mxion KLI Spin Module User Manual

June 3, 2024
mXion

mxion KLI Spin Module

KLI Spin Module

Introduction

Dear customer, we strongly recommend that you read these manuals and the warning notes thoroughly before installing and operating your device. The device is not a toy (15+).
NOTE : Make sure that the outputs are set to appropriate value before hooking up any other device. We can’t be responsible For any damage if this is disregarded.

General information

We recommend studying this manual thoroughly before installing and operating your new device. Place the decoder in a protected location. The unit must not be exposed to moisture.
NOTE : Some funktions are only available with the latest firmware. Please make sure that your device is programmed with the latest firmware.

Summary of Funktions

  • DC/AC/DCC/PWM/ANALOG operation
  • 2 separate function inputs
  • 2 function outputs switchable with K1, K2
  • Switching amplifier usable
  • Fire imitation modul usable
  • Sirene light imitation modul usable
  • Railroad crossing sign lighting usable
  • Petroleum imitation modul usable
  • Fluorescent imitation modul usable
  • Mode set via dip switches
  • Robust, simple screw clamp

Scope of supply

  • Manual
  • mXion KLI

Hook-Up

Install your device in compliance with the connecting diagrams in this manual. The device is protected against shorts and excessive loads. However, in case of a connection error e.g. a short this safety feature can’t work and the device will be destroyed subsequently.
Make sure that there is no short circuit caused by the mounting screws or metal.

Connectors

Switch consumption between A1 and + or A2 and +. By connecting K1 and ­ or K2 and ­ can the associated output be switched.

Connectors

Example Petroleum/Neon

  • NEON: 1 = OFF, 2 = ON
  • PETROLEUM: 1 = 2 = OFF
    Example Petroleum/Neon

Example Blue-Light-Simulation

  • With K2 the simulation can be switched.
  • K1 must NOT be interconnected.
  • Use blue LEDs.
  • 1 = ON, 2 = OFF

Example Railroadcrossinglights

  • With K1+K2 the simulation can be switched.
  • Use red LEDs.
  • 1 = ON, 2 = OFF

Example Fire

  • With K1 the simulation can be switched.
  • K2 must NOT be interconnected.
  • Use a orange and a red LED.
  • 1 = ON, 2 = OFF
    Example Fire

Example Amplifier (Steam unit)

  • With K1 switch A1, K2 switch A2.
  • Ideal to switch un-reinforced outputs.
  • 1 = 2 = ON
    Example Amplifier \(Steam unit\)

Product description

The mXion KLI is a versatile module. It is used to simulate on fire, neon tubes (start flicker), blue lights and cross or crossing gates lighting, kerosene lamps and simulate can be used as amplifier. The mode is selected via DIP switch (red) on the board.

The exception this forms the fire mode. He is again in 3 other modes divied; these are as follows: Turn the DIP on fire mode (DIP1 ON/DIP2 OFF). Then you can:

Fire mode enables with K1, not use K2
Blue light mode enables with K2, not use K1
Crossing lights enables with K1+K2 simultan.

Ks switches general to ground (- pole). A1,2 switches synchronously with K1,2 and to ground. + Pole is the common counter contact.

The crossing light mode is ideal for unlimited transitions with the typical flash equip. To this end, you can optionally each side 1 red light connecting or 2 red lights.
For this mode, both must be connected IN and the mode on fire selected.

As switching amplifier, this module can also be used will. Unlike the other modes, where something is simulated, the input IN switches directly, without delay or simulation, the output OUT. This mode is suitable to a unreinforced swithing output (eg a decoder) high loads up to 1,5A to switch per output. So you can for example evaporators, motors, etc… turn without similar to switching decoder to destroy or to weigh heavily.

Application examples

The examples shown here serve only excite.

  • imitation of light (petroleum, neon) in locomotives, cars, buildings and much more
  • lamp simulation petroleum e.g. for the headlights of the steam locomotive
  • fire simulation (camp fire, boiler fire)
  • blue light simulations (ambulance, police)
  • railroad crossing light control
  • switching amplifier by a weak simply amplify the decoder output
  • easy handling with screw clamp
  • in combination with the TLSpro automatically switchable via brightness (e.g. neon simulation in building in darkness switch automatically on/off)

Technical data

Power supply:
7-27V DC/DCC/PWM (peaks max. 28V) 5-20V AC

Current:
1mA (with out functions)

Maximum function current:
A1 1 Amps.
A2 1 Amps.

Maximum current consumption
2 Amps.

Temperature range:
-20 up to 85°C

Modus :
DIP1 OFF/DIP2 OFF |Oil lamps
DIP1 OFF/DIP2 ON |Fluorescent lamp
DIP1 ON/DIP2 OFF |Fire/Sirene/Railway lights
DIP1 ON/DIP2 ON |Switching amplifier

Dimensions LBH (cm):
2.72.31

NOTE : In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of condensed water. During operation is sufficient to prevent condensed water.

Warranty, Service, Support

micron-dynamics warrants this product against defects in materials and workmanship for one year from the original date of purchase. Other countries might have different legal warranty situations. Normal wear and tear, consumer modifications as well as improper use or installation are not covered. Peripheral component damage is not covered by this warranty. Valid warrants claims will be serviced without charge within the warranty period. For warranty service please return the product to the manufacturer. Return shipping charges are not covered by micron-dynamics. Please include your proof of purchase with the returned good. Please check our website for up to date brochures, product information, documentation and software updates. Software updates you can do with our updater or you can send us the product, we update for you free.
Errors and changes excepted.

Hotline

For technical support and schematics for application examples contact:

micron-dynamics

info@micron-dynamics.de
service@micron-dynamics.de

Customer Support

www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics

mxion  Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals