mxion LSS-RhB User Manual
- June 3, 2024
- mXion
Table of Contents
mxion LSS-RhB product
Introduction
Dear customer, we strongly recommend that you read these manuals and the
warning notes thoroughly before installing and operating your device. The
device is not a toy (15+).
NOTE: Make sure that the outputs are set to appropriate value before
hooking up any other device. We can’t be responsible For any damage if this is
disregarded.
General information
We recommend studying this manual thoroughly before installing and operating
your new device.
NOTE: Some functions are only available with the latest firmware. Please
make sure that your device is programmed with the latest firmware.
Summary of Functions
- DC/AC/DCC operation
- Compatible NMRA-DCC module
- Real light signals
- Defined start switching
- Outputs invertible
- Automatic switch back functions
- Function outputs dimmable
- Reset function for all CV values
- Easy function mapping
- addresses, 2048 switch addresses
- Multiple programming options
- (Bitwise, CV, POM accessories decoder, register) Needs no programming load
Reach of wireless depends on house WLan
Scope of supply
- Manual
- mXion LSS-RhB
Hook-Up
Install your device in compliance with the connecting diagrams in this manual.
The device is protected against shorts and excessive loads. However, in case
of a connection error e.g. a short this safety feature can’t work and the
device will be destroyed subsequently.
Make sure that there is no short circuit caused by the mounting screws or
metal.
Connectors
- This typical switch signal is for everyone RhB, swiss train company. It can due to the small dimensions optimally in the station area be accommodated. The signal works digitally as well as analog. Simply close the 2 cables to the track or a DC voltage source e.g. EPL®.
- Weatherproof : Cover the PCB with „Plastik70“.
Product description
The mXion LSS-RhB is a modern light signal or dwarf signal of the swiss
railways (e.g. also the RhB). Here these light signals are large quantities of
routes, switches and used next to the railway line for shunting as well as
free or hold. Exemplary true-to-scale RhB dwarf signal with integrated decoder
can prototypically “stop”, “drive” and also “drive with caution”.
The integrated decoder for analog and digital operation allows all images of
the signal
to be given in an exemplary way. In addition will be a series of switching and
additional functions allows, which are separately activated (e.g. automatic
switching back to timing when a train has passed).
Programming lock
To prevent accidental programming to prevent CV 15/16 one programming lock.
Only if CV 15 = CV 16 is a programming possible. Changing CV 16 changes
automatically also CV 15. With CV 7 = 16 can the programming lock reset.
STANDARD VALUE CV 15/16 = 165
Programming options
This decoder supports the following programming types: bitwise, POM and CV
read & write and register-mode and programming switch.
There will be no extra load for programming.
In POM (programming on main track) the programming lock is also supported. The
decoder can also be on the main track programmed without the other decoder to
be influenced. Thus, when programming the decoder can not be removed.
NOTE: To use POM without others decoder must affect your digital center
POM to specific decoder addresses (e.g. Massoth® control panels)
Programming binary values
Some CV’s (e.g. 29) consist of so-called binary values. The means that several
settings in a value. Each function has a bit position and a value. For
programming such a CV must have all the significances can be added. A disabled
function has always the value 0.
EXAMPLE: You want 28 drive steps and long loco address. To do this, you
must set the value in CV 29 2 + 32 = 34 programmed.
Programming switch address
Switch addresses consist of 2 values.
For addresses < 256 the value can be directly in address low. The high address
is 0. If the address is > 255 this is as follows (for example address 2000):
- 2000 / 256 = 7,81, address high is 7
- 2000 – (7 x 256) = 208, address low is then 208.
Reset functions
The decoder can be reset via CV 7. Various areas can be used for this purpose.
Write with the following values:
- 11 (basic functions)
- 16 (programming lock CV 15/16)
- 33 (switch outputs)
CV-Table
S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable
CV | Description | S | L/S | Range | Note |
---|---|---|---|---|---|
7 | Software version | – | – | read only (10 = 1.1) | |
7 | Decoder reset functions | ||||
3 ranges available | 11 |
16
33| basic settings (CV 1,11-13,17-19,29-119) programming lock (CV 15/16)
switch outputs (from CV 120)
8| Manufacturer ID| 160| | –| read only
7+8| Register programming mode
Reg8 = CV-Address Reg7 = CV-Value| | | | CV 7/8 don’t changes his real value
CV 8 write first with cv-number, then CV 7 write with value or read (e.g.: CV
49 should have 3)
è CV 8 = 49, CV 7 = 3 writing
15| Programming lock (key)| 215| LS| 0 – 255| to lock only change this value
16| Programming lock (lock)| 215| LS| 0 – 255| changes in CV 16 will change CV
15
48| Switch address calculation| 0| S| 0/1| 0 = Switch address like norm
1 = Switch address like Roco, Fleischmann
49| mXion configuration| 0| S| | bitwise programming
Bit| Value| OFF (Value 0)| ON
0| 1| stop/drive normal function| stop/drive invert function
4| 16| stop/caution normal function| stop/caution invert function
6| 64| not save position| save position
118| Automatic switch back function to last state| 0| S| 0 – 255| 0 = off
1 – 255 = time base 0,25 sec. each Value
120| Stop/go address low| 0| W| 1 – 2048| Switching address, if address is
less than 256 simply CV121 = desired address!
121| Stop/go address high| 1| W
122| dimming value| 100| W| 1 – 100| Dimming value in % (1% approx. 0.2 V)
125| Stop/go w. caution address low| 0| W| 1 – 2048| Switching address, if
address is less than 256 simply CV126 = desired address!
126| Stop/go w. caution address high| 2| W
127| dimming value| 100| W| 1 – 100| Dimming value in % (1% approx. 0.2 V)
Technical data
-
Power supply: 7-27V DC/DCC
5-18V AC -
Current: 5mA (with out functions)
-
Maximum function current:
- LSS 0.1 Amps.
-
Maximum current: 0.2 Amps.
-
Temperature range: -20 up to 85°C
-
Dimensions LBH (cm): 2.52.71
NOTE: In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of condensed water. During operation is sufficient to prevent condensed water.
Warranty, Service, Support
micron-dynamics warrants this product against defects in materials and
workmanship for one year from the original date of purchase. Other countries
might have different legal warranty situations. Normal wear and tear, consumer
modifications as well as improper use or installation are not covered.
Peripheral component damage is not covered by this warranty. Valid warrants
claims will be serviced without charge within the warranty period. For
warranty service please return the product to the manufacturer. Return
shipping charges are not covered by micron-dynamics. Please include your proof
of purchase with the returned good. Please check our website for up to date
brochures, product information, documentation and software updates. Software
updates you can do with our updater or you can send us the product, we update
for you free.
Errors and changes excepted.
Hotline
For technical support and schematics for application examples contact:
micron-dynamics
info@micron-dynamics.de
service@micron-dynamics.de
www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>