industrial Ethernet Switch Installation Guide

June 1, 2024
3onedata

3onedata IES2305 Unmanaged Industrial Ethernet Switch

3onedata-IES2305-Unmanaged-Industrial-Ethernet-Switch-product-
image

Specifications:

  • Model: IES2305 Series
  • Type: Unmanaged Industrial Ethernet Switch
  • Ports: 5-port Gigabit
  • Power Supply: Model I, VI, VIII – 12~48VDC | Model III, IV, V – 48VDC

Product Overview:
The IES2305 Series are 5-port Gigabit unmanaged industrial Ethernet switches. There are different models available with varying port configurations and power supply options.

Panel Design:
Front view:

  • Model I, II: Gigabit Copper Ports
  • Model III: PoE Copper Ports, Gigabit Copper Port

Mounting Dimension:
Unit: mm

Mounting Instructions:

  1. Check if the DIN-Rail mounting kit is installed firmly.
  2. Insert the bottom of DIN-Rail mounting kit into DIN-Rail, then insert the top.
  3. Check and confirm the product is firmly installed on DIN-Rail.

Disassembling DIN-Rail:

  1. Power off device.
  2. Lift the device slightly, shift out the top of DIN-Rail mounting kit, then shift out the bottom.

Power Supply Connection:
For 12~48VDC power supply models, ensure correct polarity with the provided terminals. For 48VDC power supply models supporting PoE, ensure anti-reverse connection function is utilized.

FAQ:

  • Q: What should I do if any items in the package are damaged or lost?
    A: If any items are damaged or lost, please contact our company or dealers for assistance, and we will resolve the issue promptly.

Address: 3/B, Zone 1, Baiwangxin High Technology Industrial Park, Xili, Nanshan District, Shenzhen
Website: www.3onedata.com
Tel: +86 0755-26702688
Fax:   +86 0755-26703485

Package Checklist
Please check whether the package and accessories are intact while using the switch for the first time.

  1. Switch (with terminal
  2. DIN-Rail mounting block) attachment
  3. Certification
  4. Warranty card

If any of these items are damaged or lost, please contact our company or dealers, we will solve it ASAP.

Product Overview

This series are 5-port Gigabit unmanaged industrial Ethernet switches. For convenience, the products of this series adopt the following number on the left in this guide, please affirm the number of your product.

  • Model I. IES2305-5GT-P48 (5 Gigabit copper ports + 1 12-48VDC power supply)
  • Model II. IES2305-5GT-P220 (5 Gigabit copper ports + 1 100-240VAC power supply)
  • Model III. IES2305-4GP1GT-P48 (4 100M PoE copper ports + 1 Gigabit copper port + 1 48VDC power supply)
  • Model IV. IES2305-4GP1GS-P48 (4 Gigabit PoE copper ports + 1 Gigabit SFP + 1 48VDC power supply)
  • Model V.IES2305-4GP1GF-P48 (4 Gigabit PoE copper ports + 1 Gigabit fiber port + 1 48VDC power supply)
  • Model VI. IES2305-4GT1GS-P48 (4 Gigabit copper ports + 1 Gigabit SFP + 1 12~48VDC power supply)|
  • Model VII. IES2305-4GT1GS-P220 (4 Gigabit copper ports + 1 Gigabit SFP + 1 100~240VAC power supply)
  • Model VIII. IES2305-4GT1GF-P48 (4 Gigabit copper ports + 1 Gigabit fiber port + 1 12-48VDC power supply)
  • Model IX. IES2305-4GT1GF-P220 (4 Gigabit copper ports + 1 Gigabit fiber port + 1 100-240VAC power supply)

Panel Design

Front view

3onedata-IES2305-Unmanaged-Industrial-Ethernet-
Switch-\(1\)

3onedata-IES2305-Unmanaged-Industrial-Ethernet-
Switch-\(2\)

Rear view, Bottom view and Top view

3onedata-IES2305-Unmanaged-Industrial-Ethernet-
Switch-\(3\)

  1. Power supply indicator
  2. Gigabit Copper Port
  3. Interface connection indicator
  4. PoE indicator
  5. Gigabit PoE copper port
  6. Gigabit SFP
  7. Gigabit fiber port
  8. DIN-Rail mounting kit
  9. Power input terminal block
  10. DIP switch
  11. Grounding screw

Mounting Dimension
Unit: mm

3onedata-IES2305-Unmanaged-Industrial-Ethernet-
Switch-\(4\)

DIN-Rail Mounting

The product adopts 35mm standard DIN-Rail mounting which is suitable for most industrial scenes, mounting steps as follows:

3onedata-IES2305-Unmanaged-Industrial-Ethernet-
Switch-\(5\)

  • Step 1 Check if the DIN-Rail mounting kit is installed firmly.
  • Step 2  Insert the bottom of DIN-Rail mounting kit (one side with spring support) into DIN-Rail, and then insert the top into DIN-Rail.

Tips:
Insert a little to the bottom, lift upward and then insert to the top.

  • Step 3  Check and confirm the product is firmly installed on DIN-Rail, then mounting ends.

Disassembling DIN-Rail

  • Step 1 Power off device.
  • Step 2  After lifting the device upward slightly, first shift out the top of DIN-Rail mounting kit, and then shift out the bottom of DIN-Rail, disassembling ends.

Don’t place or install the device in area near water or moist, keep the relative humidity of the device surrounding between 5%~95% without condensation. Before power on, first confirm the supported power supply specification to avoid over-voltage damaging the device. The device surface temperature is high after running; please don’t directly contact to avoid scalding.

Power Supply Connection

12~48VDC power supply

Model I, VI, VIII devices of this series support DC power input, and provide 3-pin terminals with a spacing of 7.62 mm. The power supply has non-polarity function. Voltage range:  12~48VDC. The pin definitions of power supply are shown as follows:

PIN 1 2 3
Definition V+ FG V-

48VDC power supply
Model III, IV, V devices of this series support DC power input, and provide 3-pin terminals with a spacing of 7.62 mm. The power  supply has anti-reverse connection function. Support 48V PoE, power range: 48VDC (44~55VDC). The pin definitions of power supply are shown as follows:

PIN 1 2 3
Definition V+ FG V-

AC power supply
Model II, VII, IX devices of this series support AC power input, and provide 3-pin terminals with a spacing of 7.62 mm. Power supply value range is: 220VAC (100~240VAC). The pin definitions of power supply are shown as follows:

PIN 1 2 3
Definition L FG N

Power ON operation: First insert the power supply terminal block into the device power supply interface, and then plug the power supply plug contact and power on.
Power OFF operation: First, remove the power plug, and then remove the wiring section of terminal block. Please pay attention to the above operation sequence.

DIP Switch Settings

This series provide 4-pin DIP switch for function setting, where “ON” is the enabled end. DIP switches definition as follows:

DIP Definition Operation
1 Jumbo frame Set the DIP to ON to enable jumbo frame function
2 Flow Control Set the DIP to ON to enable flow control function
3 One-key VLAN Set the DIP to ON to enable VLAN function. D Model I-Model

III: copper port 1 is interconnected with other interfaces, and other ports except copper port 1 are isolated from each other. D Model IV- Model IX: fiber port (5 ports) port is interconnected with other interfaces, and other ports except fiber ports are isolated from each other.
4| Port 100M| Set the DIP to ON, port rate would be forced to be in 100M

Checking LED Indicator

The device provides LED indicators to monitor the device working status with a comprehensive simplified troubleshooting; the detailed status of each LED is described in the table as below:

LED Indicate Description
PWR ON PWR      is  connected       and
running normally
--- --- ---
OFF PWR     is     disconnected       and running abnormally
PoE (G1-G4) ON POE port is powering other devices normally
OFF POE is disabled or disconnected
Link/ACT (G1-G5) ON Port has established valid network connection
Blinking Port is receiving/ transmitting data
OFF Port hasn’t established valid network connection

Specification

Panel|
---|---
Gigabit fiber port| 1000Base-FX, optional SC/ST/FC
Gigabit SFP| 1000Base-X SFP
Gigabit Copper Port| 10/100/1000 Base-T(X) self-adapting RJ45 port, half/full duplex self-adaption or forced working mode, support MDI/ MDI-X self-adaption
Gigabit     POE      copper port| 10/100/1000Base-T(X) RJ45, automatic flow control, full/half duplex mode, MDI/ MDI-X auto tunning, POE port, output power of 15W or 30W.
POE pin| V+, V+, V-, V- are corresponding to 1, 2, 3, 6.
Indicator| Power indicator, PoE indicator, interface indicator
Power supply|
Input power supply| D 12~48VDC power supply, support non-polarity D 48VDC power supply: 44~55VDC, support anti-reverse connection D 220VAC power supply: 100~240VAC
---|---
Access terminal block| 3-pin 7.62mm pitch terminal blocks
Switch Property|
Backplane bandwidth| 9.125G
MAC address| 2K
Power consumption|
Model III, Model IV| No-load: ≤1.4W@48VDC Full-load: ≤100.6W@48VDC
Working Environment|
Working temperature| -40〜75℃
Storage temperature| -40〜85℃
Working humidity| 5%〜95% (no condensation)
Protection grade| IP40 (metal shell)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

3onedata User Manuals

Related Manuals