mxion 30B Digital Booster User Manual

June 3, 2024
mXion

mxion EKW EKWs Switch Decoder

mxion EKW EKWs Switch Decoder PRODUCT

Introduction

Dear customer, we strongly recommend that you read these manuals and the warning notes thoroughly before installing and operating your device. The device is not a toy (15+).
NOTE: Make sure that the outputs are set to appropriate value before hooking up any other device. We can’t be responsible For any damage if this is disregarded.

General information

We recommend studying this manual thoroughly before installing and operating your new device.
NOTE: Some functions are only available with the latest firmware. Please make sure that your device is programmed with the latest firmware.
Set your current top to 2 – 3 Amps more than that you usually use.

Summary of Functions

  • Booster for all protocols
  • 25A (30A peak) power amplifiers
  • Operating voltage 14 – 24 V
  • (suggested our PS4 or PS5 supply)
  • ONLY DC VOLTAGE SWITCHING SUPPLY! DCC, Märklin-Motorola, Selectin, mfx, etc. LGB® MTS support also pulse driver Temperature-controlled fan
  • RailCom® detection gab can be activated Internal temperature and current monitor Automatic reinit if short failures
  • Big LCD display with menu and values Automatic restart after failure possible Monitoring all values at the display External power supply with each DC power supply with an voltage up to 24V Usable for all tracks with matching power CDE, XpressNet®, LocoNet, S88N or from track
  • LocoNet(B) input possible
  • Sturdy screw terminals
  • Multilingual, lang. adjustable via the display
  • Can be used as control station with Roco® Multimaus®

Scope of supply

  • Manual
  • mXion 30B Digital-Booster

Hook Up

Install your device in compliance with the connecting diagrams in this manual. The device is protected against shorts and excessive loads. However, in case of a connection error e.g. a short this safety feature can’t work and the device will be destroyed subsequently.
Make sure that there is no short circuit caused by the mounting screws or metal.
NOTE: Please note the CV basic settings in the delivery state.

Connectors

Make sure you have sufficiently large cross section depending on the power output. Pay attention to the separation, if you have several operate booster or central or booster/central mixture. You can also use the booster alone to supply use the plant (e.g. for weak control centers, control panels without output stage or Roco® Multimaus®). With the Roco® Multimaus® the 30B becomes the headquarters! Never close several sources at the same time. Pay attention to the correct polarity the input voltage – danger of destruction! The voltage of the connected power supply plus on the display. You can at the CDE input also directly track voltage of the previous section connect (track to C & D). mxion EKW EKWs Switch Decoder 01Always use only one feed option of the booster (e.g, signal input CDE OR signal input OR LocoNet-Booster signal input OR S88N OR signal input XpressNet (Booster). If your control station is not one of the above listed interfaces you can either use our B-Bus/CDE/XpressNet converter (item no. 0017) or directly the track output of your central station to the inputs of C and D (see picture downsite).mxion EKW EKWs Switch Decoder 02

Connection to central units

The connection to control panels is simple, one option is always the track exit of the control panel connect directly to C and D of the CDE connector. Our CDE adapter (0017) is universally usable.
CDE control units can be connected directly

Connection to MZSpro/Massoth/Z21/B-Bus

mxion EKW EKWs Switch Decoder 03

Connection to PIKO®-G Central Units

With our bus distributor (Item No. 0012) you can additional control units connected to the control panel become. mxion EKW EKWs Switch Decoder
04

Connection to Eco’s/CS Central Units

This type of central unit can directly connect to the CDE:

  • C = Date/Data
  • D = Masse/GND
  • E = ShDCC
  • Short time
    Tripping time when the current limit exceeded

  • Current limit
    Current limit as the maximum current flow

  • Stage shorts
    Increased sensitivity in the event of a direct short circuit

  • Sampling
    Sampling rate for step short-circuit detection

  • RailCom BiDi
    Generation of the blanking interval for RailCom

  • Switchover
    Detection time for the input signal. Shows the Booster in operation “No signal” or there is Dropouts, increase this time

  • Short restart
    After short circuit restart after this time. Ideal connection via C&D without E-line (thus the control center does not switch off in
    the event of a short circuit)

  • Language
    Multiple languages available

  • Help
    Display of contact details for assistance

Product description

The mXion 30B ist the powerful booster. He can be charged up to 30A tip. There it is possible to use all protocols (DCC, Selectin, Märklin-Motorola or mixed operation).
Furthermore, there is the possibility of the booster over the CDE interface, XpressNet® as well as S88N too operate. CDE and XpressNet® can with feedback work. Furthermore, there is the possibility of easy the track of the head office or the previous section to connect to CDE. Here then C and D must be connected to the track. Sections between boosters/control have always the same polarity and disconnected on both sides. All values (voltage, current, temperature, load). In addition, the output stage can be switched off „Emergency Stop“ when the switch is pressed. If the knob is turned, you will find the menu with the corresponding sub-items. Press through within the menu can be settings of the values (e.g. current limit) are made. Actuate do not press the button for 3-4 seconds, it jumps back to the overview. In addition, all languages can be found in the menu to be chosen.
NOTE: The booster offers a possibility independently in case of error after adjustable time to turn on again, ideal for several booster sections.
You do not have a control station?
Transform the booster into a full-fledged control center with a Roco®-Multimaus!
For more XpressNet® devices (e.g. more Multimaus) or Multimaus WLAN with our XP-Z21 plug it is recommended to use our XpressNet® distributor (important)!mxion EKW EKWs Switch Decoder 05

Technical data

  • Power supply:  14 – 24V DC Only use DC-Trafos!
  • Current: 30mA, switched off booster
  • Maximum current:
    • 30 Amps. for short time
    • 25 Amps all time
  • Temperature range: -40 up to 110°C
  • Dimensions LBH (cm): 15146

NOTE: In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of condensed water. During operation is sufficient to prevent condensed water.

Warranty, Service, Support

micron-dynamics warrants this product against defects in materials and workmanship for one year from the original date of purchase. Other countries might have different legal warranty situations. Normal wear and tear, consumer modifications as well as improper use or installation are not covered. Peripheral component damage is not covered by this warranty. Valid warrants claims will be serviced without charge within the warranty period. For warranty service please return the product to the manufacturer. Return shipping charges are not covered by micron-dynamics. Please include your proof of purchase with the returned good. Please check our website for up to date brochures, product information, documentation and software updates. Software updates you can do with our updater or you can send us the product, we update for you free.
Errors and changes excepted.
Hotline
For technical support and schematics for application examples contact:
micron-dynamics
info@micron-dynamics.de
service@micron-dynamics.de
www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

mXion User Manuals

Related Manuals