3onedata IES2305 Unmanaged Industrial Ethernet Switch
Specifications:
- Model: IES2305 Series
- Type: Unmanaged Industrial Ethernet Switch
- Ports: 5-port Gigabit
- Power Supply: Model I, VI, VIII – 12~48VDC | Model III, IV, V – 48VDC
Product Overview:
The IES2305 Series are 5-port Gigabit unmanaged industrial Ethernet
switches. There are different models available with varying port
configurations and power supply options.
Panel Design:
Front view:
- Model I, II: Gigabit Copper Ports
- Model III: PoE Copper Ports, Gigabit Copper Port
Mounting Dimension:
Unit: mm
Mounting Instructions:
- Check if the DIN-Rail mounting kit is installed firmly.
- Insert the bottom of DIN-Rail mounting kit into DIN-Rail, then insert the top.
- Check and confirm the product is firmly installed on DIN-Rail.
Disassembling DIN-Rail:
- Power off device.
- Lift the device slightly, shift out the top of DIN-Rail mounting kit, then shift out the bottom.
Power Supply Connection:
For 12~48VDC power supply models, ensure correct polarity with the provided
terminals. For 48VDC power supply models supporting PoE, ensure anti-reverse
connection function is utilized.
FAQ:
- Q: What should I do if any items in the package are damaged or lost?
A: If any items are damaged or lost, please contact our company or dealers for assistance, and we will resolve the issue promptly.
Address: 3/B, Zone 1, Baiwangxin High Technology Industrial Park, Xili,
Nanshan District, Shenzhen
Website: www.3onedata.com
Tel: +86 0755-26702688
Fax: +86 0755-26703485
Package Checklist
Please check whether the package and accessories are intact while using the
switch for the first time.
- Switch (with terminal
- DIN-Rail mounting block) attachment
- Certification
- Warranty card
If any of these items are damaged or lost, please contact our company or dealers, we will solve it ASAP.
Product Overview
This series are 5-port Gigabit unmanaged industrial Ethernet switches. For convenience, the products of this series adopt the following number on the left in this guide, please affirm the number of your product.
- Model I. IES2305-5GT-P48 (5 Gigabit copper ports + 1 12-48VDC power supply)
- Model II. IES2305-5GT-P220 (5 Gigabit copper ports + 1 100-240VAC power supply)
- Model III. IES2305-4GP1GT-P48 (4 100M PoE copper ports + 1 Gigabit copper port + 1 48VDC power supply)
- Model IV. IES2305-4GP1GS-P48 (4 Gigabit PoE copper ports + 1 Gigabit SFP + 1 48VDC power supply)
- Model V.IES2305-4GP1GF-P48 (4 Gigabit PoE copper ports + 1 Gigabit fiber port + 1 48VDC power supply)
- Model VI. IES2305-4GT1GS-P48 (4 Gigabit copper ports + 1 Gigabit SFP + 1 12~48VDC power supply)|
- Model VII. IES2305-4GT1GS-P220 (4 Gigabit copper ports + 1 Gigabit SFP + 1 100~240VAC power supply)
- Model VIII. IES2305-4GT1GF-P48 (4 Gigabit copper ports + 1 Gigabit fiber port + 1 12-48VDC power supply)
- Model IX. IES2305-4GT1GF-P220 (4 Gigabit copper ports + 1 Gigabit fiber port + 1 100-240VAC power supply)
Panel Design
Front view
Rear view, Bottom view and Top view
- Power supply indicator
- Gigabit Copper Port
- Interface connection indicator
- PoE indicator
- Gigabit PoE copper port
- Gigabit SFP
- Gigabit fiber port
- DIN-Rail mounting kit
- Power input terminal block
- DIP switch
- Grounding screw
Mounting Dimension
Unit: mm
DIN-Rail Mounting
The product adopts 35mm standard DIN-Rail mounting which is suitable for most industrial scenes, mounting steps as follows:
- Step 1 Check if the DIN-Rail mounting kit is installed firmly.
- Step 2 Insert the bottom of DIN-Rail mounting kit (one side with spring support) into DIN-Rail, and then insert the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert to the top.
- Step 3 Check and confirm the product is firmly installed on DIN-Rail, then mounting ends.
Disassembling DIN-Rail
- Step 1 Power off device.
- Step 2 After lifting the device upward slightly, first shift out the top of DIN-Rail mounting kit, and then shift out the bottom of DIN-Rail, disassembling ends.
Don’t place or install the device in area near water or moist, keep the relative humidity of the device surrounding between 5%~95% without condensation. Before power on, first confirm the supported power supply specification to avoid over-voltage damaging the device. The device surface temperature is high after running; please don’t directly contact to avoid scalding.
Power Supply Connection
12~48VDC power supply
Model I, VI, VIII devices of this series support DC power input, and provide 3-pin terminals with a spacing of 7.62 mm. The power supply has non-polarity function. Voltage range: 12~48VDC. The pin definitions of power supply are shown as follows:
PIN | 1 | 2 | 3 |
---|---|---|---|
Definition | V+ | FG | V- |
48VDC power supply
Model III, IV, V devices of this series support DC power input, and provide
3-pin terminals with a spacing of 7.62 mm. The power supply has anti-reverse
connection function. Support 48V PoE, power range: 48VDC (44~55VDC). The pin
definitions of power supply are shown as follows:
PIN | 1 | 2 | 3 |
---|---|---|---|
Definition | V+ | FG | V- |
AC power supply
Model II, VII, IX devices of this series support AC power input, and
provide 3-pin terminals with a spacing of 7.62 mm. Power supply value range
is: 220VAC (100~240VAC). The pin definitions of power supply are shown as
follows:
PIN | 1 | 2 | 3 |
---|---|---|---|
Definition | L | FG | N |
Power ON operation: First insert the power supply terminal block into the
device power supply interface, and then plug the power supply plug contact and
power on.
Power OFF operation: First, remove the power plug, and then remove the
wiring section of terminal block. Please pay attention to the above operation
sequence.
DIP Switch Settings
This series provide 4-pin DIP switch for function setting, where “ON” is the enabled end. DIP switches definition as follows:
DIP | Definition | Operation |
---|---|---|
1 | Jumbo frame | Set the DIP to ON to enable jumbo frame function |
2 | Flow Control | Set the DIP to ON to enable flow control function |
3 | One-key VLAN | Set the DIP to ON to enable VLAN function. D Model I-Model |
III: copper port 1 is interconnected with other interfaces, and other ports
except copper port 1 are isolated from each other. D Model IV- Model IX: fiber
port (5 ports) port is interconnected with other interfaces, and other ports
except fiber ports are isolated from each other.
4| Port 100M| Set the DIP to ON, port rate would be forced to be in 100M
Checking LED Indicator
The device provides LED indicators to monitor the device working status with a comprehensive simplified troubleshooting; the detailed status of each LED is described in the table as below:
LED | Indicate | Description |
---|---|---|
PWR | ON | PWR is connected and |
running normally | ||
--- | --- | --- |
OFF | PWR is disconnected and running abnormally | |
PoE (G1-G4) | ON | POE port is powering other devices normally |
OFF | POE is disabled or disconnected | |
Link/ACT (G1-G5) | ON | Port has established valid network connection |
Blinking | Port is receiving/ transmitting data | |
OFF | Port hasn’t established valid network connection |
Specification
Panel|
---|---
Gigabit fiber port| 1000Base-FX, optional SC/ST/FC
Gigabit SFP| 1000Base-X SFP
Gigabit Copper Port| 10/100/1000 Base-T(X) self-adapting RJ45 port, half/full
duplex self-adaption or forced working mode, support MDI/ MDI-X self-adaption
Gigabit POE copper port| 10/100/1000Base-T(X) RJ45, automatic flow
control, full/half duplex mode, MDI/ MDI-X auto tunning, POE port, output
power of 15W or 30W.
POE pin| V+, V+, V-, V- are corresponding to 1, 2, 3, 6.
Indicator| Power indicator, PoE indicator, interface indicator
Power supply|
Input power supply| D 12~48VDC power supply, support non-polarity D 48VDC
power supply: 44~55VDC, support anti-reverse connection D 220VAC power supply:
100~240VAC
---|---
Access terminal block| 3-pin 7.62mm pitch terminal blocks
Switch Property|
Backplane bandwidth| 9.125G
MAC address| 2K
Power consumption|
Model III, Model IV| No-load: ≤1.4W@48VDC Full-load: ≤100.6W@48VDC
Working Environment|
Working temperature| -40〜75℃
Storage temperature| -40〜85℃
Working humidity| 5%〜95% (no condensation)
Protection grade| IP40 (metal shell)