mXion DFM Realistic Fire Module User Manual

June 3, 2024
mXion

DFM Realistic Fire Module
User ManualmXion DFM Realistic Fire Module - Figure
1

Introduction

Dear customer, we strongly recommend that you read these manuals and the warning notes thouroughly before installing and operating your device. The device is not a toy  (15+).
NOTE: Make sure that the outputs are set to appropriate value before hooking up any other device. We can’t be responsible For any damage if this is disregarded.

General information

We recommend studying this manual thoroughly before installing and operating your new device.
Place the decoder in a protected location.
The unit must not be exposed to moisture.
NOTE: Some funktions are only available with the latest firmware. Please make sure that your device is programmed with the latest firmware.

Summary of Funktions

DC/AC/DCC operation
Analog & digital
Every voltage usable
Also connectable to a decoder output
Compatible NMRA-DCC module
Very small module
Reset function for all CV values
Easy function mapping
Glow, wood and coal simulation (in digital)
28 function keys programmable, 10239 loco 14, 28, 128 speed steps (automaticly)
Switch, loco or with analog controllable
8 conditions possible (drive, stand, etc…)
Multiple programming options
(Bitwise, CV, POM accessoire decoder, register)
Needs no programming load

Scope of supply

Manual
mXion DFM

Hook-Up
Install your device in compliance with the connecting diagrams in this manual.
The device is protected against shorts and excessive loads. However, in case of a connection error e.g. a short this safety feature can’t work and the device will be destroyed  subsequently.
Make sure that there is no short circuit caused by the mounting screws or metal.
NOTE: Please note the CV basic settings in the delivery state.

Connectors DFM

Board color is black, fotos shown prototype
5 POWER-LEDs (red, orange, yellow) for realistic fire

mXion DFM Realistic Fire Module - Figure 2

Product description

The mXion DFM is an universal one fire module with real realistic fire for analogue and digital operation.
In digital mode are also still div. options and settings available.
So, in addition tot he controller over turnout or loco adresses too. The control over one random generator done. Via CV49 you can choose between wood/coal firing or oil  firing be switched. There is also the possibility of a glut simulation too.
These functions go also in analog mode.
It’s also possible to connect to an existing decoder.
Due to the small dimensions fits the module behind each boiler one track G locomotive as it not only very small but also extremely flat. It can, however place in a campfire or  around other applications find fire simulation space.
It’s possible to connect a buffer as well.

Programming lock

To prevent accidental programming to prevent CV 15/16 one programming lock. Only if CV 15 = CV 16 is a programming possible. Changing CV 16 changes automatically  also CV 15. With CV 7 = 16 can the programming lock reset.
STANDARD VALUE CV 15/16 = 200 Programming options
This decoder supports the following programming types: bitwise, POM and CV read & write and register-mode.
There will be no extra load for programming.
In POM (programming on maintrack) the programming lock is also supported.
The decoder can also be on the main track programmed without the other decoder to be influenced. Thus, when programming the decoder can not be removed.
NOTE: To use POM without others decoder must affect your digital center POM to specific decoder adresses

Programming binary values

Some CV’s (e.g. 29) consist of so-called binary values. The means that several settings in a value. Each function has a bit position and a value. For programming such a CV  must have all the significances can be added. A disabled function has always the value 0.
EXAMPLE: You want 28 drive steps and long loco address. To do this, you must set the value in CV 29 2 + 32 = 34 programmed.
Programming switch adress Switch addresses consist of 2 values.
For addresses < 256 the value can be directly in address low. The high address is 0. If the address is > 255 this is as follows (for example address 2000):
2000 / 256 = 7,81, address high is 7
2000 – (7 x 256) = 208, address low is then 208.
Programm these values into the switch CVs CV120/121.

Programming loco adress
Locomotives up to 127 are programmed directly to CV 1. For this, you need CV 29 Bit 5 „off“ (will set automaticly).
If larger addresses are used, CV 29 – Bit 5 must be „on“ (automaticly if change CV 17/18). The address is now in CV 17 and CV 18 stored. The address is then like follows  (e.g. loco address 3000):
3000 / 256 = 11,72; CV 17 is 192 + 11 = 203.
3000 – (11 x 256) = 184; CV 18 is then 184.
Reset functions
The decoder can be reset via CV 7. Various areas can be used for this purpose.
Write with the following values: 11 (basic functions) 16 (programming lock CV 15/16) 33 (function and switch outputs)

mXion DFM Realistic Fire Module - Figure 3mXion
DFM Realistic Fire Module - Figure 4

Technical data

Power supply:
5-27V DC/DCC
5-22V AC
Current:
5mA (with out functions)
Maximum current:
30 mAmps.
Temperature range:
-20 up to 65°C
Dimensions LBH (cm):
2.71.50.5
NOTE: In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of  condensed water. During operation is sufficient to prevent condensed water.

Warranty, Service, Support
micron-dynamics warrants this product against defects in materials and workmanship for one year from the original date of purchase. Other countries might have different  legal warranty situations. Normal wear and tear, consumer modifications as well as improper use or installation are not covered.
Peripheral component damage is not covered by this warranty. Valid warrants claims will be serviced without charge within the warranty period. For warranty service please  return the product to the manufacturer. Return shipping charges are not covered by micron-dynamics. Please include your proof of purchase with the returned good. Please  check our website for up to date brochures, product information, documentation and software updates. Software updates you can do with our updater or you can send us  the product, we update for you free.
Errors and changes excepted.
Hotline
For technical support and schematics for
application examples contact:
micron-dynamics
info@micron-dynamics.de
service@micron-dynamics.de

www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals