mXion DFM Realistic Fire Module User Manual
- June 3, 2024
- mXion
Table of Contents
DFM Realistic Fire Module
User Manual
Introduction
Dear customer, we strongly recommend that you read these manuals and the
warning notes thouroughly before installing and operating your device. The
device is not a toy (15+).
NOTE: Make sure that the outputs are set to appropriate value before
hooking up any other device. We can’t be responsible For any damage if this is
disregarded.
General information
We recommend studying this manual thoroughly before installing and operating
your new device.
Place the decoder in a protected location.
The unit must not be exposed to moisture.
NOTE: Some funktions are only available with the latest firmware. Please
make sure that your device is programmed with the latest firmware.
Summary of Funktions
DC/AC/DCC operation
Analog & digital
Every voltage usable
Also connectable to a decoder output
Compatible NMRA-DCC module
Very small module
Reset function for all CV values
Easy function mapping
Glow, wood and coal simulation (in digital)
28 function keys programmable, 10239 loco 14, 28, 128 speed steps
(automaticly)
Switch, loco or with analog controllable
8 conditions possible (drive, stand, etc…)
Multiple programming options
(Bitwise, CV, POM accessoire decoder, register)
Needs no programming load
Scope of supply
Manual
mXion DFM
Hook-Up
Install your device in compliance with the connecting diagrams in this manual.
The device is protected against shorts and excessive loads. However, in case
of a connection error e.g. a short this safety feature can’t work and the
device will be destroyed subsequently.
Make sure that there is no short circuit caused by the mounting screws or
metal.
NOTE: Please note the CV basic settings in the delivery state.
Connectors DFM
Board color is black, fotos shown prototype
5 POWER-LEDs (red, orange, yellow) for realistic fire
Product description
The mXion DFM is an universal one fire module with real realistic fire for
analogue and digital operation.
In digital mode are also still div. options and settings available.
So, in addition tot he controller over turnout or loco adresses too. The
control over one random generator done. Via CV49 you can choose between
wood/coal firing or oil firing be switched. There is also the possibility of
a glut simulation too.
These functions go also in analog mode.
It’s also possible to connect to an existing decoder.
Due to the small dimensions fits the module behind each boiler one track G
locomotive as it not only very small but also extremely flat. It can, however
place in a campfire or around other applications find fire simulation space.
It’s possible to connect a buffer as well.
Programming lock
To prevent accidental programming to prevent CV 15/16 one programming lock.
Only if CV 15 = CV 16 is a programming possible. Changing CV 16 changes
automatically also CV 15. With CV 7 = 16 can the programming lock reset.
STANDARD VALUE CV 15/16 = 200 Programming options
This decoder supports the following programming types: bitwise, POM and CV
read & write and register-mode.
There will be no extra load for programming.
In POM (programming on maintrack) the programming lock is also supported.
The decoder can also be on the main track programmed without the other decoder
to be influenced. Thus, when programming the decoder can not be removed.
NOTE: To use POM without others decoder must affect your digital center
POM to specific decoder adresses
Programming binary values
Some CV’s (e.g. 29) consist of so-called binary values. The means that several
settings in a value. Each function has a bit position and a value. For
programming such a CV must have all the significances can be added. A
disabled function has always the value 0.
EXAMPLE: You want 28 drive steps and long loco address. To do this, you must
set the value in CV 29 2 + 32 = 34 programmed.
Programming switch adress Switch addresses consist of 2 values.
For addresses < 256 the value can be directly in address low. The high address
is 0. If the address is > 255 this is as follows (for example address 2000):
2000 / 256 = 7,81, address high is 7
2000 – (7 x 256) = 208, address low is then 208.
Programm these values into the switch CVs CV120/121.
Programming loco adress
Locomotives up to 127 are programmed directly to CV 1. For this, you need CV
29 Bit 5 „off“ (will set automaticly).
If larger addresses are used, CV 29 – Bit 5 must be „on“ (automaticly if
change CV 17/18). The address is now in CV 17 and CV 18 stored. The address is
then like follows (e.g. loco address 3000):
3000 / 256 = 11,72; CV 17 is 192 + 11 = 203.
3000 – (11 x 256) = 184; CV 18 is then 184.
Reset functions
The decoder can be reset via CV 7. Various areas can be used for this purpose.
Write with the following values: 11 (basic functions) 16 (programming lock CV
15/16) 33 (function and switch outputs)
Technical data
Power supply:
5-27V DC/DCC
5-22V AC
Current:
5mA (with out functions)
Maximum current:
30 mAmps.
Temperature range:
-20 up to 65°C
Dimensions LBH (cm):
2.71.50.5
NOTE: In case you intend to utilize this device below freezing
temperatures, make sure it was stored in a heated environment before operation
to prevent the generation of condensed water. During operation is sufficient
to prevent condensed water.
Warranty, Service, Support
micron-dynamics warrants this product against defects in materials and
workmanship for one year from the original date of purchase. Other countries
might have different legal warranty situations. Normal wear and tear,
consumer modifications as well as improper use or installation are not
covered.
Peripheral component damage is not covered by this warranty. Valid warrants
claims will be serviced without charge within the warranty period. For
warranty service please return the product to the manufacturer. Return
shipping charges are not covered by micron-dynamics. Please include your proof
of purchase with the returned good. Please check our website for up to date
brochures, product information, documentation and software updates. Software
updates you can do with our updater or you can send us the product, we update
for you free.
Errors and changes excepted.
Hotline
For technical support and schematics for
application examples contact:
micron-dynamics
info@micron-dynamics.de
service@micron-dynamics.de
www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>