mxion LSS-RhB User Manual

June 3, 2024
mXion

mxion LSS-RhB product

mxion LSS-RhB product

Introduction

Dear customer, we strongly recommend that you read these manuals and the warning notes thoroughly before installing and operating your device. The device is not a toy (15+).
NOTE: Make sure that the outputs are set to appropriate value before hooking up any other device. We can’t be responsible For any damage if this is disregarded.

General information

We recommend studying this manual thoroughly before installing and operating your new device.
NOTE: Some functions are only available with the latest firmware. Please make sure that your device is programmed with the latest firmware.

Summary of Functions

  • DC/AC/DCC operation
  • Compatible NMRA-DCC module
  • Real light signals
  • Defined start switching
  • Outputs invertible
  • Automatic switch back functions
  • Function outputs dimmable
  • Reset function for all CV values
  • Easy function mapping
  • addresses, 2048 switch addresses
  • Multiple programming options
  • (Bitwise, CV, POM accessories decoder, register) Needs no programming load

Reach of wireless depends on house WLan

Scope of supply

  • Manual
  • mXion LSS-RhB

Hook-Up

Install your device in compliance with the connecting diagrams in this manual. The device is protected against shorts and excessive loads. However, in case of a connection error e.g. a short this safety feature can’t work and the device will be destroyed subsequently.
Make sure that there is no short circuit caused by the mounting screws or metal.

Connectors

  • This typical switch signal is for everyone RhB, swiss train company. It can due to the small dimensions optimally in the station area be accommodated. The signal works digitally as well as analog. Simply close the 2 cables to the track or a DC voltage source e.g. EPL®.
  • Weatherproof : Cover the PCB with „Plastik70“.

Product description

The mXion LSS-RhB is a modern light signal or dwarf signal of the swiss railways (e.g. also the RhB). Here these light signals are large quantities of routes, switches and used next to the railway line for shunting as well as free or hold. Exemplary true-to-scale RhB dwarf signal with integrated decoder
can prototypically “stop”, “drive” and also “drive with caution”.
The integrated decoder for analog and digital operation allows all images of the signal
to be given in an exemplary way. In addition will be a series of switching and additional functions allows, which are separately activated (e.g. automatic switching back to timing when a train has passed).

Programming lock

To prevent accidental programming to prevent CV 15/16 one programming lock. Only if CV 15 = CV 16 is a programming possible. Changing CV 16 changes automatically also CV 15. With CV 7 = 16 can the programming lock reset.
STANDARD VALUE CV 15/16 = 165

Programming options

This decoder supports the following programming types: bitwise, POM and CV read & write and register-mode and programming switch.
There will be no extra load for programming.
In POM (programming on main track) the programming lock is also supported. The decoder can also be on the main track programmed without the other decoder to be influenced. Thus, when programming the decoder can not be removed.
NOTE: To use POM without others decoder must affect your digital center POM to specific decoder addresses (e.g. Massoth® control panels)

Programming binary values

Some CV’s (e.g. 29) consist of so-called binary values. The means that several settings in a value. Each function has a bit position and a value. For programming such a CV must have all the significances can be added. A disabled function has always the value 0.
EXAMPLE: You want 28 drive steps and long loco address. To do this, you must set the value in CV 29 2 + 32 = 34 programmed.

Programming switch address

Switch addresses consist of 2 values.
For addresses < 256 the value can be directly in address low. The high address is 0. If the address is > 255 this is as follows (for example address 2000):

  • 2000 / 256 = 7,81, address high is 7
  • 2000 – (7 x 256) = 208, address low is then 208.

Reset functions

The decoder can be reset via CV 7. Various areas can be used for this purpose.
Write with the following values:

  • 11 (basic functions)
  • 16 (programming lock CV 15/16)
  • 33 (switch outputs)

CV-Table

S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable

CV Description S L/S Range Note
7 Software version read only (10 = 1.1)
7 Decoder reset functions
3 ranges available 11

16
33| basic settings (CV 1,11-13,17-19,29-119) programming lock (CV 15/16)
switch outputs (from CV 120)
8| Manufacturer ID| 160| | –| read only
7+8| Register programming mode
Reg8 = CV-Address Reg7 = CV-Value| | | | CV 7/8 don’t changes his real value
CV 8 write first with cv-number, then CV 7 write with value or read (e.g.: CV 49 should have 3)
è CV 8 = 49, CV 7 = 3 writing
15| Programming lock (key)| 215| LS| 0 – 255| to lock only change this value
16| Programming lock (lock)| 215| LS| 0 – 255| changes in CV 16 will change CV 15
48| Switch address calculation| 0| S| 0/1| 0 = Switch address like norm
1 = Switch address like Roco, Fleischmann
49| mXion configuration| 0| S| | bitwise programming
Bit| Value| OFF (Value 0)| ON
0| 1| stop/drive normal function| stop/drive invert function
4| 16| stop/caution normal function| stop/caution invert function
6| 64| not save position| save position
118| Automatic switch back function to last state| 0| S| 0 – 255| 0 = off
1 – 255 = time base 0,25 sec. each Value
120| Stop/go address low| 0| W| 1 – 2048| Switching address, if address is less than 256 simply CV121 = desired address!
121| Stop/go address high| 1| W
122| dimming value| 100| W| 1 – 100| Dimming value in % (1% approx. 0.2 V)
125| Stop/go w. caution address low| 0| W| 1 – 2048| Switching address, if address is less than 256 simply CV126 = desired address!
126| Stop/go w. caution address high| 2| W
127| dimming value| 100| W| 1 – 100| Dimming value in % (1% approx. 0.2 V)

Technical data

  • Power supply: 7-27V DC/DCC
    5-18V AC

  • Current: 5mA (with out functions)

  • Maximum function current:

    • LSS        0.1 Amps.
  • Maximum current: 0.2 Amps.

  • Temperature range: -20 up to 85°C

  • Dimensions LBH (cm):  2.52.71

NOTE: In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of condensed water. During operation is sufficient to prevent condensed water.

Warranty, Service, Support

micron-dynamics warrants this product against defects in materials and workmanship for one year from the original date of purchase. Other countries might have different legal warranty situations. Normal wear and tear, consumer modifications as well as improper use or installation are not covered. Peripheral component damage is not covered by this warranty. Valid warrants claims will be serviced without charge within the warranty period. For warranty service please return the product to the manufacturer. Return shipping charges are not covered by micron-dynamics. Please include your proof of purchase with the returned good. Please check our website for up to date brochures, product information, documentation and software updates. Software updates you can do with our updater or you can send us the product, we update for you free.
Errors and changes excepted.
Hotline
For technical support and schematics for application examples contact:
micron-dynamics
[email protected]
[email protected]
www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

mXion User Manuals

Related Manuals